Summary
PRRES20151229
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - FINISHED WALKOUT BASEMENT *ROOF TRUSSES
06/02/2015
06/10/2015
04/14/2016
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 06/09/2015 06/10/2015
Jennifer Thompson
Plot Plan Review Approved 06/10/2015 06/10/2015
James Fletchall
Plot Plan Review Rejected 06/08/2015
James Fletchall
Plot Plan Review (P&D) Rejected 06/05/2015
Jennifer Thompson
Residential Plan Review Approved 06/04/2015 06/02/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $807.52 $807.52 Paid 06/10/2015
Right of Way Permit Fee $75.00 $75.00 Paid 06/10/2015
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/10/2015
Water Tap Fee $3,198.00 $3,198.00 Paid 06/10/2015
Water Meter Fee $354.05 $354.05 Paid 06/10/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/29/2015 (1:30) 6/29/2015 at 12:00 AM 06/29/2015
Piers/Caissons Inspection - Residential Passed 6/29/2015 at 12:00 AM 06/29/2015
Sewer Service Inspection - R Passed 7/14/2015 (8:45) 7/14/2015 at 12:00 AM 07/14/2015
Water Service Inspection - R Partial 7/14/2015 at 12:00 AM 07/14/2015
Water Service Inspection - R Failed 7/15/2015 (1:30) 7/15/2015 at 12:00 AM 07/15/2015
Misc
Corrective Action Required
07/15/2015
WATER METER NOT SET. NO GRAVEL IN PIT.
Underslab Plumbing Inspection - Residential Passed 7/15/2015 7/15/2015 at 12:00 AM 07/15/2015
Water Service Inspection - R Passed 7/16/2015 (8:00) 7/16/2015 at 12:00 AM 07/16/2015
Misc
Resolved
07/16/2015
WATER METER NOT SET. NO GRAVEL IN PIT.
All Rough Inspection - Residential Failed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
Misc
Corrective Action Required
10/07/2015
-GARAGE PORTAL NOT NAILED 3" O.C. -INSTALL H CLIPS FOR TRUSSES BEARING ON GARAGE COLD WALL. -SEAL ALL PENETRATIONS BETWEEN FLOORS AND TO ATTIC. -NAIL GORDER TRUSS OVER KITCHEN PER PLAN. -PROTECT CONDUCTORS CORNERS OF FRONT FIRST FLOOR BEDROOM. -BRACE TRUSSES PER PLANS. -FIREBLOCK BASEMENT BACK WALL BY BAR. -STUD SHOES AT PLUMBING BASEMENT BACK WALL BY BAR. OKAY TO INSULATE
Gas Service Inspection - Residential Passed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
Electrical Service Inspection Passed 10/7/2015 10/7/2015 at 12:00 AM 10/07/2015
All Rough Inspection - Residential Failed 10/19/2015 10/19/2015 at 12:00 AM 10/19/2015
Misc
Corrective Action Required
10/07/2015
-INSTALL H CLIPS FOR TRUSSES BEARING ON GARAGE COLD WALL. -BRACE TRUSSES PER PLANS. -STUD SHOES AT PLUMBING BASEMENT BACK WAALL OKAY TO INSULATE
All Rough Inspection - Residential Passed 10/20/2015 10/20/2015 at 12:00 AM 10/20/2015
Misc
Resolved
10/20/2015
-INSTALL H CLIPS FOR TRUSSES BEARING ON GARAGE COLD WALL. -BRACE TRUSSES PER PLANS. -STUD SHOES AT PLUMBING BASEMENT BACK WAALL OKAY TO INSULATE
Sidewalk Inspection Passed 1/25/2016 01/26/2016
Plot Plan Inspection Passed 03/16/2016
Occupancy Inspection - Codes Residential Failed 3/16/2016 3/16/2016 03/16/2016
Misc
Corrective Action Required
03/16/2016
-RAISE WATER METER FLUSH WITH GRADE -INSTALL ATTIC ACCESS IN LID IN GARAGE -MOVE WINDOWS TO TEST RECEPTACLE IN GARAGE -INSTALL SECURITY SCREWS ALL REAR DOORS -MAX AC FUSE IS 40 AMP -TOP RISOR STAIRS EXCEEDS 3/8THS IN VARIANCE -INSTALL DECK HANDRAIL
Occupancy Inspection - Codes Residential Full C of O 4/14/2016 4/14/2016 04/14/2016
Misc
Resolved
04/14/2016
-INSTALL ATTIC ACCESS IN LID IN GARAGE -MOVE WINDOWS TO TEST RECEPTACLE IN GARAGE -INSTALL SECURITY SCREWS ALL REAR DOORS -MAX AC FUSE IS 40 AMP -TOP RISOR STAIRS EXCEEDS 3/8THS IN VARIANCE -INSTALL DECK HANDRAIL
Documents & Images
Date Uploaded File Type Document Name
06/10/2015 Receipt Receipt for transaction: 2015-002794
06/10/2015 Letter Codes Building Permit
06/11/2015 Plot Plan DOC061115-012
06/29/2015 Letter Inspection Summary
06/29/2015 Letter Inspection Summary
07/14/2015 Letter Inspection Summary
07/15/2015 Letter Inspection Summary
07/16/2015 Letter Inspection Summary
10/07/2015 Letter Inspection Summary
10/07/2015 Engineer Report/Study DOC100715-005
10/07/2015 Engineer Report/Study DOC100715-006
10/19/2015 Letter Inspection Summary
10/20/2015 Letter Inspection Summary
03/16/2016 Letter Inspection Summary
04/14/2016 Letter Field Certificate of Occupancy
04/15/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home