Permit Application Status

PRRES20152440


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20152440
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - 2 STORY - UNFINISHED BASEMENT *ROOF & FLOOR TRUSS
10/20/2015
10/27/2015
01/03/2017
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/27/2015
James Fletchall
Plot Plan Review (P&D) Approved 10/27/2015
Ron Seyl
Residential Plan Review Approved 10/22/2015 10/21/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,017.60 $1,017.60 Paid 10/27/2015
Right of Way Permit Fee $75.00 $75.00 Paid 10/27/2015
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/27/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 10/27/2015
Water Meter Fee $377.18 $377.18 Paid 10/27/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 11/9/2015 (1:30) 11/9/2015 at 12:00 AM 11/09/2015
Misc
Corrective Action Required
11/09/2015
PLANS DO NOT SHOW USE OF HELIX AS A SUBSTITUTION FOR STEEL IN FOOTING OR FOUNDATION
Sewer Service Inspection - R Passed 11/24/2015 (1:15) 11/24/2015 at 12:00 AM 11/24/2015
Water Service Inspection - R Partial 11/24/2015 at 12:00 AM 11/24/2015
Water Service Inspection - R Passed 11/25/2015 at 12:00 AM 11/25/2015
Underslab Plumbing Inspection - Residential Not Ready 12/1/2015 at 12:00 AM 12/01/2015
Misc
Corrective Action Required
12/01/2015
REQUESTED INSPECTION DENIED DUE TO INCORRECT PLUMBING SUB-CONTRACTOR LISTED ON PERMIT.
Underslab Plumbing Inspection - Residential Passed 12/16/2015 12/16/2015 12/16/2015
Misc
Corrective Action Required
12/01/2015
REQUESTED INSPECTION DENIED DUE TO INCORRECT PLUMBING SUB-CONTRACTOR LISTED ON PERMIT.
Driveway Inspection Partial 3/21/2016 at 1:00 AM 03/21/2016
All Rough Inspection - Residential Failed 3/23/2016 3/23/2016 at 12:00 AM 03/23/2016
Misc
Corrective Action Required
03/23/2016
FIREBLOCK TO ISOLATE VERTICAL CAVITIES FROM HORIZONTAL CAVITIES: - TOPS OF VERTICAL CHASES AT 1) HOUSE-TO-GARAGE INTERFACE 2) ADJACENT TO LAUNDRY - WALL CAVITY AT WEST END OF MASTER BATH TUB
Misc
Corrective Action Required
03/23/2016
BROKEN WEB ON TRUSS AT TOP OF STAIR TO 2ND FLOOR
Misc
Corrective Action Required
03/23/2016
SOME STUD SHOES NOT FASTENED PER MANUFACTURER INSTRUCTIONS. ENSURE ALL FASTENER HOLES ARE USED AND ALL NAILS ARE FULLY DRIVEN.
Misc
Partial Correction
03/23/2016
OK TO INSULATE
Electrical Service Inspection Passed 3/23/2016 3/23/2016 03/23/2016
Gas Piping Inspection - Residential Passed 3/23/2016 03/23/2016
Gas Service Inspection - Residential Passed 3/23/2016 3/23/2016 03/23/2016
Driveway Inspection Passed 3/25/2016 03/25/2016
All Rough Inspection - Residential Failed 4/1/2016 4/1/2016 04/01/2016
Misc
Corrective Action Required
03/23/2016
FIREBLOCK TO ISOLATE VERTICAL CAVITIES FROM HORIZONTAL CAVITIES: - TOPS OF VERTICAL CHASES AT 1) HOUSE-TO-GARAGE INTERFACE 2) ADJACENT TO LAUNDRY - WALL CAVITY AT WEST END OF MASTER BATH TUB
Misc
Resolved
04/01/2016
BROKEN WEB ON TRUSS AT TOP OF STAIR TO 2ND FLOOR
Misc
Corrective Action Required
03/23/2016
SOME STUD SHOES NOT FASTENED PER MANUFACTURER INSTRUCTIONS. ENSURE ALL FASTENER HOLES ARE USED AND ALL NAILS ARE FULLY DRIVEN.
Misc
Partial Correction
03/23/2016
OK TO INSULATE
Erosion Control Inspection Residential Failed 4/1/2016 04/01/2016
Misc
Corrective Action Required
04/01/2016
FULLY RESTORE EROSION CONTROL AT CURB LINE. APPROVAL REQUIRED BEFORE NEXT ALL-ROUGH RE-INSPECTION.
All Rough Inspection - Residential Passed 4/6/2016 4/6/2016 04/06/2016
Misc
Resolved
04/06/2016
FIREBLOCK TO ISOLATE VERTICAL CAVITIES FROM HORIZONTAL CAVITIES: - TOPS OF VERTICAL CHASES AT 1) HOUSE-TO-GARAGE INTERFACE 2) ADJACENT TO LAUNDRY - WALL CAVITY AT WEST END OF MASTER BATH TUB
Misc
Resolved
04/06/2016
SOME STUD SHOES NOT FASTENED PER MANUFACTURER INSTRUCTIONS. ENSURE ALL FASTENER HOLES ARE USED AND ALL NAILS ARE FULLY DRIVEN.
Misc
Resolved
04/06/2016
OK TO INSULATE
Investigation Inspection Complete 10/3/2016 10/03/2016
Occupancy Inspection - Codes Residential Failed 12/29/2016 12/29/2016 12/29/2016
Misc
Corrective Action Required
12/29/2016
-INSTALL SECURITY SCREWS REAR DOOR -INSTALL GARGAGE DOOR CLOSER
Occupancy Inspection - Codes Residential Full C of O 1/3/2017 1/3/2017 01/03/2017
Misc
Resolved
01/03/2017
-INSTALL SECURITY SCREWS REAR DOOR -INSTALL GARGAGE DOOR CLOSER
Documents & Images
Date Uploaded File Type Document Name
10/27/2015 Letter Codes Building Permit
10/27/2015 Receipt Receipt for transaction: 2015-005927
10/27/2015 Plot Plan DOC102715-006
11/09/2015 Letter Inspection Summary
11/24/2015 Letter Inspection Summary
12/16/2015 Letter Inspection Summary
03/23/2016 Letter Inspection Summary
03/31/2016 Engineer Report/Study DOC033116-001
04/01/2016 Letter Inspection Summary
04/06/2016 Letter Inspection Summary
12/29/2016 Letter Inspection Summary
01/03/2017 Letter Field Certificate of Occupancy
01/04/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home