Summary
PRCOM20193021
Building Permit - Commercial
Final Completion
NEW OTHER (COMMERCIAL)
TEMPORARY SERVICE FOR NEW CONSTRUCTION
10/15/2019
10/15/2019
10/25/2019
Locations
Contacts
BLUE SPRINGS ELECTRICAL SERVICE, Address:3402 LAKE SHORE DR, Phone:(816) 224-9911  
JERRY@BLUESPRINGSELECTRIC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 10/15/2019 10/15/2019
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Other $30.00 $30.00 Paid 10/15/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 10/21/2019 10/21/2019 at 12:45 PM 10/21/2019
Misc
Corrective Action Required
10/21/2019
-PLUG OPENING AT BOTTOM OF DISCONNECT ENCLOSURE -INSTALL THE EQUIPMENT GROUNDING CONDUCTOR FOR THE FEEDER. WHERE DOES THE FEEDER GO TO? -250.24 REQUIRES THAT THE GROUNDING ELECTRODE CONDUCTOR (GEC) BE CONNECTED TO THE SERVICE GROUNDED CONDUCTOR, OR A JUMPER SAME SIZE AS THE GEC CONNECT THE GEC TO THE BUS BAR THAT THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO
Electrical Service Inspection Failed 10/21/2019 10/21/2019
Misc
Corrective Action Required
10/21/2019
-PLUG OPENING AT BOTTOM OF DISCONNECT ENCLOSURE -INSTALL THE EQUIPMENT GROUNDING CONDUCTOR FOR THE FEEDER. -GROUND THE SERVICE DISCONNECT ON THE LOAD SIDE OF THE TRANSFORMER -250.24 REQUIRES THAT THE GROUNDING ELECTRODE CONDUCTOR (GEC) BE CONNECTED TO THE SERVICE GROUNDED CONDUCTOR, OR A JUMPER SAME SIZE AS THE GEC CONNECT THE GEC TO THE BUS BAR THAT THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO
Electrical Service Inspection Passed 10/25/2019 at 9:50 AM 10/25/2019
Misc
Resolved
10/25/2019
Final Inspection - Commercial Passed 10/25/2019
Documents & Images
Date Uploaded File Type Document Name
10/15/2019 Receipt Receipt for transaction: 2019-006780
10/15/2019 Letter DS Building Permit
10/16/2019 Scope of Work DOC101619-013
10/21/2019 Letter INSPECTION SUMMARY
10/21/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home