Permit Application Status

PRCOM20235363


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20235363
Building Permit - Commercial
Final Completion
NEW OTHER (COMMERCIAL)
TRILOGY TEMP SERVICE ES3
10/17/2023
10/17/2023
11/13/2023
Locations
Contacts
NEIGHBORS CONSTRUCTION COMPANY INC, Address:1708 E 123RD ST, Phone:(913) 422-5555  
MTD Electric, LLC, Address:22004 S Waverly Rd  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 10/17/2023 10/17/2023
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Other $50.00 $50.00 Paid 10/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 10/18/2023 10/18/2023
Misc
Corrective Action Required
10/18/2023
-Provide supplemental ground rod 6' from ground rod per NEC250.53(A)(3) -Use conductors listed for underground service per NEC 230.30 -Provide bonding bushings at all metallic raceways connected to service enclosure through concentric knockouts -Provide dead fronts/ secure dead fronts at all service equipment -Screws not permitted through service enclosure -Provide listed clamps at all conductors entering panel -Seal all openings in receptacle boxes with approved means -Protect grounding electrode conductor from physical damage per NEC250.64 -Drive ground rods and connector to grade
Electrical Service Inspection Passed 11/9/2023 11/9/2023 11/09/2023
Misc
Resolved
11/09/2023
-Provide supplemental ground rod 6' from ground rod per NEC250.53(A)(3) -Use conductors listed for underground service per NEC 230.30 -Provide bonding bushings at all metallic raceways connected to service enclosure through concentric knockouts -Provide dead fronts/ secure dead fronts at all service equipment -Screws not permitted through service enclosure -Provide listed clamps at all conductors entering panel -Seal all openings in receptacle boxes with approved means -Protect grounding electrode conductor from physical damage per NEC250.64 -Drive ground rods and connector to grade
Documents & Images
Date Uploaded File Type Document Name
10/17/2023 Drawing Trilogy temp service locations
10/17/2023 Receipt Receipt for transaction:2023-007829
10/17/2023 Letter DS Building Permit
10/18/2023 Letter INSPECTION SUMMARY
11/09/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home