Permit Application Status

PRCOM20131711


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20131711
Building Permit - Commercial
Voided
Summit Development Co
CHANGE OF TENANT
TENANT FINISH FOR DRY CLEANER DROP OFF
08/08/2013
04/29/2015
Locations
Contacts
Summit Development Co, Address:700 W 47th St Ste 200  
PRIDE CLEANERS, Address:13613 S US 71 HWY, Phone:(816) 347-7464  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 08/20/2013 08/19/2013
Mike Weisenborn
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
08/19/2013

2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - Compliance for the accessible sales counter will be verified at inspection.
Plumb - Required public toilet facilities
Corrective Action Required
08/19/2013

2006 IPC 403.4 - Required public toilet facilities. Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The accessible route to public facilities shall not pass through kitchens, storage rooms, closets or similar spaces. Employees shall be provided with toilet facilities in all occupancies. Employee toilet facilities shall be either separate or combined employee and public toilet facilities. Action required - The comment is for information purposes.
Fire Plan Review Approved with Conditions 08/20/2013 08/09/2013
Jim Eden
Address numbers required
Corrective Action Required
08/09/2013

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Verified at inspection.
Portable fire extinguishers - general
Corrective Action Required
08/09/2013

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Verified at inspection. Provide a minimum 2A:10B: C fire extinguisher in a conspicuous location.
Misc
Corrective Action Required
08/09/2013

All existing conditions are subject to inspection. Any condition not meeting current code, or the code in place at the time of original occupancy, shall be corrected.
Licensed Contractors Approved 08/20/2013 08/09/2013
Mike Weisenborn
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
08/14/2013 Letter Fire Building Plan Review
08/19/2013 Letter Codes Plan Review Conditions
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home