Permit Application Status

PRCOM20150850


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20150850
Building Permit - Commercial
Final Completion
CITY OF LEES SUMMIT
PARTIAL COMMERCIAL
FOUNDATION & UNDERSLAB ONLY FULL PERMIT - PRCOM20150658
04/21/2015
05/01/2015
10/16/2015
Locations
Contacts
THOMPSON BUILDERS LLC, Address:4559 GROVE ST, Phone:(913) 915-2836  
CITY OF LEES SUMMIT, Address:PO BOX 1600  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/30/2015
Mike Weisenborn
Building Plan Review Approved 04/30/2015
Mike Weisenborn
Licensed Contractors Approved 04/21/2015 04/21/2015
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Partial Commercial $255.68 $255.68 Paid 05/01/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 5/11/2015 at 12:00 AM 05/11/2015
THE FOLLOWING AREAS ARE APPROVED
Partial Correction
05/11/2015
GRADE BEAMS AND PADS OK TO POUR AT THE FOLLOWING: -EAST LINE FROM H TO SE CORNER; FROM SE CORNER TO LINE 2
Footing Inspection - Commercial Failed 5/12/2015 (1:00) 5/12/2015 at 12:00 AM 05/12/2015
THE FOLLOWING AREAS ARE APPROVED
Partial Correction
05/11/2015
GRADE BEAMS AND PADS OK TO POUR AT THE FOLLOWING: -EAST LINE FROM H TO SE CORNER; FROM SE CORNER TO LINE 2 **THE EAST GRADE BEAM REBAR NOT PER PLAN **CLEAN OUT ALL LOOSE DIRT THAT FELL DOWN **PROVIDE MIN. 1.5" CLEARANCE FROM REBAR TO SOIL NEAR NE CORNER
Footing Inspection - Commercial Passed 5/12/2015 (3:00) 5/12/2015 at 12:00 AM 05/12/2015
THE FOLLOWING AREAS ARE APPROVED
Resolved
05/12/2015
GRADE BEAMS AND PADS OK TO POUR AT THE FOLLOWING: -EAST LINE FROM H TO SE CORNER; FROM SE CORNER TO LINE 2 **THE EAST GRADE BEAM REBAR NOT PER PLAN **CLEAN OUT ALL LOOSE DIRT THAT FELL DOWN **PROVIDE MIN. 1.5" CLEARANCE FROM REBAR TO SOIL NEAR NE CORNER **EXTEND GRADE BEAM REBAR TO PADS
Underslab Plumbing Inspection - Commercial Passed 5/26/2015 at 12:00 AM 05/26/2015
Documents & Images
Date Uploaded File Type Document Name
05/01/2015 Letter Codes Building Permit
05/01/2015 Receipt Receipt for transaction: 2015-000730
05/11/2015 Letter Inspection Summary
05/12/2015 Letter Inspection Summary
05/12/2015 Letter Inspection Summary
05/26/2015 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home