Summary
PRCOM20140191
Building Permit - Commercial
Certificate of Occupancy
DACUR INVESTMENT COMPANY INC
ALTERATION COMMERCIAL
EXPAND EXISTING TENANT SPACE lock box: tng
02/18/2014
04/29/2014
08/24/2014
08/21/2014
Locations
Contacts
LUKE DRAILY CONSTRUCTION INC, Address:75 NW BUSINESS PARK LANE, Phone:(816) 459-8531  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
SCHARHAG ARCHITECTS, Address:310 ARMOUR RD #202, Phone:(816) 221-9297  
DACUR INVESTMENT COMPANY INC, Address:2700 KENDALLWOOD PKWY # 208  
BUCKNER'S HEATING & COOLING LLC, Address:8576 N GREEN HILLS RD, Phone:(816) 436-1244  
WIRKEN ELECTRIC, Address:301 W 73RD ST, Phone:(816) 333-9828  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 04/30/2014 04/29/2014
Joe Frogge
Business License
Corrective Action Required
03/31/2014

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Either a Class A or Class B license is required. Provide the name of the licensed general contractor. Required Action: Provide name of General Contractor.
License contractors
Corrective Action Required
03/31/2014

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Required Action: Provide names of MEP subs as applicable.
Fire Plan Review Approved 04/07/2014 04/10/2014
Brian Austerman
Address numbers required
Corrective Action Required
03/31/2014

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Address all exterior doors to match the business, verified at inspection
Portable fire extinguishers - general
Corrective Action Required
03/31/2014

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a 2A10B:C type extinguisher (5 pound) for every 3,000 square feet. Verified at inspection
Misc
Corrective Action Required
03/31/2014

1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. Provide emergency lighting if not already existing
Misc
Corrective Action Required
03/31/2014

1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in a corridor is more than 100 feet (30 480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Exceptions: 1. Exit signs are not required in rooms or areas that require only one exit or exit access. 2. Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official. 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3. 4. Exit signs are not required in sleeping areas in occupancies in Group I-3. 5. In occupancies in Groups A-4 and A-5, exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Provide exit signage if not already existing
Fire-resistant-rated construction - Maintenance
Corrective Action Required
04/10/2014

2012 IFC 703.1- Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Provide firestopping if needed for any penetrations through the cmu wall
Building Plan Review Approved 04/07/2014 04/08/2014
Joe Frogge
Building Plan Review Approved 02/28/2014 02/24/2014
Joe Frogge
Licensed Contractors Rejected 02/28/2014 02/24/2014
Joe Frogge
Business License
Corrective Action Required
02/24/2014

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Either a Class A or Class B license is required. Provide the name of the licensed general contractor. Required Action: Provide name of General Contractor.
License contractors
Corrective Action Required
02/24/2014

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Required Action: Provide names of MEP subs as applicable.
Fire Plan Review Rejected 02/28/2014 02/20/2014
Brian Austerman
Misc
Corrective Action Required
02/20/2014

2014 IFC 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one of the following conditions exists: 1. A Group M fire area exceeds 12,000 square feet (1115m2). 2. A Group M fire area is located more than two stories above grade plane. 3. The combined area of all Group M fire areas on all floors, including mezzanines, exceeds 24,000 square feet (2230m2). 4. A Group M occupancy used for the dispaly and sale of upholstered furnature or mattresses exceeds 5,000 square feet (464 m2). By removing the wall between the two occupancies the Group M fire area is over 12,000 square feet. This will require sprinklering of the entire Group M area, or constructing a fire separation area within the space to maintain the area under 12,000 square feet. The vacant space was an A-3 occupancy, with the change in use to that of an M this rule shall apply. Please provide details on either sprinklering the space or separating it out.
Address numbers required
Corrective Action Required
02/24/2014

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Address all exterior doors to match the business, verified at inspection
Portable fire extinguishers - general
Corrective Action Required
02/24/2014

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a 2A10B:C type extinguisher (5 pound) for every 3,000 square feet. Verified at inspection
Misc
Corrective Action Required
02/24/2014

1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. Provide emergency lighting if not already existing
Misc
Corrective Action Required
02/24/2014

1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in a corridor is more than 100 feet (30 480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Exceptions: 1. Exit signs are not required in rooms or areas that require only one exit or exit access. 2. Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official. 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3. 4. Exit signs are not required in sleeping areas in occupancies in Group I-3. 5. In occupancies in Groups A-4 and A-5, exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Provide exit signage if not already existing
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $92.37 $92.37 Paid 04/29/2014
$92.37
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Failed 5/20/2014 (8:00 to 5:00) 5/20/2014 at 12:00 AM 05/20/2014
Misc
Corrective Action Required
05/20/2014
SOUTH WALL @ 56' EAST END EXPANSION SPACE: NEC 300-11, 330.30 & 334-10 INSTALLATION OF MC ELECTRICAL CABLE: NOT SECURELY FASTENED WITHIN 12" OF ENTRY TO BOXES. DO NOT COVER.
Misc
Corrective Action Required
05/20/2014
WALL IN-FILL @ EAST WALL NE CORNER: DRAWING CALLS FOR STEEL FRAMING -- NOT WOOD. DO NOT COVER
In-wall Inspection Partial 5/22/2014 5/22/2014 at 12:00 AM 05/22/2014
Misc
Corrective Action Required
05/20/2014
SOUTH WALL @ 56' EAST END EXPANSION SPACE: NEC 300-11, 330.30 & 334-10 INSTALLATION OF MC ELECTRICAL CABLE: NOT SECURELY FASTENED WITHIN 12" OF ENTRY TO BOXES. DO NOT COVER.
Misc
Resolved
05/22/2014
WALL IN-FILL @ EAST WALL NE CORNER: DRAWING CALLS FOR STEEL FRAMING -- NOT WOOD. DO NOT COVER
In-wall Inspection Passed 5/23/2014 5/23/2014 at 12:00 AM 05/23/2014
Misc
Resolved
05/23/2014
SOUTH WALL @ 56' EAST END EXPANSION SPACE: NEC 300-11, 330.30 & 334-10 INSTALLATION OF MC ELECTRICAL CABLE: NOT SECURELY FASTENED WITHIN 12" OF ENTRY TO BOXES. DO NOT COVER.
Above Ceiling Inspection Not Ready 6/6/2014 6/6/2014 at 12:00 AM 06/06/2014
Misc
Corrective Action Required
06/06/2014
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
Above Ceiling Inspection Partial 6/10/2014 6/10/2014 at 12:00 AM 06/10/2014
Misc
Resolved
06/10/2014
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
Misc
Partial Correction
06/10/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: EAST EXPANSION AREA EXCEPT @ NW CORNER WHERE EXISTING PVC ROOF DRAIN IS PRESENT IN ABOVE-CEILING PLENUM
Occupancy Inspection - Codes Commercial Partial 6/19/2014 6/19/2014 at 12:00 AM 06/19/2014
Misc
Partial Correction
06/19/2014
CHECK ALL ELECTRICAL RECEPTACLES; ENSURE NONE ARE "SOFT" OR LOOSE SIDE-TO-SIDE.
Misc
Partial Correction
06/19/2014
RESOLVE FIRE DEPT ISSUES
Misc
Partial Correction
06/19/2014
SUBJECT TO REVIEW OF PERMIT DRAWINGS NOT ON SITE, OK TO MOVE MERCHANDISE INTO EAST EXPANSION SPACE; BUT DO NOT OBSTRUCT ELECTRICAL RECEPTACLES UNTIL THEY ARE APPROVED.
Occupancy Inspection - Fire Temporary C of O 6/19/2014 6/19/2014 at 12:00 AM 06/19/2014
Misc
Corrective Action Required
06/19/2014
- address fron and rear doors of new area as "901" - mount one 2A-10BC fire extinguisher at the front entrance and rear exit - rated storage area must be constructed before sepration wall is taken down.
In-wall Inspection Partial 7/8/2014 7/8/2014 at 12:00 AM 07/08/2014
Misc
Partial Correction
07/08/2014
AT NEW STORAGE ROOM WALLS OK TO HANG GWB EXCEPT AT HVAC DUCT PENETRATONS OF WALL. A/E TO CONSULT WITH LS CODES PLAN REVIEW TO DETERMINE WHETHER DAMPERS ARE REQUIRED -- AND TYPE. WRITTEN RESOLUTION REQUIRED.
Occupancy Inspection - Codes Commercial Partial 7/10/2014 at 12:00 AM 07/10/2014
Misc
Resolved
07/10/2014
CHECK ALL ELECTRICAL RECEPTACLES; ENSURE NONE ARE "SOFT" OR LOOSE SIDE-TO-SIDE.
Misc
Partial Correction
06/19/2014
RESOLVE FIRE DEPT ISSUES
Misc
Partial Correction
06/19/2014
OK TO MOVE MERCHANDISE INTO EAST EXPANSION SPACE;
Rated Assembly Inspection Partial 7/15/2014 7/15/2014 at 12:00 AM 07/15/2014
Misc
Partial Correction
07/15/2014
NEW UL419 WALLS OF DELIVERY SPACE: - NORTH WALL OK TO TAPE, MUD, AND FIRE-SEAL BOTH FACES - EAST WALL EAST FACE OK TO TAPE, MUD, AND FIRE-SEAL FULL HEIGHT TO DECK; WEST FACE OK TO TAPE, MUD, AND FIRE-SEAL TO CEILING ELEVATION
Investigation Inspection Complete 7/16/2014 at 12:00 AM 07/16/2014
Rated Assembly Inspection Partial 7/18/2014 at 12:00 AM 07/18/2014
Misc
Partial Correction
07/15/2014
NEW UL419 WALLS OF DELIVERY SPACE: - NORTH WALL OK TO TAPE, MUD, AND FIRE-SEAL BOTH FACES - EAST WALL EAST FACE AND WEST FACE OK TO TAPE, MUD, AND FIRE-SEAL FULL HEIGHT TO DECK
Miscellaneous Inspection Passed 7/18/2014 at 12:00 AM 07/18/2014
Above Ceiling Inspection Partial 7/28/2014 7/28/2014 at 12:00 AM 07/28/2014
Misc
Partial Correction
06/10/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: EAST EXPANSION AREA; NEW STORAGE ROOM RATED WALL APPROVED BOTH FACES, BUT FULL ABOVE-CEILING INSPECTION YET TO BE PERFORMED
Above Ceiling Inspection Partial 7/28/2014 at 12:00 AM 07/28/2014
Misc
Partial Correction
07/28/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: EAST EXPANSION AREA; NEW STORAGE ROOM RATED WALL APPROVED BOTH FACES. HVAC FLEX DUCT NOT SUPPORTED TO ROOF STRUCTURE. SUPPORT PER SMACNA/AIR DIFFUSION COUNCIL STANDARDS.
Occupancy Inspection - Codes Commercial Partial 7/30/2014 at 12:00 AM 07/30/2014
Misc
Partial Correction
07/10/2014
RESOLVE FIRE DEPT ISSUES
Misc
Partial Correction
07/10/2014
OK TO MOVE MERCHANDISE INTO EAST EXPANSION SPACE; RATED WALLS AT NEW STORAGE ROOM APPROVED (ABOVE-CEILING NOT YET APPROVED) SO OK TO DEMO EXISTING WALL BETWEEN EXISTING STORE AREA AND NEW EAST EXPANSION SPACE;
Miscellaneous Inspection Passed 7/30/2014 at 12:00 AM 07/30/2014
Above Ceiling Inspection Partial 8/8/2014 8/8/2014 at 12:00 AM 08/08/2014
Misc
Resolved
08/08/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: EAST EXPANSION AREA; NEW STORAGE ROOM RATED WALL APPROVED BOTH FACES. HVAC FLEX DUCT NOT SUPPORTED TO ROOF STRUCTURE. SUPPORT PER SMACNA/AIR DIFFUSION COUNCIL STANDARDS.
Misc
Partial Correction
08/08/2014
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS EVERWHERE EXCEPT NORTH 20' WHERE DEMISING WALL WAS REMOVED WHERE MULTIPLE ELECTRICAL ISSUES REMAIN.
Occupancy Inspection - Codes Commercial Full C of O 8/21/2014 8/21/2014 at 12:00 AM 08/21/2014
Misc
Resolved
08/21/2014
RESOLVE FIRE DEPT ISSUES
Misc
Resolved
08/21/2014
OK TO MOVE MERCHANDISE INTO EAST EXPANSION SPACE; RATED WALLS AT NEW STORAGE ROOM APPROVED (ABOVE-CEILING NOT YET APPROVED) SO OK TO DEMO EXISTING WALL BETWEEN EXISTING STORE AREA AND NEW EAST EXPANSION SPACE;
Above Ceiling Inspection Passed 8/8/2014 at 12:00 AM 08/21/2014
In-wall Inspection Passed 7/8/2014 at 12:00 AM 08/21/2014
Misc
Resolved
08/21/2014
AT NEW STORAGE ROOM WALLS OK TO HANG GWB EXCEPT AT HVAC DUCT PENETRATONS OF WALL. A/E TO CONSULT WITH LS CODES PLAN REVIEW TO DETERMINE WHETHER DAMPERS ARE REQUIRED -- AND TYPE. WRITTEN RESOLUTION REQUIRED.
Rated Assembly Inspection Passed 7/18/2014 at 12:00 AM 08/21/2014
Misc
Resolved
08/21/2014
NEW UL419 WALLS OF DELIVERY SPACE: - NORTH WALL OK TO TAPE, MUD, AND FIRE-SEAL BOTH FACES - EAST WALL EAST FACE AND WEST FACE OK TO TAPE, MUD, AND FIRE-SEAL FULL HEIGHT TO DECK
Occupancy Inspection - Fire Passed 8/21/2014 8/21/2014 at 12:00 AM 08/21/2014
Misc
Corrective Action Required
06/19/2014
- address fron and rear doors of new area as "901" - mount one 2A-10BC fire extinguisher at the front entrance and rear exit - rated storage area must be constructed before sepration wall is taken down.
Documents & Images
Date Uploaded File Type Document Name
02/24/2014 Letter Fire Building Plan Review
02/24/2014 Letter Codes P/R Corrections Document
04/10/2014 Letter Fire (Sprinkler) Plan Review
04/29/2014 Letter Codes Plan Review Conditions
04/29/2014 Letter Codes Building Permit
05/20/2014 Letter Inspection Summary
05/22/2014 Letter Inspection Summary
05/23/2014 Letter Inspection Summary
06/06/2014 Letter Inspection Summary
06/10/2014 Letter Inspection Summary
06/19/2014 Letter Inspection Summary
07/08/2014 Letter Inspection Summary
07/15/2014 Letter Inspection Summary
07/18/2014 Letter Inspection Summary
07/28/2014 Letter Inspection Summary
07/28/2014 Letter Inspection Summary
07/30/2014 Letter Inspection Summary
08/08/2014 Letter Inspection Summary
08/18/2014 Letter Fire Loss Reduction Form
08/21/2014 Letter Field Certificate of Occupancy
08/22/2014 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home