Summary
PRCOM20131734
Building Permit - Commercial
Final Completion
JEFFREY E SMITH INV CO LC
NEW OTHER (COMMERCIAL)
TEMPORARY ELECTRIC SERVICE
08/12/2013
08/12/2013
08/21/2013
Locations
Contacts
BRINTON ELECTRIC COMPANY INC, Address:10100 E 65TH ST STE B, Phone:(816) 356-0922  
JEFFREY E SMITH INV CO LC, Address:PO BOX 7688  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 08/12/2013 08/12/2013
Codes Admin
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $30.00 $30.00 Paid 08/12/2013
$30.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 8/15/2013 8/15/2013 at 12:00 AM 08/15/2013
Misc
Corrective Action Required
08/15/2013
**NOTE: TEMPORARY SERVICE STILL MUST COMPLY PER NEC 590. -DRIVE GROUNDING ROD FLUSH TO GROUND; 2 GROUNDING RODS SEPARATED BY MINIMUM 6 FT REQUIRED PER NEC 250.56 -RIGID NONMETALLIC CONDUIT CANNOT BE EXPOSED TO PHYSICAL DAMAGE -BOND THE METAL FITTING BETWEEN METER ENCLOSURE AND SERVICE DISCONNECT PER NEC250.92 WITH BONDING BUSHING, BONDING LOCKNUT, OR OTHER APPROVED MEANS -SHALL GROUND METAL STRUCTURE PER CODE. NEC 250.32 AND NEC 250.104 -PROVIDE ACCESS TO SUBPANEL **YOU LEFT A MESSAGE BUT DID NOT LEAVE THE LAST 2 PHONE NUMBER DIGITS
Electrical Service Inspection Failed 8/20/2013 8/20/2013 at 12:00 AM 08/20/2013
Misc
Corrective Action Required
08/15/2013
-SHALL GROUND METAL STRUCTURE PER CODE. NEC 250.32 AND NEC 250.104 **250.32 BUILDING/STRUCTURE SUPPLIED BY FEEDER 250.32(A) REQUIRES THAT THIS STRUCTURE (CONSTRUCTION OFFICE BOX) HAS ITS OWN GROUNDING ELECTRODE INSTALLED. 250.32(B)(1) REQUIRES THAT THE FEEDER EQUIPMENT GROUNDING CONDUCTOR TO BE CONNECTED TO THE GROUNDING ELECTRODE (NOT INSTALLED) AND TO BOND EQUIPMENTS AND STRUCTURE (WHICH IT DOES) THE METAL STRUCTURE IS BONDED TO THE SUBPANEL ENCLOSURE. THE CONNECTION IS OUTSIDE NEAR THE FEEDER POINT OF ENTRY. THIS MEETS THE REQUIREMENT OF 250.104
Electrical Service Inspection Passed 8/21/2013 8/21/2013 at 12:00 AM 08/21/2013
Misc
Resolved
08/21/2013
-SHALL GROUND METAL STRUCTURE PER CODE. NEC 250.32 AND NEC 250.104 **250.32 BUILDING/STRUCTURE SUPPLIED BY FEEDER 250.32(A) REQUIRES THAT THIS STRUCTURE (CONSTRUCTION OFFICE BOX) HAS ITS OWN GROUNDING ELECTRODE INSTALLED. 250.32(B)(1) REQUIRES THAT THE FEEDER EQUIPMENT GROUNDING CONDUCTOR TO BE CONNECTED TO THE GROUNDING ELECTRODE (NOT INSTALLED) AND TO BOND EQUIPMENTS AND STRUCTURE (WHICH IT DOES) THE METAL STRUCTURE IS BONDED TO THE SUBPANEL ENCLOSURE. THE CONNECTION IS OUTSIDE NEAR THE FEEDER POINT OF ENTRY. THIS MEETS THE REQUIREMENT OF 250.104
Final Electrical Inspection - Commercial Passed 08/21/2013
Documents & Images
Date Uploaded File Type Document Name
08/12/2013 Letter Codes Building Permit
08/12/2013 Scope of Work
08/15/2013 Letter Inspection Summary
08/20/2013 Letter Inspection Summary
08/21/2013 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home