Summary
PRRES20150890
Building Permit - Residential
Certificate of Occupancy
RPWC HOLDINGS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED PATIO - UNFINISHED BASEMENT
04/27/2015
05/18/2015
10/24/2015
06/06/2016
Locations
Contacts
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
ROBERTSON PLUMBING LLC, Address:PO BOX 165, Phone:(816) 781-9340  
RPWC HOLDINGS LLC, Address:3170 NE CARNEGIE DR STE 400, Phone:(816) 795-8100  
HARMON MARYANN S, Address:3928 NE INDEPENDENCE AVE  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/20/2015 05/18/2015
Tara Mitchell
Plot Plan Review Approved 05/08/2015 05/08/2015
James Fletchall
Plot Plan Review Rejected 05/05/2015 05/06/2015
James Fletchall
Plot Plan Review Rejected 05/01/2015 05/01/2015
James Fletchall
Plot Plan Review (P&D) Approved 04/29/2015 04/30/2015
Christina Stanton
Plot Plan Review Rejected 04/29/2015
James Fletchall
Residential Plan Review Rejected 04/29/2015 04/27/2015
Tara Mitchell
Plot Plan Review (P&D) Rejected 04/27/2015
Christina Stanton
DE Corps of Engineers
Corrective Action Required
04/27/2015

Scale says 1" = 30', but it doesn't scale at that. It appears to scale at 1" = 20'.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $723.41 $723.41 Paid 05/18/2015
8331506-EFHB Maybrook, Full $553.93 $553.93 Paid 05/18/2015
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/18/2015
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/18/2015
8331401-Water Tap Fee $3,198.00 $3,198.00 Paid 05/18/2015
8350015-Water Meter Fee $354.05 $354.05 Paid 05/18/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 7/9/2015 (4:30) 7/9/2015 at 12:00 AM 07/09/2015
Misc
Corrective Action Required
07/09/2015
-ONLY THE BASEMENT FOOTING OK TO POUR. GARAGE FOOTING WILL BE DONE LATER -WALLS BETWEEN THIS HOUSE AND THE ONE ON THE SOUTH SIDE APPEAR TO BE LESS THAN TEN FT APART. CODE REQUIRES 1 HR RATING ON THE WALLS AND THE SOFFIT. PROVIDE MINIMUM TEN FT SEPARATION DISTANCE BETWEEN HOUSES
Footing Inspection - Residential Passed 7/10/2015 (10:15) 7/10/2015 at 12:00 AM 07/10/2015
Misc
Resolved
07/10/2015
-ONLY THE BASEMENT FOOTING OK TO POUR. GARAGE FOOTING WILL BE DONE LATER -WALLS BETWEEN THIS HOUSE AND THE ONE ON THE SOUTH SIDE APPEAR TO BE LESS THAN TEN FT APART. CODE REQUIRES 1 HR RATING ON THE WALLS AND THE SOFFIT. PROVIDE MINIMUM TEN FT SEPARATION DISTANCE BETWEEN HOUSES
Underslab Plumbing Inspection - Residential Passed 8/5/2015 8/4/2015 at 12:00 AM 08/04/2015
Piers/Caissons Inspection - Residential Passed 8/10/2015 (11:30) 8/10/2015 at 12:00 AM 08/10/2015
Gas Service Inspection - Residential Passed 10/8/2015 10/8/2015 at 12:00 AM 10/08/2015
Electrical Service Inspection Passed 10/8/2015 at 12:00 AM 10/08/2015
All Rough Inspection - Residential Failed 10/9/2015 10/8/2015 at 12:00 AM 10/08/2015
Misc
Corrective Action Required
10/08/2015
FRAMING: -HAVE PLAN ON SITE FOR REINSPECTION -SUPPORT HIP ABOVE MASTER CLOSET -THE PLUMBER NOTCHED THE BEAM ABOVE MASTER BATH SINK WALL. REPLACE OR HAVE ENGINEER ADDRESS -STRAP TOP PLATES LAPPED LESS THAN 24" MASTER BED -INSTALL RAFTER TIES AT 4FT INTERVAL ABOVE LIVING RM -SUPPORT HIP ABOVE LIVING RM (BOTH THE REGULAR LUMBER HIP AND THE LVL HIP) -BLOCK THE REAR DOOR STUDS AND FILL IN GAP AT STRIKE PLATE SIDE PER LS SECURITY CODE -COMPLETE FUR OUT FOR THE B-VENT AND FIREBLOCK FROM ATTIC -FIREBLOCK KITCHEN WALL AT REFRIGERATOR FROM ATTIC -SUPPORT THE BOTTOM OF LVL HIP TO CEILING BEAM AT NW BED -PROVIDE R-15 THERMAL ENVELOP AT GARAGE RETURN AIR MECHANICAL: -VENT ALL BATH FANS -CODES REQUIRES THAT THE RETURN AIR SPACE BE SEPARATED FROM THE OTHER SPACE (FIREPLACE) WITH APPROVED FIREBLOCKING MATERIAL. BLOCK OFF WITH 3/4" SHEATHING OR LUMBER OR PAN OFF (AND SEAL ANY GAP) RETURN AIR SPACE FROM THE FIREPLACE SPACE **OK TO INSULATE
Sewer Service Inspection - R Partial 10/26/2015 (2:00) 10/26/2015 at 12:00 AM 10/26/2015
Sewer Service Inspection - R Passed 10/28/2015 (9:30) 10/28/2015 at 12:00 AM 10/28/2015
Water Service Inspection - R Passed 10/29/2015 (1:00) 10/29/2015 at 12:00 AM 10/29/2015
All Rough Inspection - Residential Failed 11/2/2015 11/2/2015 at 12:00 AM 11/02/2015
Misc
Corrective Action Required
10/08/2015
FRAMING: -HAVE PLAN ON SITE FOR REINSPECTION -BLOCK THE REAR DOOR STUDS AND FILL IN GAP AT STRIKE PLATE SIDE PER LS SECURITY CODE **SHIM THE EXCESSIVE GAP -FIREBLOCK KITCHEN WALL AT REFRIGERATOR FROM ATTIC **NOT DONE -PROVIDE R-15 THERMAL ENVELOP AT GARAGE RETURN AIR **NEED THE R-15 THERMAL ENCELOPE FOR THE ENTIRE HEIGHT OF THE WALL **OK TO INSULATE
All Rough Inspection - Residential Passed 11/3/2015 11/3/2015 at 12:00 AM 11/03/2015
Misc
Resolved
11/03/2015
FRAMING: -HAVE PLAN ON SITE FOR REINSPECTION -BLOCK THE REAR DOOR STUDS AND FILL IN GAP AT STRIKE PLATE SIDE PER LS SECURITY CODE **SHIM THE EXCESSIVE GAP -FIREBLOCK KITCHEN WALL AT REFRIGERATOR FROM ATTIC **NOT DONE -PROVIDE R-15 THERMAL ENVELOP AT GARAGE RETURN AIR **NEED THE R-15 THERMAL ENCELOPE FOR THE ENTIRE HEIGHT OF THE WALL **OK TO INSULATE
Occupancy Inspection - Codes Residential Failed 1/19/2016 01/19/2016
Misc
Corrective Action Required
01/19/2016
-INSTALL SIDEWALK; DRIVEWAY NOT APPROVED ON RECORD -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL ABOVE METER AND FRONT LIGHTS -INSTALL GUARDRAIL AT STOOP WHERE MORE THAN 30" ABOVE GRADE -SCREW THE EMBEDDED METAL BRACE OF DECK DOOR INTO STUDS -FIREBLOCK FLOOR OPENING AT HYDRO TUB TRAP -GFCIs NOT TESTED AT THIS TIME
Sidewalk Inspection Passed 2/22/2016 02/23/2016
Occupancy Inspection - Codes Residential Temporary C of O 3/1/2016 3/1/2016 03/01/2016
Misc
Corrective Action Required
01/19/2016
-DRIVEWAY NOT APPROVED ON RECORD -FINAL GRADE, SOD, SPLASHBLOCKS -SCREW THE EMBEDDED METAL BRACE OF DECK DOOR INTO STUDS -FASTEN THE LADDER TO WINDOW WELL
Driveway Inspection Passed 03/02/2016
Occupancy Inspection - Codes Residential Full C of O 6/6/2016 06/06/2016
Misc
Resolved
06/06/2016
-SOD, SPLASHBLOCKS
Documents & Images
Date Uploaded File Type Document Name
05/18/2015 Letter Codes Building Permit
05/18/2015 Receipt Receipt for transaction: 2015-001382
05/19/2015 Plot Plan DOC051915-004
07/09/2015 Letter Inspection Summary
07/10/2015 Letter Inspection Summary
08/04/2015 Letter Inspection Summary
08/10/2015 Letter Inspection Summary
10/08/2015 Letter Inspection Summary
10/26/2015 Letter Inspection Summary
10/28/2015 Letter Inspection Summary
10/29/2015 Letter Inspection Summary
11/02/2015 Engineer Report/Study DOC110215
11/02/2015 Letter Inspection Summary
11/03/2015 Letter Inspection Summary
01/19/2016 Letter Inspection Summary
03/01/2016 Letter Codes Temporary Certificate of Occupancy
06/06/2016 Letter Field Certificate of Occupancy
06/07/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home