Permit Application Status

PRCOM20215277


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20215277
Building Permit - Commercial
Certificate of Occupancy
CHAPEL RIDGE TOWNHOMES LLC
NEW MULTI-FAMILY
NEW 4PLEX
10/08/2021
08/25/2022
06/19/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:4301 INDIAN CREEK PKWY, Phone:(913) 451-9390  
CHAPEL RIDGE TOWNHOMES LLC, Address:3701 NE AKIN DR  
TEG CHAPEL RIDGE LLC, Address:365 NY 59 STE 110  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/07/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $1,874.84 $1,874.84 Paid 08/24/2022
8331507-Sewer Connection Fee $1,320.00 $1,320.00 Paid 08/24/2022
7232302-Residential Excise Tax Fee $2,437.12 $2,437.12 Paid 08/24/2022
9110078-Valuation Fee for New 3 or 4 Family $2,251.12 $2,251.12 Paid 08/24/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/13/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 9/29/2022 (1:00) 9/29/2022 09/29/2022
Underslab Plumbing Inspection - Commercial Passed 10/7/2022 10/7/2022 10/07/2022
Rated Assembly Inspection Partial 12/20/2022 12/20/2022 12/20/2022
Misc
Corrective Action Required
12/20/2022
Attic firewall-1st layer ok
Electrical Service Inspection Passed 2/17/2023 2/17/2023 02/17/2023
Gas Service Inspection - Commercial Failed 2/17/2023 2/17/2023 02/17/2023
Misc
Corrective Action Required
02/17/2023
-Unit A has no pressure
All Rough Inspection - Commercial Failed 2/17/2023 2/17/2023 02/17/2023
Misc
Corrective Action Required
02/17/2023
UNIT A: -Vent all bath fans to outdoor -Protect 3” waste drain at kitchen/bath wall -Complete supply ducting above kitchen -Seal vent roof flashings -Fb duct penetration of wall plates -Install dryer duct -Protect AC line at closet UNIT B: -Vent all bath fans to outdoor -Nail hangers to I beam above half bathroom -Protect 3” waste drain at kitchen/bath wall -Complete supply duct to half bath -Complete installing dryer duct -Support vent in attic per code -Reinstall LIB brace strap at master closet UNIT C: -Vent all bath fans to outdoor -Slope plumbing above half bath per code -Complete supply duct to half bath -Complete installing dryer duct -Move b-vent min 1” from combustible material -Reinstall stud at laundry firewall -Install stud shoe at over bored laundry stud -Seal vent roof flashings -Support vent in attic per code -Protect wiring at rear bathroom bottom wall plate UNIT D: -Vent all bath fans to outdoor -Protect 3” waste drain at kitchen/bath wall -Complete supply ducting above kitchen -Seal vent roof flashings -Complete installing water valves to bathroom shower and tub -Install dryer duct -Protect AC line at closet **OK TO INSULATE
Gas Service Inspection - Commercial Passed 2/22/2023 2/22/2023 02/22/2023
Misc
Resolved
02/22/2023
-Unit A has no pressure
All Rough Inspection - Commercial Failed 2/22/2023 2/22/2023 02/22/2023
Misc
Corrective Action Required
02/17/2023
UNIT C: -Move b-vent min 1” from truss
All Rough Inspection - Commercial Failed 2/23/2023 2/23/2023 02/23/2023
Misc
Corrective Action Required
02/22/2023
UNIT C: -Move b-vent min 1” from truss **still not corrected
All Rough Inspection - Commercial Passed 2/28/2023 2/28/2023 02/28/2023
Misc
Resolved
02/28/2023
UNIT C: -Move b-vent min 1” from truss **still not corrected
Rated Assembly Inspection Partial 2/28/2023 2/28/2023 02/28/2023
Misc
Corrective Action Required
12/20/2022
Attic firewall-2nd layer ok Dwelling firewall-1st layer ok
Rated Assembly Inspection Passed 3/6/2023 3/6/2023 03/06/2023
Misc
Resolved
03/06/2023
Attic firewall-2nd layer ok Dwelling firewall-1st layer ok
Occupancy Inspection - Codes Commercial Failed 6/7/2023 6/7/2023 06/07/2023
Misc
Corrective Action Required
06/07/2023
EXTERIOR: -Downspout splash blocks -Seal exterior lights, wall penetrations, seal/flash above&behind service equipment, etc UNIT A: -Install kitchen island receptacle cover plate UNIT B: -Fix patio gfci receptacle keeps tripping UNIT C: -Install water heater P&T discharge pipe UNIT D-OK
Occupancy Inspection - Codes Commercial Ready for Temp CO 6/13/2023 6/13/2023 06/13/2023
Misc
Corrective Action Required
06/07/2023
EXTERIOR: -Downspout splash blocks -Seal exterior lights, wall penetrations, seal/flash above&behind service equipment, etc
Occupancy Inspection - Codes Commercial Full C of O 6/19/2023 06/19/2023
Misc
Resolved
06/19/2023
EXTERIOR: -Downspout splash blocks -Seal exterior lights, wall penetrations, seal/flash above&behind service equipment, etc
Documents & Images
Date Uploaded File Type Document Name
08/24/2022 Receipt Receipt for transaction:2022-006945
08/25/2022 Letter DS Building Permit
09/29/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
02/17/2023 Letter INSPECTION SUMMARY
02/17/2023 Letter INSPECTION SUMMARY
02/17/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
06/07/2023 Letter INSPECTION SUMMARY
06/13/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/13/2023 Receipt Receipt for transaction:2023-004317
06/19/2023 Letter Codes Final Certificate of Occupancy
06/19/2023 Letter Field Certificate of Occupancy
12/20/2023 Codes Temporary Certificate of Occupancy230
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home