Permit Application Status

PRRES20151681


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20151681
Building Permit - Residential
Final Completion
SUMMIT CUSTOM HOMES LLC
ALTERATION SINGLE FAMILY
FINISHING BASEMENT *NEW HOME OWNERS DOING THE WORK (ONWER NAMES - KEITH AND JENNIFER MIKULICH) PHONE NUMBER: 816.886.2094
07/24/2015
07/24/2015
11/23/2015
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST  
KEITH & JENNIFER MIKULICH, Address:1312 NE ERNEST WAY  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 07/24/2015 07/24/2015
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Add/Alter Single Family $89.57 $89.57 Paid 07/24/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 8/28/2015 8/28/2015 at 12:00 AM 08/28/2015
All Rough Inspection - Residential Failed 9/11/2015 9/11/2015 at 12:00 AM 09/11/2015
Misc
Corrective Action Required
09/11/2015
-FIREBLOCKING THROUGHOUT: FB ALL WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); FB WALL VERTICALLY EVERY 10 FT -PROTECT PVC AT BEDROOM AND BATH ROOM BOTTOM WALL PLATES WITH BOCA PLATES -PROTECT WIRING NEAR CEILING AT STAIR WALL -INSTALL A CO/SMOKE DETECTOR OUTSIDE BEDROOM -INSTALL A RECEPTACLE INSIDE THE MECHANICAL RM -INSTALL A SEPARATE CIRCUIT FOR THE BATHROOM RECEPTACLE -COMPLETE WIRING MAKEUP INSIDE ALL BOXES. TIE ALL THE EQUIPMENT GROUNDING CONDUCTORS TOGETHER WITH WIRE NUTS. LEAVE OUT MIN. 6" PIGTAILS TO BOND SWITCHES&RECEPTACLES
All Rough Inspection - Residential Passed 9/16/2015 9/16/2015 at 12:00 AM 09/16/2015
Misc
Resolved
09/16/2015
-FIREBLOCKING THROUGHOUT: FB ALL WALL SPACE FROM CEILING SPACE (JOIST AND FURRED-DOWN SPACE); FB WALL VERTICALLY EVERY 10 FT -PROTECT PVC AT BEDROOM AND BATH ROOM BOTTOM WALL PLATES WITH BOCA PLATES -PROTECT WIRING NEAR CEILING AT STAIR WALL -INSTALL A CO/SMOKE DETECTOR OUTSIDE BEDROOM -INSTALL A RECEPTACLE INSIDE THE MECHANICAL RM -INSTALL A SEPARATE CIRCUIT FOR THE BATHROOM RECEPTACLE -COMPLETE WIRING MAKEUP INSIDE ALL BOXES. TIE ALL THE EQUIPMENT GROUNDING CONDUCTORS TOGETHER WITH WIRE NUTS. LEAVE OUT MIN. 6" PIGTAILS TO BOND SWITCHES&RECEPTACLES
Final Inspection - Residential Passed 11/23/2015 11/23/2015 at 12:00 AM 11/23/2015
Documents & Images
Date Uploaded File Type Document Name
07/24/2015 Letter Codes Building Permit
07/24/2015 Receipt Receipt for transaction: 2015-004340
07/27/2015 Plans DOC072715-002
08/28/2015 Letter Inspection Summary
09/11/2015 Letter Inspection Summary
09/16/2015 Letter Inspection Summary
11/23/2015 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home