Permit Application Status

PRCOM20240114


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20240114
Building Permit - Commercial
Certificate of Occupancy
RED SUMMIT FAIR LLC
CHANGE OF TENANT
CHANGE OF TENANT FOR STRETCH GYM FACILITY WITH SOME RETAIL
01/09/2024
01/29/2024
07/21/2024
02/20/2024
Locations
Contacts
RED SUMMIT FAIR LLC, Address:ONE E WASHINGTON ST STE 300  
JE DUNN CONSTRUCTION CO, Address:120 S CENTRAL AVE STE 350, Phone:(816) 474-8600  
SAVANNAH.PARRY@JEDUNN.COM  
WESTHUES ELECTRIC INC, Address:PO BOX 18220, Phone:(816) 356-5223  
PM CONTRACTING INC, Address:4015 E 143RD ST, Phone:(816) 318-9844  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 01/30/2024 01/26/2024
Joe Frogge
Portable fire extinguishers - general
Corrective Action Required
01/23/2024

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher if not already present. Verified at inpection.
Miscellaneous Correction
Corrective Action Required
01/23/2024

Relocate the emergency light and any alarm notification appliances that may be on the demo'd partition wall, to the south. Verified at inspection.
MISC
Corrective Action Required
01/23/2024

All reported existing conditions will be subject to inspection for code compliance.
Building Plan Review Approved 01/30/2024 01/26/2024
Joe Frogge
IBC 1209.2 Finish materials
Resolved
01/26/2024

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Modify drawings to demonstrate compliance at walls near toilets. If paint is used it must be epoxy based.
Code analysis required
Resolved
01/26/2024

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis.
Miscellaneous Correction
Resolved
01/26/2024

Inadequate information. Action required: Provide floor plan that shows complete final design with each room labelled for specific use.
IPC 403.1 Minimum number of fixtures
Resolved
01/26/2024

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide mop sink and drinking fountain.
Licensed Contractors Approved 01/30/2024 01/23/2024
Joe Frogge
Building Plan Review Rejected 01/19/2024 01/19/2024
Tracy Deister
IBC 1209.2 Finish materials
Corrective Action Required
01/12/2024

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Modify drawings to demonstrate compliance at walls near toilets. If paint is used it must be epoxy based.
Code analysis required
Corrective Action Required
01/12/2024

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis.
Miscellaneous Correction
Corrective Action Required
01/12/2024

Inadequate information. Action required: Provide floor plan that shows complete final design with each room labelled for specific use.
IPC 403.1 Minimum number of fixtures
Corrective Action Required
01/12/2024

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide mop sink and drinking fountain.
Fire Plan Review Approved with Conditions 01/22/2024 01/19/2024
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
01/19/2024

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher if not already present. Verified at inpection.
Miscellaneous Correction
Corrective Action Required
01/19/2024

Relocate the emergency light and any alarm notification appliances that may be on the demo'd partition wall, to the south. Verified at inspection.
MISC
Corrective Action Required
01/19/2024

All reported existing conditions will be subject to inspection for code compliance.
Licensed Contractors Approved 01/09/2024 01/09/2024
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $184.00 $184.00 Paid 01/29/2024
$8,415.00
7232302-Commercial Excise Tax Fee $4,207.50 $4,207.50 Paid 01/09/2024
$4,207.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 2/9/2024 2/9/2024 02/09/2024
Misc
Informational
02/09/2024
- PLUMBING FOR UTILITY SINK
Occupancy Inspection - Codes Commercial Full C of O 2/20/2024 2/20/2024 02/20/2024
Occupancy Inspection - Fire Passed 2/20/2024 2/20/2024 02/20/2024
Documents & Images
Date Uploaded File Type Document Name
01/09/2024 Application Form APPLICATION
01/09/2024 Plans StretchLabSummitFair - SP Copy REV2
01/09/2024 Letter AutoCAD release - signed
01/09/2024 Plans Salon Ami plans - Summit Fair
01/09/2024 Letter License Tax Bill
01/19/2024 Letter Fire Building Plan Review
01/23/2024 Letter DS P/R Corrections Document
01/23/2024 Plans StretchLabSummitFair - SP Copy REV3
01/26/2024 Approved Plans approved - StretchLabSummitFair - SP Copy REV3
01/29/2024 Receipt Receipt for transaction:2024-000427
01/29/2024 Letter DS Building Permit
02/09/2024 Letter INSPECTION SUMMARY
02/20/2024 Letter Codes Final Certificate of Occupancy
02/20/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home