PRCOM20180429


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20180429
Building Permit - Commercial
Voided
ALDERSGATE METHODIST CHURCH
NEW OTHER (COMMERCIAL)
STORAGE SHED 24 X 30
02/27/2018
08/27/2018
03/11/2019
Locations
Contacts
ALDERSGATE METHODIST CHURCH, Address:350 SW M 150 HWY  
QUALITY STRUCTURES INC, Address:167 HWY 59, Phone:(785) 835-6100  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Rejected 03/13/2018 02/28/2018
Joe Frogge
Final Development Plan
Corrective Action Required
02/28/2018

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes.
Project cost
Corrective Action Required
02/28/2018

The project cost, which is used to establish the permit fee, has not been provided. Action required: Comment is for informational purposes.
Misc
Corrective Action Required
02/28/2018

Inadequate information to complete review. Provide the following: - Describe intended use. - Provide information as to what will be stored. - Provide mechanical, electrical, and plumbing designs if applicable. - Specify minimum footing/pier depths.
Misc
Corrective Action Required
02/28/2018

2012 IBC 1803.1 General. Geotechnical investigations shall be conducted in accordance with Section 1803.2 and reported in accordance with Section 1803.6. Where required by the building official or where geotechnical investigations involve in-situ testing, laboratory testing or engineering calculations, such investigations shall be conducted by a registered design professional. Action required: Provide soils report to justify design assumption of soil bearing capacity greater than 2,000psf.
Gen - Submittal documents 7-137
Corrective Action Required
02/28/2018

Lee's Summit Code Of Ordinances 7-137. - Submittal Documents. Construction documents, special inspection and structural observation programs, and other data shall be submitted in two (2) or more sets with each application for a permit. A registered design professional licensed by the State of Missouri shall prepare the construction documents. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional licensed by the State of Missouri. Action required: Truss component drawing is 7 years old. Provide current design seal/signature.
Code analysis required
Corrective Action Required
02/28/2018

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide detailed code analysis. Include impacts of IBC Tables 503, 601, & 602 as concerns maximum heights/areas and fire resistance ratings.
Bldg - Landings at doors 1008.1.6
Corrective Action Required
02/28/2018

2012 IBC 1008.1.6 - Landings at doors. Landings shall have a width not less than the width of the stairway or the door, whichever is greater. Doors in the fully open position shall not reduce a required dimension by more than 7 inches. When a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing to less than one-half its required width. Landings shall have a length measured in the direction of travel of not less than 44 inches. Exception: Landing length in the direction of travel in Groups R-3 and U and within individual units of Group R-2 need not exceed 36 inches. Action required: Provide landing at man door.
Licensed Contractors Approved 03/13/2018 02/28/2018
Joe Frogge
Fire Plan Review Rejected 03/13/2018 02/28/2018
Joe Dir
Misc
Corrective Action Required
02/28/2018

location of bldg ACTION REQUIRED: Provide drawings indicating the location of the bldg on the lot and in correlation to church bldg.
Misc
Corrective Action Required
02/28/2018

bldg utilization ACTION REQUIRED: provide infomation as to what will be stored in the bldg, flammable liquids, corrosives, hazardous materials, ????
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
02/28/2018 Letter Fire Building Plan Review
02/28/2018 Letter Codes P/R Corrections Document
09/06/2018 Letter Application Expired Notice
09/11/2018 Re Aldersgate storage building
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home