Permit Application Status

PRCOM20172515


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20172515
Building Permit - Commercial
Certificate of Occupancy
PARROT PROPERTIES INC
NEW MULTI-FAMILY
BUILDING #7 NEW 2 STORY APARTMENT BUILDING WITH PARKING GARAGE BENEATH FOUNDATION PERMIT - PRCOM20181902
07/24/2017
01/07/2019
10/30/2020
Locations
Contacts
CITYSCAPE CONSTRUCTION VIEW HIGH LLC, Address:10 W CARMEL DR STE 200, Phone:(317) 574-1600 Ext:100  
STANDARD HEATING & COOLING TOO LLC, Address:2006 E PRAIRIE CIRCLE , Phone:(913) 782-5409  
STANDARD ELECTRIC TOO LLC, Address:2006 E PRAIRIE CIRCLE, Phone:(913) 782-5409  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
SGN+A ARCHITECTS, Address:315 W PONCE DE LEON AVE #755, Phone:(404) 373-7370  
LATIMER SOMMERS & ASSOCIATES PA, Address:3639 SW SUMMERFIELD DR STE A, Phone:(785) 233-3232  
PARROT PROPERTIES INC, Address:11303 VIEW HIGH DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 07/25/2018 06/19/2018
Joe Frogge
Final Development Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Building Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Special Inspections Review Approved 08/24/2017
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Multi-Family $6,467.04 $6,467.04 Paid 01/07/2019
8331507-Sewer Connection Fee $3,000.00 $3,000.00 Paid 01/07/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 12/06/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 3/8/2019 3/8/2019 at 8:00 AM 03/08/2019
Misc
Partial Correction
03/08/2019
REAR FACE BASEMENT WALL FOOTING (WEST ELEVATION) APPROVED TO POUR.
Footing Inspection - Commercial Partial 3/20/2019 3/20/2019 03/20/2019
Misc
Partial Correction
03/20/2019
EAST AND WEST ELEVATION APPROVED
Sewer Service Inspection Passed 4/4/2019 4/4/2019 04/04/2019
Misc
Informational
04/04/2019
Rick from Garrison Plumbing did a sanitary service line tie in. They used strong back Fernco clamps.
Underslab Plumbing Inspection - Commercial Passed 4/15/2019 4/15/2019 at 12:50 PM 04/15/2019
Footing Inspection - Commercial Partial 6/11/2019 6/11/2019 06/11/2019
Misc
Partial Correction
03/20/2019
EAST AND WEST ELEVATION APPROVED. upper west side Ufer in South side
Underslab Plumbing Inspection - Commercial Passed 6/18/2019 6/18/2019 06/18/2019
Rated Assembly Inspection Failed 10/1/2019 10/01/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
10/01/2019
OK TO SET TUBS ONLY
FIRST FLOOR
Corrective Action Required
10/01/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK.
SECOND FLOOR
Corrective Action Required
10/01/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK.
LOWER LEVEL
Corrective Action Required
10/01/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK.
All Rough Inspection - Commercial Failed 6/18/2019 10/1/2019 10/01/2019
Misc
Corrective Action Required
10/01/2019
2nd floor 302 Screws in,pre-rock hurricane tie 301-truss hangers back door , hurricane over porch. Tie on girter truss bedroom. Screw pattern on peer rock. Corridor north stairs hanger 2x4 ceiling joist to truss. 304- screws on pre rock. 303-ok 306-plumbing nail guard bottom plate bedroom closet. Seal gap in pre-rock 305-puddly pad kitchen wall. Seal gaps on pre-rock. Hurricane tie on bedroom truss girter. Corridor north ceiling joist hangers . Terminate exit light in box over north stairs. Pre-rock hallway north end screw pattern. 308-pre rock gaps , screw pattern. Truss hangers. 307-truss hangers , ties on girter truss bedroom. Pre-rock ok 1st floor- 207-electrical to porch outlet box deck not installed. Gap in pre-rock 208-pre rock ok Corridor hvac north end pre rock. 205- prerock 206-ok 203- 204- 202- south wall at ac line set install stud for cut in plates. Terminate elect over south stairs 1st floor. Support DWV north garage #2
All Rough Inspection - Commercial Failed 10/4/2019 10/4/2019 10/04/2019
Misc
Corrective Action Required
10/01/2019
Support DWV north garage #2 support dwv in all garages.
Rated Assembly Inspection Failed 10/4/2019 10/04/2019
Misc
Corrective Action Required
10/04/2019
Check all pre-rock areas , gaps in ceiling and screw pattern. ok to insulate and install RC
Rated Assembly Inspection Failed 10/25/2019 10/25/2019
LOWER LEVEL
Corrective Action Required
10/04/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC - EXCEPT MECHANICAL ROOM AND 2ND GARAGE TO THE NORTH
SECOND FLOOR
Corrective Action Required
10/04/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
FIRST FLOOR
Corrective Action Required
10/04/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
10/04/2019
OK TO SET TUBS ONLY
Misc
Corrective Action Required
10/25/2019
PRE-ROCK AERAS STILL INCOMPLETE DO NOT COVER.
Rated Assembly Inspection Not Ready 11/5/2019 11/5/2019 11/05/2019
LOWER LEVEL
Corrective Action Required
10/25/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC - EXCEPT MECHANICAL ROOM AND 2ND GARAGE TO THE NORTH
SECOND FLOOR
Corrective Action Required
10/25/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
FIRST FLOOR
Corrective Action Required
10/25/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
10/25/2019
OK TO SET TUBS ONLY
Misc
Corrective Action Required
10/25/2019
PRE-ROCK AERAS STILL INCOMPLETE DO NOT COVER. Same as the last 3 inspections - re-inspection fee added.
All Rough Inspection - Commercial Passed 11/8/2019 11/08/2019
Misc
Resolved
11/08/2019
Support DWV north garage #2 support dwv in all garages.
Rated Assembly Inspection Partial 11/8/2019 11/08/2019
LOWER LEVEL
Corrective Action Required
11/05/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC - EXCEPT MECHANICAL ROOM AND 2ND GARAGE TO THE NORTH
SECOND FLOOR
Corrective Action Required
11/05/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
FIRST FLOOR
Corrective Action Required
11/05/2019
PRE-ROCK FAILED, SCREW PATTERN, GAPS, FIRE CAULK. RC OK
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
11/05/2019
OK TO SET TUBS ONLY PRE-ROCK OK
Misc
Resolved
11/08/2019
PRE-ROCK AERAS STILL INCOMPLETE DO NOT COVER. Same as the last 3 inspections - re-inspection fee added.
Rated Assembly Inspection Partial 12/4/2019 12/4/2019 12/05/2019
LOWER LEVEL
Corrective Action Required
11/08/2019
ok
SECOND FLOOR
Corrective Action Required
11/08/2019
RC OK Screw pattern needs corrected and holes in ceiling in units repair corridor wall gaps.
FIRST FLOOR
Corrective Action Required
11/08/2019
RC OK units okrepair corridor wall gaps.
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
11/08/2019
OK TO SET TUBS ONLY PRE-ROCK OK Units ok to cover-
Rated Assembly Inspection Passed 12/5/2019 12/05/2019
LOWER LEVEL
Informational
12/05/2019
ok
SECOND FLOOR
Informational
12/05/2019
RC OK units ok
FIRST FLOOR
Informational
12/05/2019
RC OK unit ok
THE FOLLOWING AREAS ARE APPROVED
Informational
12/05/2019
OK TO SET TUBS ONLY PRE-ROCK OK Units ok to cover-
Electrical Service Inspection Passed 1/8/2020 1/8/2020 01/08/2020
Sprinkler - Hydrostatic Test Passed 4/1/2020 04/01/2020
Piers/Caissons Inspection - Commercial Partial 4/17/2020 4/17/2020 04/17/2020
Misc
Informational
04/17/2020
- 1 LIGHT POLE BASE, DRIVEN GROUND ROD IN PLACE SOUTH END OF BLDG -
Sprinkler - Flow Test Passed 4/23/2020 04/23/2020
Alarm Test Passed 4/23/2020 04/23/2020
Water Service Inspection Passed 4/27/2020 04/27/2020
Occupancy Inspection - Fire Failed 4/29/2020 04/29/2020
Occupancy Inspection - Codes Commercial Failed 4/29/2020 4/29/2020 04/29/2020
Misc
Corrective Action Required
04/29/2020
- INSTALL GARAGE DOOR OPENERS, DOORS BUTTONS, SENSORS & FIRE CAULK - -NORTH BASEMENT HALL EXIT SIGN NOT INSTALLED - - NORTH EXIT POUR LANDING, OPEN BOX CEILING, SOFFIT NOT INSTALLED - - SOUTH BASEMENT FIRE ALARM PANEL ROOM HOLE IN CEILING, FIRE CAULK CEILING PENETRATIONS, - - FIRE CAULK STAND PIPES - - 207 HOLE IN CEILING LAUNDRY, DECK RAILING SHALL NOT ALLOW 4" SPHERE TO PASS THROUGH - - 205 GFCI RIGHT OF KITCHEN SINK DEAD - - G7-2 FLUSH MOUNT CLEAN OUT - - PROVIDE TAMPER PROOF CAPS A/C CONDENSORS - -
Miscellaneous Inspection Passed 4/30/2020 4/30/2020 04/30/2020
Misc
Informational
04/30/2020
- UNIT 207 LAUNDRY & FIRE ALARM ROOM CEILING PATCHES OK TO TAPE -
Occupancy Inspection - Planning Temporary C of O 05/08/2020
Occupancy Inspection - Fire Passed 5/8/2020 5/8/2020 05/08/2020
Footing Inspection - Commercial Passed 5/8/2020 05/08/2020
Misc
Partial Correction
06/11/2019
EAST AND WEST ELEVATION APPROVED. upper west side Ufer in South side
Piers/Caissons Inspection - Commercial Passed 5/8/2020 05/08/2020
Rough Electrical Inspection - Commercial Passed 5/8/2020 05/08/2020
Rough Mechanical Inspection - Commercial Passed 5/8/2020 05/08/2020
Rough Plumbing Inspection - Commercial Passed 5/8/2020 05/08/2020
Final Plumbing Inspection - Commercial Passed 5/8/2020 05/08/2020
Final Mechanical Inspection Passed 5/8/2020 05/08/2020
Final Electrical Inspection - Commercial Passed 5/8/2020 05/08/2020
Occupancy Inspection - Codes Commercial Temporary C of O 5/8/2020 5/8/2020 05/08/2020
Misc
Resolved
05/08/2020
OK FOR TCO WHEN FIRE PASSES INSPECTION
Occupancy Inspection - Engineering Passed 10/30/2020
Occupancy Inspection - Water Utilities Passed 10/30/2020
Occupancy Inspection - Codes Commercial Full C of O 10/30/2020
Documents & Images
Date Uploaded File Type Document Name
10/16/2017 Meridian Site Map
01/07/2019 Letter Codes Building Permit
01/07/2019 Receipt Receipt for transaction: 2019-000072
03/08/2019 Letter INSPECTION SUMMARY
03/20/2019 Letter INSPECTION SUMMARY
04/04/2019 Letter INSPECTION SUMMARY
04/15/2019 Letter INSPECTION SUMMARY
06/11/2019 Letter INSPECTION SUMMARY
06/18/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
11/05/2019 Letter INSPECTION SUMMARY
11/08/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
01/08/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
04/30/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter Codes Temporary Certificate of Occupancy
10/30/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home