Summary
PRCOM20170850
Building Permit - Commercial
Certificate of Occupancy
DACUR INVESTMENT COMPANY INC
NEW TENANT FINISH
TENANT FINISH FOR HAIR AND NAIL SALON
03/24/2017
05/12/2017
10/07/2017
03/10/2018
Locations
Contacts
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
LYNN BARROW, Address:9000 E 327TH, Phone:(816) 835-2109  
B & C MECHANICAL SERVICES LLC, Address:2008 E SPRUCE CIR STE B, Phone:(913) 681-0088  
SINEWAVE ELECTRIC, Address:19013 E RINGO CIR, Phone:(816) 255-5264  
ROBERT RUHL, Address:21207 SCHOOL RD , Phone:(816) 365-8746  
SCHARHAG ARCHITECTS, Address:310 ARMOR RD, #22, Phone:(816) 221-9297  
GRADIENT COMPANY , Address:8205 LEGLER RD, Phone:(913) 787-0069  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 04/27/2017 04/24/2017
Joe Frogge
License Tax Application
Corrective Action Required
04/20/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 4/10/17 - acknowledged
Bldg - Door swing 1008.1.2
Resolved
04/24/2017

2012 IBC 1008.1.2 – Door swing. Egress doors shall be of the pivoted or side-hinged swinging type. Exceptions: (See code for possible exceptions.) Doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. Action required: Increased size of break room requires that doors be side-hinged swinging type. (See item #9 in exceptions)
r
Licensed Contractors Rejected 04/20/2017 04/24/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
04/20/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
04/20/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
a
Fire Plan Review Approved with Conditions 04/27/2017 04/21/2017
Joe Dir
Portable fire extinguishers - general
Corrective Action Required
04/20/2017

2012IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide a minimum of one 2A-10BC (5 pound) fire extinguisher. to be mounted on a normal path of travel clos to an exit.
Address numbers required
Corrective Action Required
04/20/2017

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Post the numeric address of 236 on the exterior of the front and back doors in a contrasting color to the background where posted. The address shall be readable from the roadway.
Misc
Corrective Action Required
04/20/2017

ACTION REQUIRED: (verified at inspection) NO KEYED LOCKS ON THE EGRESS SIDE OF THE FRONT AND BACK DOORS. [B] 1008.1.9 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. [B] 1008.1.9.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1. On doors not required for egress in individual dwelling units or sleeping units. 2. Where a pair of doors serves a storage or equipment room, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 4. Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf provided such inactive leaf is not needed to meet egress width requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 5. Where a pair of doors serves patient care rooms in Group I-2 occupancies, self-latching edge- or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress width requirements and the inactive leaf contains no doorknobs, panic bars or similar operating hardware. [B] 1008.1.9.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. [B] 1008.1.9.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate.
Building Plan Review Rejected 04/13/2017 04/10/2017
Joe Frogge
License Tax Application
Corrective Action Required
04/06/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 4/10/17 - acknowledged
Gen - Submittal documents 7-137
Resolved
04/10/2017

Lee's Summit Code Of Ordinances 7-137. - Submittal Documents. Construction documents, special inspection and structural observation programs, and other data shall be submitted in two (2) or more sets with each application for a permit. A registered design professional licensed by the State of Missouri shall prepare the construction documents. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional licensed by the State of Missouri. Action required: Update code analysis to show actual occupant load. (we calculate 33)
Plumb - Minimum number of fixtures 403.1
Resolved
04/10/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Miscellaneous Correction
Resolved
04/10/2017

2012 IPC 403.2 Separate Facilities. (As amended by Lee’s Summit Code of Ordinances Section 7-405) Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate facilities shall not be required for dwelling units and sleeping units. 2. Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 25 or fewer. 3. Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or fewer. Action required: Provide additional restroom.
Miscellaneous Correction
Resolved
04/10/2017

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles within 6' of a sink will by GFCI protected. (ref: recept. near break room sink)
Misc 12
Resolved
04/10/2017

2012 IMC 403.3 Outdoor airflow rate. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with this section. The occupant load utilized for design of the ventilation system shall not be less than the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be those for a listed occupancy classification that is most similar in terms of occupant density, activities and building construction; or shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code. (see code section for smoking requirements and exception) Table 403.3 Footnote h. For nail salons, each nail station shall be provided with a source capture system capable of exhausting not less than 50 cfm. Action required: Modify mechanical design to provide source capture system at pedicure and manicure stations. Reference attached cut from IMC commentary.
Misc 13
Resolved
04/10/2017

2012 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Specify/detail accessible components of restroom. i.e. mirror, grab bars, dispensers, etc.
Misc 14
Resolved
04/10/2017

2012 IBC 1008.1.9.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 shall not require tight grasping, tight pinching or twisting of the wrist to operate. Action required: Provide additional information to verify that sliding barn door is compliant.
Bldg - Door swing 1008.1.2
Corrective Action Required
04/10/2017

2012 IBC 1008.1.2 – Door swing. Egress doors shall be of the pivoted or side-hinged swinging type. Exceptions: (See code for possible exceptions.) Doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. Action required: Increased size of break room requires that doors be side-hinged swinging type. (See item #9 in exceptions)
r
Licensed Contractors Rejected 04/06/2017 04/10/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
04/06/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
04/06/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 04/13/2017 04/07/2017
Joe Dir
Portable fire extinguishers - general
Corrective Action Required
04/06/2017

2012IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide a minimum of one 2A-10BC (5 pound) fire extinguisher. to be mounted on a normal path of travel clos to an exit.
Address numbers required
Corrective Action Required
04/06/2017

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Post the numeric address of 236 on the exterior of the front and back doors in a contrasting color to the background where posted. The address shall be readable from the roadway.
Misc
Corrective Action Required
04/06/2017

ACTION REQUIRED: (verified at inspection) NO KEYED LOCKS ON THE EGRESS SIDE OF THE FRONT AND BACK DOORS. [B] 1008.1.9 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. [B] 1008.1.9.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1. On doors not required for egress in individual dwelling units or sleeping units. 2. Where a pair of doors serves a storage or equipment room, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 4. Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf provided such inactive leaf is not needed to meet egress width requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 5. Where a pair of doors serves patient care rooms in Group I-2 occupancies, self-latching edge- or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress width requirements and the inactive leaf contains no doorknobs, panic bars or similar operating hardware. [B] 1008.1.9.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. [B] 1008.1.9.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate.
Building Plan Review Rejected 04/05/2017 03/30/2017
Joe Frogge
License Tax Application
Corrective Action Required
03/30/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Gen - Submittal documents 7-137
Corrective Action Required
03/30/2017

Lee's Summit Code Of Ordinances 7-137. - Submittal Documents. Construction documents, special inspection and structural observation programs, and other data shall be submitted in two (2) or more sets with each application for a permit. A registered design professional licensed by the State of Missouri shall prepare the construction documents. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional licensed by the State of Missouri. Action required: Update code analysis to show actual occupant load. (we calculate 33)
Plumb - Minimum number of fixtures 403.1
Corrective Action Required
03/30/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Miscellaneous Correction
Corrective Action Required
03/30/2017

2012 IPC 403.2 Separate Facilities. (As amended by Lee’s Summit Code of Ordinances Section 7-405) Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate facilities shall not be required for dwelling units and sleeping units. 2. Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 25 or fewer. 3. Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or fewer. Action required: Provide additional restroom.
Miscellaneous Correction
Corrective Action Required
03/30/2017

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles within 6' of a sink will by GFCI protected. (ref: recept. near break room sink)
Misc 12
Corrective Action Required
03/30/2017

2012 IMC 403.3 Outdoor airflow rate. Ventilation systems shall be designed to have the capacity to supply the minimum outdoor airflow rate determined in accordance with this section. The occupant load utilized for design of the ventilation system shall not be less than the number determined from the estimated maximum occupant load rate indicated in Table 403.3. Ventilation rates for occupancies not represented in Table 403.3 shall be those for a listed occupancy classification that is most similar in terms of occupant density, activities and building construction; or shall be determined by an approved engineering analysis. The ventilation system shall be designed to supply the required rate of ventilation air continuously during the period the building is occupied, except as otherwise stated in other provisions of the code. (see code section for smoking requirements and exception) Table 403.3 Footnote h. For nail salons, each nail station shall be provided with a source capture system capable of exhausting not less than 50 cfm. Action required: Modify mechanical design to provide source capture system at pedicure and manicure stations. Reference attached cut from IMC commentary.
Misc 13
Corrective Action Required
03/30/2017

2012 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Specify/detail accessible components of restroom. i.e. mirror, grab bars, dispensers, etc.
Misc 14
Corrective Action Required
03/30/2017

2012 IBC 1008.1.9.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 shall not require tight grasping, tight pinching or twisting of the wrist to operate. Action required: Provide additional information to verify that sliding barn door is compliant.
Licensed Contractors Rejected 03/27/2017 03/30/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
03/30/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
03/30/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 04/05/2017 03/29/2017
Joe Dir
Portable fire extinguishers - general
Corrective Action Required
03/29/2017

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: Provide a minimum of one 2A-10BC (5 pound) fire extinguisher. to be mounted on a normal path of travel clos to an exit. (verifed at inspection)
Address numbers required
Corrective Action Required
03/29/2017

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: Post the numeric address of 236 on the exterior of the front and back doors in a contrasting color to the background where posted. The address shall be readable from the roadway. (verified at inspection)
Misc
Corrective Action Required
03/29/2017

ACTION REQUIRED: NO KEYED LOCKS ON THE EGRESS SIDE OF THE FRONT AND BACK DOORS. [B] 1008.1.9 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. [B] 1008.1.9.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1. On doors not required for egress in individual dwelling units or sleeping units. 2. Where a pair of doors serves a storage or equipment room, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 4. Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf provided such inactive leaf is not needed to meet egress width requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall contain no doorknobs, panic bars or similar operating hardware. 5. Where a pair of doors serves patient care rooms in Group I-2 occupancies, self-latching edge- or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress width requirements and the inactive leaf contains no doorknobs, panic bars or similar operating hardware. [B] 1008.1.9.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. [B] 1008.1.9.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (information purposes)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $228.59 $228.59 Paid 05/10/2017
8331507-Sewer Connection Fee $420.00 $420.00 Paid 05/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Not Ready 5/18/2017 5/18/2017 05/18/2017
Underslab Plumbing Inspection - Commercial Not Ready 5/19/2017 5/19/2017 05/19/2017
Underslab Plumbing Inspection - Commercial Passed 5/22/2017 5/22/2017 05/22/2017
In-wall Inspection Not Ready 5/30/2017 05/30/2017
Misc
Corrective Action Required
05/30/2017
COMPLETE IN-WALL PLUMBING AND INSTALL SHIELD IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
05/30/2017
COMPLETE IN-WALL EXHAUST AIR DUCTWORK
Misc
Corrective Action Required
05/30/2017
NEC 250.148; IRC 3808.13 CONTINUITY OF BRANCH WIRING EQUIPMENT GROUNDING CONDUCTORS: WHEREVER >= 2 CABLES IN BOXES USE LISTED WIRE NUTS OR CRIMP CONNECTORS TO CREATE CONTINUITY. TWISTING ONLY OF GROUND CONDUCTORS IS NOT COMPLIANT CONNECTION.
In-wall Inspection Passed 6/1/2017 6/1/2017 06/01/2017
Misc
Resolved
06/01/2017
COMPLETE IN-WALL PLUMBING AND INSTALL SHIELD IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS (USE "BOCA" PLATES). CHECK ALL.
Misc
Resolved
06/01/2017
COMPLETE IN-WALL EXHAUST AIR DUCTWORK
Misc
Resolved
06/01/2017
NEC 250.148; IRC 3808.13 CONTINUITY OF BRANCH WIRING EQUIPMENT GROUNDING CONDUCTORS: WHEREVER >= 2 CABLES IN BOXES USE LISTED WIRE NUTS OR CRIMP CONNECTORS TO CREATE CONTINUITY. TWISTING ONLY OF GROUND CONDUCTORS IS NOT COMPLIANT CONNECTION.
Electrical Service Inspection Passed 6/19/2017 6/19/2017 06/19/2017
Above Ceiling Inspection Not Ready 6/19/2017 6/19/2017 06/19/2017
Misc
Corrective Action Required
06/19/2017
COMPLETE ACT CEILING GRID AND ALL SYSTEMS ABOVE GRID; THEN CALL TO REQUEST ABOVE-CEILING INSPECTION.
Above Ceiling Inspection Passed 6/20/2017 6/20/2017 06/20/2017
Misc
Resolved
06/20/2017
COMPLETE ACT CEILING GRID AND ALL SYSTEMS ABOVE GRID; THEN CALL TO REQUEST ABOVE-CEILING INSPECTION.
Miscellaneous Inspection Passed 5/23/2017 6/26/2017 06/26/2017
Occupancy Inspection - Codes Commercial Temporary C of O 6/27/2017 6/27/2017 06/27/2017
Occupancy Inspection - Fire Passed 6/27/2017 06/27/2017
Occupancy Inspection - Water Utilities Passed 06/28/2017
Occupancy Inspection - Codes Commercial Full C of O 03/10/2018
Documents & Images
Date Uploaded File Type Document Name
03/29/2017 Letter Fire Building Plan Review
03/30/2017 Letter Codes P/R Corrections Document
04/07/2017 Letter Fire Building Plan Review
04/10/2017 Letter Codes P/R Corrections Document
04/21/2017 Letter Fire Building Plan Review
05/10/2017 Receipt Receipt for transaction: 2017-002078
05/12/2017 Letter Codes Plan Review Conditions
05/12/2017 Letter Codes Building Permit
05/22/2017 Letter Inspection Summary
05/30/2017 Letter Inspection Summary
06/01/2017 Letter Inspection Summary
06/16/2017 Code Mod Request DOC061617
06/19/2017 Letter Inspection Summary
06/20/2017 Letter Inspection Summary
06/27/2017 Letter Codes Temporary Certificate of Occupancy
07/06/2017 Letter DOC070617-025
03/10/2018 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home