Permit Application Status

PRCOM20122619


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20122619
Building Permit - Commercial
Certificate of Occupancy
VILLE 36 INVESTMENT COMPANY LLC
CHANGE OF TENANT
CHANGE OF TENANT JUSTICE & BROTHERS
11/27/2012
04/29/2013
10/15/2014
07/01/2013
Locations
Contacts
VILLE 36 INVESTMENT COMPANY LLC, Address:4740 ROANOKE PKWY  
TRI-NORTH BUILDERS INC, Address:PO BOX 259568, Phone:(608) 271-8717  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ROZIER ELECTRIC, Address:1608 SW JEFFERSON ST, Phone:(816) 246-9000  
RIDEN SERVICE CO INC, Address:11306 W 89TH ST, Phone:(913) 432-8495  
ABBOT STUDIOS, Address:130 E CHESTNUT ST  
SUMMIT WOODS SPE LLC, Address:1 E WASHINGTON ST STE 300  
Reviews
Review Type Outcome Est. Completion Date Completed
Sprinkler Plan Review Released for Construction 05/22/2013
Brian Austerman
Misc
Corrective Action Required
05/22/2013

Plans received 5/22/2013, approved same date
License Tax Codes Approved 06/05/2013 04/29/2013
Codes Admin
Licensed Contractors Approved 06/05/2013 04/29/2013
Codes Admin
Building Plan Review Approved 01/03/2013 01/03/2013
Mike Weisenborn
Business License
Corrective Action Required
12/26/2012

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Provide the name of the licensed general contractor for the project. A minimum of a Class B license is required.
License contractors
Corrective Action Required
12/26/2012

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - Provide the names of the licensed mechanical, electrical and plumbing sub-contractors.
Bldg - Means of egress illumination - Emergency power
Resolved
01/03/2013

2006 IBC 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas. 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in building required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in building required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required - Item 5 requires emergency lighting on the exterior of the building at the egress points. If it is not already provided it needs to be added into this project. This comment is for informaiton purposes and will be verified on inspection.
Fire Plan Review Approved with Conditions 01/03/2013 12/27/2012
Brian Austerman
Misc
Corrective Action Required
12/27/2012

Approved as per prior listed conditions and revisions
Internal Plan Review (Res) Rejected 12/07/2012 12/07/2012
Mike Weisenborn
Building Plan Review Rejected 12/07/2012 12/07/2012
Mike Weisenborn
Business License
Corrective Action Required
12/07/2012

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Provide the name of the licensed general contractor for the project. A minimum of a Class B license is required.
License contractors
Corrective Action Required
12/07/2012

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - Provide the names of the licensed mechanical, electrical and plumbing sub-contractors.
Bldg - Means of egress illumination - Emergency power
Corrective Action Required
12/07/2012

2006 IBC 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas. 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in building required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in building required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required - Item 5 requires emergency lighting on the exterior of the building at the egress points. If it is not already provided it needs to be added into this project. This comment is for informaiton purposes and will be verified on inspection.
Zoning Review Approved 12/07/2012 12/07/2012
Mike Weisenborn
Fire Plan Review Approved with Conditions 12/07/2012 11/28/2012
Brian Austerman
Address numbers required
Corrective Action Required
11/28/2012

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ALL EXTERIOR DOORS TO THE SPACE SHALL HAVE PROPER ADDRESSING, VERIFIED AT INSPECTION
Portable fire extinguishers - conspicuous locations
Corrective Action Required
11/28/2012

2006 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. PROVIDE A MINIMUM OF TWO 2A10B:C FIRE EXTINGUISHERS, VERIFIED AT INSPECTION
Misc
Corrective Action Required
11/28/2012

1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. THUMB LATCH OR PANIC HARDWARE SHALL BE USED ON EXIT DOORS, VERIFIED AT INSPECTION
Misc
Corrective Action Required
11/28/2012

1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in buildings required to have two or more exits. PROVIDE EMERGENCY EXTERIOR EGRESS LIGHTING IF NOT ALREADY EXISTING
Misc
Corrective Action Required
11/28/2012

907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. FOR UNITS OVER 2,000 CFM. FOR INFORMATION ONLY
Misc
Corrective Action Required
11/28/2012

APPLICABLE CODE IS THE 2006 IFC, FOR INFORMATION ONLY
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $861.94 $861.94 Paid 04/29/2013
$861.94
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Electrical Inspection - Commercial Passed 5/7/2013 5/7/2013 at 12:00 AM 05/07/2013
Underslab Plumbing Inspection - Commercial Passed 5/7/2013 at 12:00 AM 05/07/2013
In-wall Inspection Partial 5/8/2013 5/8/2013 at 12:00 AM 05/08/2013
Misc
Partial Correction
05/08/2013
OK TO COVER WHEN READY WALL FRAMING + IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: DEMISING WALL AT NON-SALES EAST;
In-wall Inspection Partial 5/10/2013 5/10/2013 at 12:00 AM 05/10/2013
Misc
Partial Correction
05/08/2013
OK TO COVER WHEN READY WALL FRAMING + IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: DEMISING WALL AT NON-SALES EAST; BOTH LAVS BOTH FACES OF WALLS; 8" FALSE WALL BUMP-OUT AT CENTER OF JUSTICE SALES W WALL;
Above Ceiling Inspection Failed 5/30/2013 5/30/2013 at 12:00 AM 05/30/2013
Misc
Partial Correction
05/10/2013
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: BOTH LAVS;
Misc
Corrective Action Required
05/10/2013
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES:
Misc
Corrective Action Required
05/30/2013
PHASE 1 AREA CEILING ALREADY TILED; NOT READY FOR INSPECTION PHASE 2 AREA: - REMOVE CEILING TILE EXCEPT FEW ALLOWED - SECURE MC ELECT CABLE W/I 12" OF BOXES - PLUG ANY UNUSED J-BOX OPENINGS - CLOSE ALL J-BOXES - REMOVE ALL ABANDONED HANGERS, ETC
Occupancy Inspection - Codes Commercial Not Ready 5/30/2013 at 12:00 AM 05/30/2013
Misc
Corrective Action Required
05/30/2013
PHASE 1 AREA HAS BEEN OCCUPIED WITHOUT INSPECTION/APPROVAL
Above Ceiling Inspection Partial 6/3/2013 6/3/2013 at 12:00 AM 06/03/2013
Misc
Partial Correction
05/30/2013
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: BOTH LAVS;
Misc
Partial Correction
06/03/2013
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: PHASE 2 AREA;
Misc
Corrective Action Required
05/30/2013
PHASE 1 AREA CEILING ALREADY TILED; NOT READY FOR INSPECTION PHASE 2 AREA: - REMOVE CEILING TILE EXCEPT FEW ALLOWED - SECURE MC ELECT CABLE W/I 12" OF BOXES - PLUG ANY UNUSED J-BOX OPENINGS - CLOSE ALL J-BOXES - REMOVE ALL ABANDONED HANGERS, ETC
Occupancy Inspection - Codes Commercial Not Ready 6/4/2013 6/4/2013 at 12:00 AM 06/03/2013
Misc
Partial Correction
06/03/2013
TWO RESTROOMS OK FOR USE AFTER BEING APPRVOVED BY LSFD; PHASE 1 AREA HAS BEEN OCCUPIED WITHOUT INSPECTION/APPROVAL
Above Ceiling Inspection Partial 6/4/2013 6/4/2013 at 12:00 AM 06/04/2013
Misc
Partial Correction
06/03/2013
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: BOTH LAVS;
Misc
Partial Correction
06/03/2013
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: PHASE 2 AREA; PHASE 1 AREA;
Misc
Resolved
06/04/2013
PHASE 1 AREA CEILING ALREADY TILED; NOT READY FOR INSPECTION PHASE 2 AREA: - REMOVE CEILING TILE EXCEPT FEW ALLOWED - SECURE MC ELECT CABLE W/I 12" OF BOXES - PLUG ANY UNUSED J-BOX OPENINGS - CLOSE ALL J-BOXES - REMOVE ALL ABANDONED HANGERS, ETC
Occupancy Inspection - Codes Commercial Partial 6/4/2013 6/4/2013 at 12:00 AM 06/04/2013
Misc
Partial Correction
06/03/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1 (EXCEPT CASH WRAP ELECT RECEPTS YET TO BE TESTED); PHAS 2 (EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL;
Occupancy Inspection - Codes Commercial Partial 6/5/2013 at 12:00 AM 06/05/2013
Misc
Partial Correction
06/04/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1; PHASE 2 EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL;
Occupancy Inspection - Codes Commercial Partial 6/5/2013 6/5/2013 at 12:00 AM 06/05/2013
Misc
Partial Correction
06/04/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1 (EXCEPT CASH WRAP ELECT RECEPTS YET TO BE TESTED); PHAS 2 (EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL;
In-wall Inspection Partial 6/6/2013 6/6/2013 at 12:00 AM 06/06/2013
Misc
Partial Correction
05/10/2013
OK TO COVER WHEN READY WALL FRAMING + IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: DEMISING WALL AT NON-SALES EAST; BOTH LAVS BOTH FACES OF WALLS; 8" FALSE WALL BUMP-OUT AT CENTER OF JUSTICE SALES W WALL; S & W WALLS OF BROTHERS' SALES -- DIAGONAL BRACING OF TOPS OF WALLS SUBJECT TO APPROVAL WHEN COMPLETED;
Above Ceiling Inspection Passed 6/13/2013 6/13/2013 at 12:00 AM 06/13/2013
Misc
Partial Correction
06/04/2013
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: BOTH LAVS; PHASE 3 SALES AREA AFTER ONE HANGER IS ADDED ON F.P. SPRINKLER PIPING;
Misc
Partial Correction
06/04/2013
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: PHASE 2 AREA; PHASE 1 AREA;
Above Ceiling Inspection Partial 5/10/2013 at 12:00 AM 06/17/2013
Misc
Resolved
06/17/2013
OK TO COVER WHEN READY GWB CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: BOTH LAVS;
Misc
Resolved
06/17/2013
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES:
Above Ceiling Inspection Passed 6/17/2013 6/17/2013 at 12:00 AM 06/17/2013
Occupancy Inspection - Codes Commercial Partial 6/18/2013 at 12:00 AM 06/18/2013
Misc
Partial Correction
06/05/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1; PHASE 2 EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL; LIGHTED SIGN ELEMENTS UL LABELED AND OK FOR INSTALLATION;
Occupancy Inspection - Codes Commercial Partial 6/21/2013 6/21/2013 at 12:00 AM 06/21/2013
Misc
Partial Correction
06/18/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1; PHASE 2 EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL; INTERIM PHASE BETWEEN PHASE 2 AND PHASE 3 -- NOW ALL AREAS EXCEPT BROTHERS SALES AREA; LIGHTED SIGN ELEMENTS UL LABELED AND OK FOR INSTALLATION;
In-wall Inspection Passed 6/6/2013 at 12:00 AM 06/27/2013
Misc
Partial Correction
06/27/2013
OK TO COVER WHEN READY WALL FRAMING + IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: DEMISING WALL AT NON-SALES EAST; BOTH LAVS BOTH FACES OF WALLS; 8" FALSE WALL BUMP-OUT AT CENTER OF JUSTICE SALES W WALL; S & W WALLS OF BROTHERS' SALES -- DIAGONAL BRACING OF TOPS OF WALLS SUBJECT TO APPROVAL WHEN COMPLETED;
Occupancy Inspection - Codes Commercial Failed 6/27/2013 6/27/2013 at 12:00 AM 06/27/2013
Misc
Resolved
06/27/2013
FOLLOWING AREAS OK FOR USE & OCCUPANCY: TWO RESTROOMS; PHASE 1; PHASE 2 EXCEPT ELECT RECEPTS TO BE TESTED WITH PHASE 3 FINAL; INTERIM PHASE BETWEEN PHASE 2 AND PHASE 3 -- NOW ALL AREAS EXCEPT BROTHERS SALES AREA; LIGHTED SIGN ELEMENTS UL LABELED AND OK FOR INSTALLATION;
Misc
Corrective Action Required
06/27/2013
resolve fire dept issues
Occupancy Inspection - Codes Commercial Full C of O 7/1/2013 at 12:00 AM 07/01/2013
Misc
Resolved
07/01/2013
resolve fire dept issues
Alarm Test Passed 7/1/2013 at 9:00 AM 07/01/2013
Occupancy Inspection - Fire Passed 7/1/2013 at 9:00 AM 07/01/2013
Documents & Images
Date Uploaded File Type Document Name
12/07/2012 Letter Plan Review Conditions
04/29/2013 Letter Building Permit
04/29/2013 Letter Plan Review Conditions
05/07/2013 Letter Inspection Summary
05/08/2013 Letter Inspection Summary
05/10/2013 Letter Inspection Summary
06/13/2013 Letter Inspection Summary
06/17/2013 Letter Inspection Summary
06/18/2013 Letter Inspection Summary
06/21/2013 Letter Inspection Summary
06/21/2013 Letter Fire Building Plan Review
06/21/2013 Letter Fire Building Plan Review
06/21/2013 Letter Fire Building Plan Review
06/27/2013 Letter Fire (Sprinkler) Plan Review
07/01/2013 Letter Field Certificate of Occupancy
07/01/2013 Letter Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home