Permit Application Status

PRCOM20170518


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20170518
Building Permit - Commercial
Certificate of Occupancy
ARNETT DAVID BRIAN
CHANGE OF TENANT
TENANT FINISH FOR WINDOW TINTING SERVICE
02/27/2017
05/09/2017
10/24/2017
08/10/2017
Locations
Contacts
JR VENTURES INC, Address:9205 REDBUD LANE, Phone:(913) 208-3178  
N.P. HEATING AND COOLING INC, Address:6511 LEAVENWORTH RD, Phone:(913) 963-7194  
ELECTRIC SERVICE SPECIALIST , INC., Address:14612 W 71ST TERRACE, Phone:(913) 909-3858  
METRO PLUMBING, Address:2400 S 34TH ST, Phone:(816) 985-1020  
RBA ARCHITECTS, Address:22620 W 75TH STREET, Phone:(913) 221-5040  
ARNETT DAVID BRIAN, Address:7755 SHAWNEE MISSION PKWY  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 04/24/2017 05/09/2017
Development Center
LC - General Contractor
Resolved
05/09/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor. 4/19/17 - acknowledged in letter
LC - MEP Subs
Resolved
05/09/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 4/19/17 - acknowledged in letter
Building Plan Review Approved 05/01/2017 05/01/2017
Development Center
License Tax Application
Resolved
05/01/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 4/19/17 - acknowledged in letter
Code analysis required
Resolved
04/27/2017

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis. 4/19/17 - Provided. Make the following corrections: 1) This building is Type VB 2) Occupant load is 42
Bldg - Toilet room wall finish 1210.2.2
Resolved
04/27/2017

2012 IBC 1210.2.2 – Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finishes at restrooms and mop sink. (if paint is used, it must be epoxy based) 4/19/17 - Specify compliant wall finish at mop sink.
Misc
Resolved
04/27/2017

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles in service bays will by GFCI protected. 4/19/17 - Design provided, but not all relevant receptacles are protected.
Screening - Rooftop equipment
Resolved
04/27/2017

Unified Development Ordinance Article 7, Section 7.180.E Roof mounted equipment – All roof-mounted equipment shall be screened entirely from view by using parapet walls at the same height as the mechanical units. For additions to existing buildings that do not meet this standard, individual screens will be permitted, with the design subject to approval by the Director. Action required: Make needed corrections to drawings that provide details as to how roof mounted condensing units will be screened per referenced UDO section. 4/27/17 - units moved to ground
Misc
Resolved
04/27/2017

2012 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide verification that existing roof structure will support additional load imposed by condensing units. 4/27/17 - units moved to ground
Misc
Resolved
04/27/2017

2012 IPC 901.2 Trap seal protection. The plumbing system shall be provided with a system of vent piping that will permit the admission or emission of air so that the seal of any fixture trap shall not be subjected to a pneumatic pressure differential of more than 1 inch of water column. 901.2.1 Venting required. Traps and trapped fixtures shall be vented in accordance with one of the venting methods specified in this chapter. (see code for allowed methods) Action required: Provide vent at new water closet.
Misc
Resolved
04/27/2017

2011 NEC 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide receptacle near roof mounted condensing units.
Misc
Resolved
04/27/2017

2012 IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 2012 IBC 1006.3 – Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply illuminate all of the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that required two or more means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1027.1, in buildings required to have two or more exits. 5. Exterior landings as required by Section 1008.1.6 for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required: Where exit lighting is provided emergency lighting is also required at exterior side of door.
Misc
Resolved
05/01/2017

Unified Development Ordinance Article 7, Section 7.180.F Ground mounted equipment – Ground mounted equipment shall be totally screened from view by landscaping or masonry wall up to a height of the units to be screened. Action required: Make needed corrections to drawings that provide details as to how mechanical equipment will be screened per referenced UDO section. 5/1/17 - YARD IS FULLY FENCED
Fire Plan Review Approved 05/01/2017 04/25/2017
Joe Dir
Fire Plan Review Approved 04/24/2017 04/19/2017
Joe Dir
04/19/2017

04/19/2017

04/19/2017

Misc
Corrective Action Required
04/19/2017

All previous conditions were acknowledged and addressed in resubmittal
Building Plan Review Rejected 04/24/2017 04/19/2017
Joe Frogge
License Tax Application
Corrective Action Required
04/17/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 4/19/17 - acknowledged in letter
Code analysis required
Corrective Action Required
04/17/2017

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis. 4/19/17 - Provided. Make the following corrections: 1) This building is Type VB 2) Occupant load is 42
Misc
Resolved
04/19/2017

Inadequate information submitted. Provide the following: - Complete MEP designs. - Clarify use of Mech. Room. - Power to serve refrigerator and car lift. - Toilet room exhausts
Misc
Resolved
04/19/2017

2012 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Modify documents to demonstrate compliance at Toilet Room 110, and break room. 4/19/17 - toilet room 110 is existing
Accessibility - Fixed sidewall grab bars 604.5.1
Resolved
04/19/2017

ICC A117.1-2009 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Modify documents to show vertical side grab bars.
Bldg - Size of doors 1008.1.1
Resolved
04/19/2017

2012 IBC 1008.1.1 – Size of doors. The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of 32 inches. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Where this section requires a minimum clear width of 32 inches and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches. The maximum width of a swinging door leaf shall be 48 inches nominal. Means of egress doors in a Group i-2 occupancy used for the movement of beds shall provide a clear width not less than 41.5 inches. The height of door openings shall not be less than 80 inches. See Code for possible exceptions. Action required: Specify compliant door into Toilet 110. 4/19/17 - toilet room 110 is existing
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Resolved
04/19/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Maintain minimum 18" at latch side of door 2.3 into toilet room 110. 4/19/17 - toilet room 110 is existing
Bldg - Toilet room wall finish 1210.2.2
Corrective Action Required
04/17/2017

2012 IBC 1210.2.2 – Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finishes at restrooms and mop sink. (if paint is used, it must be epoxy based) 4/19/17 - Specify compliant wall finish at mop sink.
Plumb - Minimum number of fixtures 403.1
Resolved
04/19/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Misc
Corrective Action Required
04/17/2017

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles in service bays will by GFCI protected. 4/19/17 - Design provided, but not all relevant receptacles are protected.
Screening - Rooftop equipment
Corrective Action Required
04/19/2017

Unified Development Ordinance Article 7, Section 7.180.E Roof mounted equipment – All roof-mounted equipment shall be screened entirely from view by using parapet walls at the same height as the mechanical units. For additions to existing buildings that do not meet this standard, individual screens will be permitted, with the design subject to approval by the Director. Action required: Make needed corrections to drawings that provide details as to how roof mounted condensing units will be screened per referenced UDO section.
Misc
Corrective Action Required
04/19/2017

2012 IBC 1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed service equipment shall be used. In the absence of definite information, values used shall be subject to the approval of the building official. Action required: Provide verification that existing roof structure will support additional load imposed by condensing units.
Misc
Corrective Action Required
04/19/2017

2012 IPC 901.2 Trap seal protection. The plumbing system shall be provided with a system of vent piping that will permit the admission or emission of air so that the seal of any fixture trap shall not be subjected to a pneumatic pressure differential of more than 1 inch of water column. 901.2.1 Venting required. Traps and trapped fixtures shall be vented in accordance with one of the venting methods specified in this chapter. (see code for allowed methods) Action required: Provide vent at new water closet.
Misc
Corrective Action Required
04/19/2017

2011 NEC 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide receptacle near roof mounted condensing units.
Misc
Corrective Action Required
04/19/2017

2012 IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 2012 IBC 1006.3 – Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply illuminate all of the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that required two or more means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1027.1, in buildings required to have two or more exits. 5. Exterior landings as required by Section 1008.1.6 for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required: Where exit lighting is provided emergency lighting is also required at exterior side of door.
Licensed Contractors Rejected 04/17/2017 04/19/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
04/17/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor. 4/19/17 - acknowledged in letter
LC - MEP Subs
Corrective Action Required
04/17/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 4/19/17 - acknowledged in letter
Building Plan Review Rejected 03/09/2017 03/07/2017
Joe Frogge
License Tax Application
Corrective Action Required
03/07/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Code analysis required
Corrective Action Required
03/07/2017

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis.
Misc
Corrective Action Required
03/07/2017

Inadequate information submitted. Provide the following: - Complete MEP designs. - Clarify use of Mech. Room. - Power to serve refrigerator and car lift. - Toilet room exhausts
Misc
Corrective Action Required
03/07/2017

2012 IBC 1103.1 (Accessibility) Where required. Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to persons with physical disabilities. Action required: Modify documents to demonstrate compliance at Toilet Room 110, and break room.
Accessibility - Fixed sidewall grab bars 604.5.1
Corrective Action Required
03/07/2017

ICC A117.1-2009 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Modify documents to show vertical side grab bars.
Bldg - Size of doors 1008.1.1
Corrective Action Required
03/07/2017

2012 IBC 1008.1.1 – Size of doors. The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of 32 inches. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Where this section requires a minimum clear width of 32 inches and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches. The maximum width of a swinging door leaf shall be 48 inches nominal. Means of egress doors in a Group i-2 occupancy used for the movement of beds shall provide a clear width not less than 41.5 inches. The height of door openings shall not be less than 80 inches. See Code for possible exceptions. Action required: Specify compliant door into Toilet 110.
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Corrective Action Required
03/07/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Maintain minimum 18" at latch side of door 2.3 into toilet room 110.
Bldg - Toilet room wall finish 1210.2.2
Corrective Action Required
03/07/2017

2012 IBC 1210.2.2 – Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant wall finishes at restrooms and mop sink. (if paint is used, it must be epoxy based)
Plumb - Minimum number of fixtures 403.1
Corrective Action Required
03/07/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Misc
Corrective Action Required
03/07/2017

2011 NEC 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas where electrical diagnostic equipment, electrical hand tools, or portable lighting equipment are to be used. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles in service bays will by GFCI protected.
Licensed Contractors Rejected 03/09/2017 03/07/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
03/07/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
03/07/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 03/09/2017 03/01/2017
Joe Dir
Address numbers required
Corrective Action Required
03/01/2017

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Post the numeric address of 403 in a contrasting color to the background. Address shall be readable from the roadway.
Portable fire extinguishers - general
Corrective Action Required
03/01/2017

2012IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide a minimum of two 2A-10BC fire extinguishers (rated 5 pounds)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
03/01/2017

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. ACTION REQUIRED: (Verified at inspection) Mount the fire extinguishers on a normal path of travel to an exit, with a maximum travel distance to a extinguisher of 75 feet.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $265.53 $265.53 Paid 05/09/2017
8331507-Sewer Connection Fee $180.00 $180.00 Paid 05/09/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 5/10/2017 5/10/2017 05/10/2017
Underslab Electrical Inspection - Commercial Passed 05/10/2017
All Rough Inspection - Commercial Failed 5/26/2017 5/26/2017 05/26/2017
Misc
Corrective Action Required
05/26/2017
-INSTALL PLUMBING PROTECTION THROUGHOUT -MISSING TWO J BOXES MIDDLE ROOM -SECURE MC CABLE AT BOXES
All Rough Inspection - Commercial Failed 6/2/2017 6/2/2017 06/02/2017
Misc
Corrective Action Required
05/26/2017
-INSTALL PLUMBING PROTECTION AT SOLE- AND TOP-PLATES (BOCA PLATES NEEDED) *OK TO HANG ROCK AT ALL LOCATIONS EXCEPT WHERE BOCA PLATES ADDED.
All Rough Inspection - Commercial Passed 6/5/2017 6/5/2017 06/05/2017
Misc
Resolved
06/05/2017
-INSTALL PLUMBING PROTECTION AT SOLE- AND TOP-PLATES (BOCA PLATES NEEDED) *OK TO HANG ROCK AT ALL LOCATIONS EXCEPT WHERE BOCA PLATES ADDED.
Electrical Service Inspection Not Ready 6/28/2017 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
*NOT READY* New CT cabinet has been mounted; no wiring yet installed. No one present on-site.
Electrical Service Inspection Failed 6/29/2017 6/29/2017 06/29/2017
Misc
Corrective Action Required
06/28/2017
Existing ground wires do no match plan. Electrician will contact Engineer to get resolved; then call in for re-inspection. Service not released.
Electrical Service Inspection Passed 6/30/2017 06/30/2017
Misc
Resolved
06/30/2017
Existing ground wires do no match plan. Electrician will contact Engineer to get resolved; then call in for re-inspection. Service not released.
Above Ceiling Inspection Passed 7/11/2017 07/11/2017
Occupancy Inspection - Codes Commercial Full C of O 8/10/2017 8/10/2017 08/10/2017
Occupancy Inspection - Fire Passed 8/10/2017 08/10/2017
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit