Permit Application Status

PRRES20151563


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20151563
Building Permit - Residential
Final Completion
PARRISH JOHN EDWARD & CLAUDIA B
ALTERATION SINGLE FAMILY
PARTIAL HOUSE REMODEL MASTER BEDROOM, MASTER BATH, KITCHEN NO HVAC
07/14/2015
07/20/2015
12/11/2015
Locations
Contacts
WEST CENTRAL CONSTRUCTION, Address:304 NW CENTRAL ST, Phone:(816) 774-1016  
TAYLOR ELECTRIC INC, Address:6001 W 101ST STREET, Phone:(913) 530-6447  
ALLIANCE PLUMBING, Address:2500 TWIN OAKS DR, Phone:(816) 716-2249  
PARRISH JOHN EDWARD & CLAUDIA B, Address:PO BOX 469  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 07/14/2015 07/20/2015
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Add/Alter Single Family $106.48 $106.48 Paid 07/20/2015
8331507-Sewer Connection Fee $90.00 $90.00 Paid 07/20/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 8/7/2015 8/7/2015 at 12:00 AM 08/07/2015
Misc
Corrective Action Required
08/07/2015
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
08/07/2015
IRC R502.13; R602.8: IN WOOD-FRAMED STRUCTURE FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN TOP & BOTTOM PLATES, TOPS & BOTTOMS OF CHASES / DEAD SPACES, INTERFACES OF WALLS WITH FLOOR/CEILING/FUR-DOWN SPACES, HOLES IN FLOOR INCLUDING AT TUB, SHOWER, ETC.
All Rough Inspection - Residential Not Ready 8/11/2015 8/11/2015 at 12:00 AM 08/11/2015
Misc
Corrective Action Required
08/07/2015
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
08/07/2015
IRC R502.13; R602.8: IN WOOD-FRAMED STRUCTURE FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN TOP & BOTTOM PLATES, TOPS & BOTTOMS OF CHASES / DEAD SPACES, INTERFACES OF WALLS WITH FLOOR/CEILING/FUR-DOWN SPACES, HOLES IN FLOOR INCLUDING AT TUB, SHOWER, ETC.
All Rough Inspection - Residential Partial 8/13/2015 8/13/2015 at 12:00 AM 08/13/2015
Misc
Resolved
08/13/2015
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Partial Correction
08/13/2015
COMPLETE FIRE-BLOCKING OF TOP PLATE BORES AT BTHROOMS. THEN OK TO COVER WALLS AND CEILINGS AT BEDROOM AND BATHROOMS. KITCHEN NOT READY FOR INSPECTION. IRC R502.13; R602.8: IN WOOD-FRAMED STRUCTURE FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS. ANY HOLES OR DISCONTINUITIES IN TOP & BOTTOM PLATES, TOPS & BOTTOMS OF CHASES / DEAD SPACES, INTERFACES OF WALLS WITH FLOOR/CEILING/FUR-DOWN SPACES, HOLES IN FLOOR INCLUDING AT TUB, SHOWER, ETC.
All Rough Inspection - Residential Partial 8/25/2015 at 12:00 AM 08/25/2015
Final Inspection - Residential Not Ready 11/9/2015 11/9/2015 at 12:00 AM 11/09/2015
Misc
Corrective Action Required
11/09/2015
IBC 110.1 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes.
All Rough Inspection - Residential Passed 8/25/2015 at 12:00 AM 11/09/2015
Final Inspection - Residential Passed 12/11/2015 12/11/2015 at 12:00 AM 12/11/2015
Misc
Resolved
12/11/2015
IBC 110.1 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes.
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit