Summary
PRCOM20161538
Building Permit - Commercial
Final Completion
WOODS CHAPEL CHURCH OF GOD
REPAIR REPLACE UPGRADE
INSTALL UNDERGROUND ELEC SERVICE
06/27/2016
06/27/2016
08/12/2016
Locations
Contacts
WOODS CHAPEL CHURCH OF GOD, Address:1150 NE WOODS CHAPEL RD  
TEAGUE ELECTRIC CONSTRUCTION LLC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/27/2016 06/27/2016
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Repair/Replace/Upgrade $30.00 $30.00 Paid 06/27/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 7/21/2016 07/21/2016
Misc
Corrective Action Required
07/21/2016
-INSTALL THE MAIN BONDING JUMPER FROM GROUNDING BUS BAR, WHERE THE GROUNDING ELECTRODE CONDUCTORS ARE CONNECTED TO, TO THE GROUNDED BUS BAR ABOVE. NEC 250.24(A)(4) -EXPOSE THE TWO GROUNDING CONNECTIONS TO RODS
Electrical Service Inspection Passed 8/12/2016 8/12/2016 08/12/2016
Misc
Resolved
08/12/2016
-INSTALL THE MAIN BONDING JUMPER FROM GROUNDING BUS BAR, WHERE THE GROUNDING ELECTRODE CONDUCTORS ARE CONNECTED TO, TO THE GROUNDED BUS BAR ABOVE. NEC 250.24(A)(4) -EXPOSE THE TWO GROUNDING CONNECTIONS TO RODS
Final Electrical Inspection - Commercial Passed 08/12/2016
Documents & Images
Date Uploaded File Type Document Name
06/27/2016 Receipt Receipt for transaction: 2016-004180
06/27/2016 Letter Codes Building Permit
06/29/2016 Scope of Work DOC062916-012
07/21/2016 Letter Inspection Summary
08/12/2016 Letter Inspection Summary
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:
Browse..





    Portal Home