Permit Application Status

PRCOM20244483


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20244483
Building Permit - Commercial
Voided
HALLAM JAMES B & JOLENE I TRUSTEES
CHANGE OF TENANT
CHANGE OF TENANT TO EYE DOCTOR **voided per tenant - JOE FROGGE 01/21/2025 8:40 AM
08/23/2024
01/21/2025
Locations
Contacts
HALLAM JAMES B & JOLENE I TRUSTEES, Address:3996 SE DOC HENRY RD  
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CHRIS JEFFRIES, Address:JFE CONSTRUCTION, Phone:(816) 786-4008  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved 09/05/2024 09/09/2024
Craig Hill
Building Plan Review Rejected 09/05/2024 08/30/2024
Joe Frogge
NEC Article 517.13 Grounding of receptacles patient care
Corrective Action Required
08/30/2024

2017 NEC Article 517.13 Grounding of Receptacles and Fixed Electrical Equipment in Patient Care Spaces. Wiring in patient care spaces shall comply with 517.13(A) and (B). (A) Wiring methods. All branch circuits serving patient care spaces shall be provided with an effective ground-fault current path by installation in a metal raceway system, or a cable having a metallic armor or sheath assembly. The metal raceway system, metallic cable armor, or sheath assembly shall itself qualify as an equipment grounding conductor in accordance with 250.118. (B) Insulated Equipment Grounding Conductors and Insulated Equipment Bonding Jumpers. (1) General. The following shall be directly connected to an insulated copper equipment grounding conductor that is clearly identified along its entire length by green insulation and installed with the branch circuit conductors in the wiring methods as provided in 517.13(A). 1. The grounding terminals of all receptacles other than isolated ground receptacles. 2. Metal outlet boxes, metal device boxes, or metal enclosures. 3. All non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized that are subject to personal contact, operating at over 100 volts. (see code for exceptions) (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accordance with 250.122. Action required: Modify drawings to show that all circuits in patient care areas will have redundant ground system. Also, identify patient care areas.
Licensed Contractors Approved 09/05/2024 08/27/2024
Joe Frogge
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
08/23/2024 Application Form APPLICATION
08/23/2024 Plans Redline Tenant Finish Plans Godshall
09/06/2024 Letter License Tax Bill
09/09/2024 Letter DS P/R Corrections Document
01/21/2025 Email void
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home