Summary
PRCOM20172509
Building Permit - Commercial
Certificate of Occupancy
PARROT PROPERTIES INC
NEW MULTI-FAMILY
BUILDING #4 NEW APARTMENT WITH PARKING GARAGE BENEATH FOUNATION PERMIT - PRCOM20180700
07/24/2017
01/07/2019
11/08/2019
Locations
Contacts
CITYSCAPE CONSTRUCTION VIEW HIGH LLC, Address:10 W CARMEL DR STE 200, Phone:(317) 574-1600 Ext:100  
PARROT PROPERTIES INC, Address:11303 VIEW HIGH DR  
STANDARD HEATING & COOLING TOO LLC, Address:2006 E PRAIRIE CIRCLE , Phone:(913) 782-5409  
STANDARD ELECTRIC TOO LLC, Address:2006 E PRAIRIE CIRCLE, Phone:(913) 782-5409  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
LATIMER SOMMERS & ASSOCIATES PA, Address:3639 SW SUMMERFIELD DR STE A, Phone:(785) 233-3232  
SGN+A ARCHITECTS, Address:315 W PONCE DE LEON AVE #755, Phone:(404) 373-7370  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 07/25/2018 06/19/2018
Joe Frogge
Building Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Final Development Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Special Inspections Review Approved 08/24/2017
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Multi-Family $8,130.68 $8,130.68 Paid 01/07/2019
8331507-Sewer Connection Fee $3,000.00 $3,000.00 Paid 01/07/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection Passed 1/14/2019 1/14/2019 01/14/2019
Sprinkler - Hydrostatic Test Passed 4/24/2019 04/24/2019
All Rough Inspection - Commercial Partial 5/8/2019 5/8/2019 05/08/2019
FIRST FLOOR
Informational
05/08/2019
ALL-ROUGH
SECOND FLOOR
Corrective Action Required
05/08/2019
allrough
LOWER LEVEL
Corrective Action Required
05/08/2019
pending box outs for DWV in garages
Rated Assembly Inspection Partial 5/8/2019 5/8/2019 05/16/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/08/2019
pre rock-tub showers dryer boxes furnace rooms.
LOWER LEVEL
Corrective Action Required
05/08/2019
FIRST FLOOR
Corrective Action Required
05/08/2019
SECOND FLOOR
Corrective Action Required
05/08/2019
Rated Assembly Inspection Partial 5/16/2019 05/16/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/16/2019
pre rock-tub showers dryer boxes furnace rooms.
LOWER LEVEL
Corrective Action Required
05/16/2019
FIRST FLOOR
Corrective Action Required
05/16/2019
RC
SECOND FLOOR
Corrective Action Required
05/16/2019
RCEXCEPT RM 305 AND HALL OUTSIDE 305
Rated Assembly Inspection Partial 5/17/2019 5/17/2019 05/17/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/16/2019
pre rock-tub showers dryer boxes furnace rooms. HAT CHANNEL LIDS TOP FLOOR APPROVED
LOWER LEVEL
Corrective Action Required
05/16/2019
FIRST FLOOR
Corrective Action Required
05/16/2019
RC
SECOND FLOOR
Corrective Action Required
05/16/2019
RC-EXCEPT RM 305 AND HALL OUTSIDE 305
Rated Assembly Inspection Partial 5/20/2019 5/20/2019 at 11:00 AM 05/20/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/17/2019
pre rock-tub showers dryer boxes furnace rooms. HAT CHANNEL LIDS TOP FLOOR APPROVED
LOWER LEVEL
Corrective Action Required
05/17/2019
Hat channel lower level approved
FIRST FLOOR
Corrective Action Required
05/17/2019
RC
SECOND FLOOR
Corrective Action Required
05/17/2019
RC-EXCEPT RM 305 AND HALL OUTSIDE 305
Rated Assembly Inspection Partial 5/22/2019 5/22/2019 at 10:00 AM 05/22/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/20/2019
pre rock-tub showers dryer boxes furnace rooms. HAT CHANNEL LIDS TOP FLOOR APPROVED
LOWER LEVEL
Corrective Action Required
05/20/2019
Hat channel lower level approved
FIRST FLOOR
Corrective Action Required
05/20/2019
rc LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Rated Assembly Inspection Partial 5/24/2019 5/24/2019 at 9:45 AM 05/24/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/22/2019
pre rock-tub showers dryer boxes furnace rooms. HAT CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED
LOWER LEVEL
Corrective Action Required
05/22/2019
Hat channel lower level approved
FIRST FLOOR
Corrective Action Required
05/22/2019
rc LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Rated Assembly Inspection Failed 5/28/2019 5/28/2019 05/28/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/24/2019
pre rock-tub showers dryer boxes furnace rooms. HAT CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED
LOWER LEVEL
Corrective Action Required
05/24/2019
RC channel lower level approved
FIRST FLOOR
Corrective Action Required
05/24/2019
rc LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Misc
Corrective Action Required
05/28/2019
SCREW PATTERN MISSING ROCK AT ISLAND WALLS KITCHEN WHERE MEETS PARTY WALL.
Rated Assembly Inspection Partial 5/30/2019 5/30/2019 05/30/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/28/2019
pre rock-tub showers dryer boxes furnace rooms. RC CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED
LOWER LEVEL
Corrective Action Required
05/28/2019
RC channel lower level approved
FIRST FLOOR
Corrective Action Required
05/28/2019
RC LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Misc
Corrective Action Required
05/28/2019
CORRIDOR AND SOUTH GARAGE NEEDS ALL CEILING PENETRATIONS SEALED FOR FLOOR CEILING ASSEMBLY AREAS UNDER DECKS NEED INSPECTED WHEN READY LOWER GARAGE AREAS (4)
Rated Assembly Inspection Partial 6/4/2019 6/4/2019 06/04/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/30/2019
pre rock-tub showers dryer boxes furnace rooms. RC CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED -SOUTH STAIR TOWER
LOWER LEVEL
Corrective Action Required
05/30/2019
RC channel lower level approved
FIRST FLOOR
Corrective Action Required
05/30/2019
RC LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Misc
Corrective Action Required
05/30/2019
CORRIDOR AND SOUTH GARAGE NEEDS ALL CEILING PENETRATIONS SEALED FOR FLOOR CEILING ASSEMBLY AREAS UNDER DECKS NEED INSPECTED WHEN READY LOWER GARAGE AREAS (4)
SECOND FLOOR
Corrective Action Required
06/04/2019
OK UNITS
Rated Assembly Inspection Partial 6/12/2019 6/12/2019 06/12/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
06/04/2019
pre rock-tub showers dryer boxes furnace rooms. RC CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED -SOUTH STAIR TOWER
LOWER LEVEL
Corrective Action Required
06/04/2019
RC channel lower level approved
FIRST FLOOR
Corrective Action Required
06/04/2019
RC LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Misc
Corrective Action Required
06/04/2019
CORRIDOR AND SOUTH GARAGE NEEDS ALL CEILING PENETRATIONS SEALED FOR FLOOR CEILING ASSEMBLY remaining:lower Corridors , stair towers , electrical drops in garages.
SECOND FLOOR
Corrective Action Required
06/04/2019
OK UNITS
Rated Assembly Inspection Partial 6/19/2019 6/19/2019 06/19/2019
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
06/12/2019
pre rock-tub showers dryer boxes furnace rooms. RC CHANNEL LIDS TOP FLOOR APPROVED -TOP FLOOR UNITS APPROVED -STAIR TOWERS
LOWER LEVEL
Corrective Action Required
06/12/2019
RC channel lower level approved
FIRST FLOOR
Corrective Action Required
06/12/2019
RC LAUNDRY BOXES, TUBS AND SHOWERS APPROVED PRE ROCK
Misc
Corrective Action Required
06/12/2019
CORRIDOR AND SOUTH GARAGE NEEDS ALL CEILING PENETRATIONS SEALED FOR FLOOR CEILING ASSEMBLY remaining:lower Corridors , electrical drops in garages.
SECOND FLOOR
Corrective Action Required
06/12/2019
OK UNITS
Electrical Service Inspection Passed 7/8/2019 7/8/2019 07/08/2019
Above Ceiling Inspection Passed 7/11/2019 7/11/2019 07/11/2019
Alarm Test Passed 10/23/2019
Sprinkler - Flow Test Passed 10/23/2019
Occupancy Inspection - Planning Temporary C of O 11/01/2019
Corrective Action Required
11/01/2019
Sod shall be installed.
Corrective Action Required
11/01/2019
General site cleanup is needed for the parking areas.
Occupancy Inspection - Fire Passed 11/1/2019 11/01/2019
Occupancy Inspection - Codes Commercial Failed 11/1/2019 11/1/2019 at 9:30 AM 11/01/2019
Occupancy Inspection - Codes Commercial Failed 11/1/2019 at 3:10 PM 11/01/2019
Misc
Corrective Action Required
11/01/2019
COMPLETE ALL WORK AT RISER ROOM INCLUDING FIRESTOPPING OF RATED ASSEMBLIES
Misc
Corrective Action Required
11/01/2019
IT ROOM: - PLUG UNUSED OPENING AT PANEL POSITION #41 - OPENING ABOVE DOOR IN RATED WEST WALL?
Misc
Corrective Action Required
11/01/2019
BALCONY GUARD POST BASES: CHECK ALL FOR MISSING OR LOOSE SCREWS
Misc
Corrective Action Required
11/01/2019
NEC 314-20; IRC E3906.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. CHECK ALL AT KITCHEN BACKSPLASH.
Misc
Corrective Action Required
11/01/2019
SOME ELECT RECEPTS NOT SOLID TO BOX -- MARKED WITH TAPE
Occupancy Inspection - Codes Commercial Full C of O 11/8/2019 11/8/2019 11/08/2019
Misc
Resolved
11/08/2019
COMPLETE ALL WORK AT RISER ROOM INCLUDING FIRESTOPPING OF RATED ASSEMBLIES -IT ROOM: - PLUG UNUSED OPENING AT PANEL POSITION #41 - OPENING ABOVE DOOR IN RATED WEST WALL? -BALCONY GUARD POST BASES: CHECK ALL FOR MISSING OR LOOSE SCREWS -NEC 314-20; IRC E3906.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. CHECK ALL AT KITCHEN BACKSPLASH. -SOME ELECT RECEPTS NOT SOLID TO BOX -- MARKED WITH TAPE
Documents & Images
Date Uploaded File Type Document Name
10/16/2017 Meridian Site Map
01/07/2019 Letter Codes Building Permit
01/07/2019 Receipt Receipt for transaction: 2019-000072
01/14/2019 A34D81B9-88F7-4637-89BC-82D3C3626E65
01/14/2019 E9BE1851-3F6D-4EC7-8A39-C8DCBE78440A
01/14/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/17/2019 Letter INSPECTION SUMMARY
05/22/2019 Letter INSPECTION SUMMARY
05/24/2019 Letter INSPECTION SUMMARY
05/28/2019 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/12/2019 Letter INSPECTION SUMMARY
06/19/2019 Letter INSPECTION SUMMARY
07/08/2019 Letter INSPECTION SUMMARY
07/11/2019 Letter INSPECTION SUMMARY
11/01/2019 Letter INSPECTION SUMMARY
11/08/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home