Summary
PRCOM20122737
Building Permit - Commercial
Final Completion
DRIENIK INVESTMENTS L L C
ALTERATION COMMERCIAL
SOLAR PANEL INSTALLATION - 21.00 KW SYSTEM
12/17/2012
01/07/2013
01/09/2013
Locations
Contacts
WACHTER INC, Address:16001 W 99TH ST, Phone:(913) 541-2500  
DRIENIK INVESTMENTS L L C, Address:1018 SE BROWNING  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Com) Approved 12/31/2012 01/03/2013
Mike Weisenborn
True
Fire Plan Review Approved with Conditions 12/31/2012 12/28/2012
Jim Eden
Misc
Corrective Action Required
12/28/2012

605.11.3.3.1 Access. There shall be a minimum 6- foot-wide (1829 mm) clear perimeter around the edges of the roof. Exception: Where either axis of the building is 250 feet (76 200 mm) or less, there shall be a minimum 4-foot-wide (1290 mm) clear perimeter around the edges of the roof. Building dimensions are not shown on plans, however cursory determination is that this appears to be close. In future drawings include building dimensions to allow for proper determination
Misc
Corrective Action Required
12/28/2012

605.11.1 Marking. Marking is required on interior and exterior direct-current (DC) conduit, enclosures, raceways, cable assemblies, junction boxes, combiner boxes and disconnects 605.11.1.2 Marking content. The marking shall contain the words “WARNING: PHOTOVOLTAIC POWER SOURCE.” Action Required: Conduits, raceways, boxes and disconnects shal be labeled as shown above, verified at inspection.
Misc
Corrective Action Required
12/28/2012

605.11.1.4 Location of marking. Marking shall be placed on interior and exterior DC conduit, raceways, enclosures and cable assemblies every 10 feet (3048 mm), within 1 foot (305 mm) of turns or bends and within 1 foot (305 mm) above and below penetrations of roof/ceiling assemblies, walls or barriers. Marking locations will be verified at inspection
Misc
Corrective Action Required
12/28/2012

2006 IFC- Section 102.7 Subjects not regulated by this code. Where no applicable standards or requirements are set forth in this code, or are contained within other laws, codes, regulations, ordinances or bylaws adopted by the jurisdiction, compliance with applicable standards of the National Fire Protection Association or other nationally recognized fire safety standards, as approved, shall be deemed as prima facie evidence of compliance with the intent of this code. Nothing herein shall derogate from the authority of the fire code official to determine compliance with codes or standards for those activities or installations within the fire code official’s jurisdiction or responsibility. 102.8 Matters not provided for. Requirements that are essential for the public safety of an existing or proposed activity, building or structure, or for the safety of the occupants thereof, which are not specifically provided for by this code shall be determined by the fire code official. For information only- The 2006 International Fire Code (IFC) is adopted as the Fire Code for the City of Lee's Summit, but it does not address photovoltaic systems (PV). The 2012 IFC does address PV systems and is being reviewed for adoption. The 2012 IFC will be the reference document for this project.
Building Plan Review Approved 12/31/2012 12/26/2012
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Alteration to Commercial $110.52 $110.52 Paid 01/07/2013
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Electrical Inspection - Commercial Passed 1/9/2013 (8:00 to 5:00) 1/9/2013 at 12:00 AM 01/09/2013
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit