Summary
PRCOM20193595
Building Permit - Commercial
Final Completion
ER PROPERTIES LLC
NEW OTHER (COMMERCIAL)
TEMPORARY ELECTRICAL SERVICE FOR STORAGE BUILDINGS
12/11/2019
12/11/2019
12/18/2019
Locations
Contacts
ER PROPERTIES LLC, Address:720 S ROGERS RD  
BOWERS ELECTRIC LLC, Address:720 S ROGERS RD, STE C200, Phone:(913) 530-8003  
GLENN@BOWERSELECTRIC.NET  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 12/11/2019 12/11/2019
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $30.00 $30.00 Paid 12/11/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Electrical Inspection - Commercial Failed 12/12/2019 at 11:45 AM 12/12/2019
Misc
Corrective Action Required
12/12/2019
-CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE GROUDED BUS BAR WHERE THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO (250.24) -BONDING CONNECTION REQUIRES MIN 2 THREADS OF METAL-METAL CONTACT OR REMOVE ENAMEL (250.118)
Electrical Service Inspection Passed 12/18/2019
Final Electrical Inspection - Commercial Passed 12/18/2019 at 9:05 AM 12/18/2019
Misc
Resolved
12/18/2019
-CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE GROUDED BUS BAR WHERE THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO (250.24) -BONDING CONNECTION REQUIRES MIN 2 THREADS OF METAL-METAL CONTACT OR REMOVE ENAMEL (250.118)
Documents & Images
Date Uploaded File Type Document Name
12/11/2019 Receipt Receipt for transaction: 2019-007693
12/11/2019 Letter DS Building Permit
12/12/2019 Letter INSPECTION SUMMARY
12/12/2019 Scope of Work DOC121219-12122019100001
12/18/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home