Permit Application Status

PRCOM20221180


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20221180
Building Permit - Commercial
Voided
PINE TREE PLAZA LLC
NEW OTHER (COMMERCIAL)
TRELLIS OVER EXTERIOR BBQ GRILLE AND COUNTER
03/29/2022
10/09/2022
04/03/2024
Locations
Contacts
  
Greg Hastie, Address:Greg@AmericanFireBBQ.com, Phone:(816) 805-2729  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit B, Phone:(816) 249-2270  
PINE TREE PLAZA LLC, Address:601 E SOUTH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Zoning Review Approved 04/12/2022 04/12/2022
Joe Frogge
Fire Plan Review Approved with Conditions 04/12/2022 04/12/2022
Jim Eden
Miscellaneous Correction
Corrective Action Required
04/12/2022

Comments 1,2,and 4 only apply if there is a smoker (solid fuel appliance) being used other than a pellet smoker.
Misc
Corrective Action Required
04/12/2022

NFPA 96- 14.9.3.8 Ash Removal Container or Cart. 14.9.3.8.1 A heavy metal container or cart (minimum 16 gauge) with a cover shall be provided for the removal of ash. 14.9.3.9.4 The ash shall be carried to a separate heavy metal container (or dumpster) used exclusively for the purpose. Verified at inspection.
Portable fire extinguishers - general
Corrective Action Required
04/12/2022

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide an ABC type fire extinguisher (2A:10B:C) within 35 feet of the cooking area. If there is one accesible inside the front door; that counts. Verified at inspection.
Miscellaneous Correction
Corrective Action Required
04/12/2022

NFPA 96 14.7.8 * All solid fuel appliances (whether under a hood or not) with fire boxes of 0.14 m3 (5 ft3) volume or less shall have at least a listed 2-A rated water spray fire extinguisher or a 6 L (1.6 gal) wet chemical fire extinguisher listed for Class K fires in accordance with NFPA 10, with a maximum travel distance of 6 m (20 ft) to the appliance. Hose Protection. 14.7.9.1 Solid fuel appliances with fireboxes exceeding 0.14 m3 (5 ft3) shall be provided with a fixed water pipe system with a hose in the kitchen capable of reaching the firebox. Provide the appropriate extinguishing appliance for the size of fire box. Verified at inspection.
Building Plan Review Rejected 04/12/2022 03/29/2022
Joe Frogge
Health Dept Review
Corrective Action Required
03/29/2022

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
03/29/2022

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
Licensed Contractors Rejected 04/12/2022 03/29/2022
Joe Frogge
LC - General Contractor
Corrective Action Required
03/29/2022

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact which is where inspection reports will be sent.
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
03/29/2022 Application Form Commercial Permit Application_AmericanFireBBQPatio
03/29/2022 Plans 21066_American Fire BBQ_210607_Sheet - A002 - Outdoor Parking Pavilion Concept Updated
03/29/2022 Plans structural
03/29/2022 Plans Patio Renderings
04/12/2022 approved designs
04/12/2022 Letter DS P/R Corrections Document
04/27/2022 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home