Summary
PRCOM20122453
Building Permit - Commercial
Certificate of Occupancy
JOHN CALVIN MANOR INC
ALTERATION COMMERCIAL
INTERIOR REMODEL
11/05/2012
12/09/2013
10/22/2013
01/15/2015
Locations
Contacts
4SIGHT GROUP LLC, Address:7920 WARD PKWY, Phone:(816) 802-8400  
JOHN CALVIN MANOR INC, Address:310 NW MURRAY  
4SIGHT GROUP LLC, Address:7920 WARD PKWY, Phone:(816) 802-8400  
PROSPERITY ELECTRIC LLC, Address:1601 E 18TH ST #205, Phone:(816) 318-6050  
LMG CONSTRUCTION, Address:3011 ROANOKE RD, Phone:(816) 474-0333  
Reviews
Review Type Outcome Est. Completion Date Completed
Alarm Plan Review Released for Construction 03/28/2014 03/25/2014
Brian Austerman
Misc
Corrective Action Required
03/25/2014

907.2 Where required—new buildings and structures. An approved manual, automatic or manual and automatic fire alarm system installed in accordance with the provisions of this code and NFPA 72 shall be provided in new buildings and structures in accordance with Sections 907.2.1 through 907.2.23 and provide occupant notification in accordance with Section 907.10, unless other requirements are provided by another section of this code. Where automatic sprinkler protection installed in accordance with Section 903.3.1.1 or 903.3.1.2 is provided and connected to the building fire alarm system, automatic heat detection required by this section shall not be required. The automatic fire detectors shall be smoke detectors. Where ambient conditions prohibit installation of automatic smoke detection, other automatic fire detection shall be allowed. Change the heat detectors to smoke detectors
Installation acceptance testing
Corrective Action Required
03/25/2014

2006 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. Call (816) 969-1300 to schedule alarm testing
Internal Plan Review (Com) Approved 12/31/2013 12/09/2013
Mike Weisenborn
True
Licensed Contractors Approved 12/31/2013 12/09/2013
Mike Weisenborn
Building Plan Review Approved 10/22/2012 12/09/2013
Mike Weisenborn
Business License
Resolved
10/25/2012

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawfull for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required - Provide the name of the licensed general contractor. A minimum of a Class B license will be required.
License contractors
Resolved
12/09/2013

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - I don't see where Allan's Electric or KC Plumbing have a current business license with the City of Lee's Summit. Current licenses will be required prior to permit issuance.
Misc
Resolved
12/09/2013

I have spoken with the building inspector for this project and he has requested that we issue separate permits for each building in the project. This will aid in inspection requests and project tracking. Action required - Please provide a separate project value for each building.
Fire Plan Review Approved with Conditions 10/22/2012 10/24/2012
Jim Eden
Address numbers required
Corrective Action Required
10/24/2012

2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Maintain addressing on the buildings and numbering of the apartments on the interior doors and exterior doors of apartments on grade. Verified at inspection.
Construction documents for fire alarm systems
Corrective Action Required
10/24/2012

2006 IFC 907.1.1- Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: 1. .A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions. Provide plans and specifications for ugrades and alaterations to the alarm system.
Misc
Corrective Action Required
10/24/2012

1411.2 Maintenance. Required means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Alteration to Commercial $554.72 $554.72 Paid 12/09/2013
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Partial 7/25/2014 at 12:00 AM 07/25/2014
Partial Correction
07/25/2014
OK TO COVER WHEN READY FRAMING & ELECTRICAL WORK AT REPLACED AWNING @ N ENTRANCE
All Rough Inspection - Commercial Partial 8/14/2014 8/14/2014 at 12:00 AM 08/14/2014
Misc
Partial Correction
08/14/2014
OK TO COVER WHEN READY EXPOSED WALL AND CEILING CAVITIES ALONG WITH SYSTEMS TO BE CONCEALED AT FOLLOWING SPACES: 107-114;
All Rough Inspection - Commercial Partial 8/18/2014 8/18/2014 at 12:00 AM 08/18/2014
Misc
Resolved
08/18/2014
OK TO COVER WHEN READY EXPOSED WALL AND CEILING CAVITIES ALONG WITH SYSTEMS TO BE CONCEALED AT FOLLOWING SPACES: 107-114; 101-106
Misc
Corrective Action Required
08/18/2014
SYSTEMS IN CRAWL SPACE SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Corrective Action Required
08/18/2014
SYSTEMS IN ATTIC SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
All Rough Inspection - Commercial Partial 8/22/2014 8/22/2014 at 12:00 AM 08/22/2014
Misc
Partial Correction
08/22/2014
SYSTEMS IN CRAWL SPACE SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Partial Correction
08/22/2014
SYSTEMS IN ATTIC SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Partial Correction
08/22/2014
OK TO COVER WHEN READY EXPOSED WALL AND CEILING CAVITIES ALONG WITH SYSTEMS TO BE CONCEALED AT FOLLOWING SPACES: 107-114; 101-106; 100 AFTER a) GAPS AT TOPS OF JACK STUDS AT EXTERIOR WALL ARE SHIMMED AND b) SLOPE OF HORIZONTAL PLUMBING VENT ARM IS REVERSED TO DRAIN;
Underground Electrical Inspection - Commercial Passed 9/4/2014 at 12:00 AM 09/04/2014
All Rough Inspection - Commercial Not Ready 9/11/2014 at 12:00 AM 09/11/2014
Misc
Partial Correction
08/22/2014
SYSTEMS IN CRAWL SPACE SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Partial Correction
08/22/2014
SYSTEMS IN ATTIC SUBJECT TO APPROVAL WHEN READY FOR INSPECTION. FOUND TO BE NOT READY 9/11/14.
Footing Inspection - Commercial Passed 9/12/2014 (10:45) 9/12/2014 at 12:00 AM 09/12/2014
All Rough Inspection - Commercial Partial 9/16/2014 9/16/2014 at 12:00 AM 09/16/2014
Misc
Partial Correction
09/11/2014
SYSTEMS IN CRAWL SPACE SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Partial Correction
09/11/2014
SYSTEMS IN ATTIC OK EXCEPT OPEN ELECT J.BOXES NEAR NORTH END. INTEGRITY OF DRAFT WALLS YET TO BE IMPROVED. ALL SUBJECT TO APPROVAL AT FINAL INSPECTION.
Occupancy Inspection - Fire Temporary C of O 9/24/2014 at 12:00 AM 09/24/2014
Misc
Corrective Action Required
09/24/2014
- post the numeric address of 310 on the front of the building -replace the discharged extingusiher in the north end of corridor
Occupancy Inspection - Codes Commercial Partial 9/24/2014 9/24/2014 at 12:00 AM 09/24/2014
Misc
Partial Correction
09/24/2014
OCCUPANCY STATUS: N-S WING UNITS 101-114 + UNIT 100 OK FOR OCCUPANCY OTHER AREAS IN E-W WING SUBJECT TO APPROVAL WHEN READY. EXTERIOR WORK IN PROGRESS SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
All Rough Inspection - Commercial Partial 11/17/2014 at 12:00 AM 11/17/2014
Misc
Resolved
09/24/2014
SYSTEMS IN CRAWL SPACE SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Misc
Resolved
09/24/2014
SYSTEMS IN ATTIC OK EXCEPT OPEN ELECT J.BOXES NEAR NORTH END. INTEGRITY OF DRAFT WALLS YET TO BE IMPROVED. ALL SUBJECT TO APPROVAL AT FINAL INSPECTION.
Misc
Partial Correction
11/17/2014
OK TO COVER WHEN READY IN-WALL SYSTEMS AT NEW ACCESSIBLE RESTROOM AFTER: 1) OPENINGS ARE FIRE-BLOCKED AT TOP AND BOTTOM OF WALLS 2) COPPER PIPING IS PROTECTED WITH SHIELD/ BOCA PLATES WHEREVER LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE WALL COVERINGS.
All Rough Inspection - Commercial Partial 12/4/2014 12/4/2014 at 12:00 AM 12/04/2014
Misc
Partial Correction
11/17/2014
OK TO COVER WHEN READY IN-WALL SYSTEMS AT KITCHEN
Occupancy Inspection - Codes Commercial Partial 12/8/2014 12/8/2014 at 12:00 AM 12/08/2014
Misc
Partial Correction
09/24/2014
OCCUPANCY STATUS: N-S WING UNITS 101-114 + UNIT 100 OK FOR OCCUPANCY OTHER AREAS IN E-W WING SUBJECT TO APPROVAL WHEN READY. EXTERIOR WORK IN PROGRESS SUBJECT TO APPROVAL WHEN READY FOR INSPECTION.
Occupancy Inspection - Codes Commercial Partial 1/5/2015 1/5/2015 at 12:00 AM 01/05/2015
Misc
Partial Correction
12/08/2014
OK FOR OCCUPANCY: N-S WING UNITS 101-114; UNIT 100;
Misc
Corrective Action Required
01/05/2015
KITCHEN: 1) ELECT RECEPT LEFT OF SINK HAS APPARENT OPEN GROUND -- GFCI DOES NOT TRIP 2) LECT RECEPT ABOVE WALL CABINETS HAS APPARENT OPEN GROUND 3) CHECK ALL RECEPTS (INCLUDING ONE UNDER SINK) & INSTALL SPACERS BEHIND YOKES; SCREW YOKES SOLID
Misc
Corrective Action Required
01/05/2015
ACCESSIBLE RESTROOM: INSTALL 18" VERTICAL GRAB BAR PER DRAWING & ANSI
Occupancy Inspection - Fire Passed 1/5/2015 at 12:00 AM 01/09/2015
Misc
Corrective Action Required
01/09/2015
- post the numeric address of 310 on the front of the building -replace the discharged extingusiher in the north end of corridor
Occupancy Inspection - Codes Commercial Partial 1/12/2015 1/12/2015 at 12:00 AM 01/12/2015
Misc
Partial Correction
01/05/2015
OK FOR OCCUPANCY: N-S WING UNITS 101-114; UNIT 100;
Misc
Corrective Action Required
01/05/2015
KITCHEN: 1) FOUR-PLEX ELECT RECEPT LEFT OF REFRIGERATOR NOT GFI-PROTECTED.
Misc
Resolved
01/12/2015
ACCESSIBLE RESTROOM: INSTALL 18" VERTICAL GRAB BAR PER DRAWING & ANSI
All Rough Inspection - Commercial Passed 12/4/2014 at 12:00 AM 01/14/2015
Misc
Resolved
01/14/2015
OK TO COVER WHEN READY IN-WALL SYSTEMS AT KITCHEN
Occupancy Inspection - Codes Commercial Full C of O 1/14/2015 1/15/2015 at 12:00 AM 01/15/2015
Misc
Resolved
01/15/2015
OK FOR OCCUPANCY: N-S WING UNITS 101-114; UNIT 100;
Misc
Resolved
01/14/2015
Documents & Images
Date Uploaded File Type Document Name
05/02/2013 PRCOM20122246prext.pdf
12/09/2013 Letter Codes Plan Review Conditions
12/09/2013 Letter Codes Building Permit
03/25/2014 Letter Fire (Alarm) Plan Review Notice
07/25/2014 Letter Inspection Summary
08/06/2014 Letter DOC080614
08/14/2014 Letter Inspection Summary
08/18/2014 Letter Inspection Summary
08/22/2014 Letter Inspection Summary
09/04/2014 Letter Inspection Summary
09/12/2014 Letter Inspection Summary
09/16/2014 Letter Inspection Summary
09/24/2014 Letter Inspection Summary
11/17/2014 Letter Inspection Summary
12/04/2014 Letter Inspection Summary
12/08/2014 Letter Inspection Summary
01/05/2015 Letter Inspection Summary
01/12/2015 Letter Inspection Summary
01/15/2015 Letter Field Certificate of Occupancy
01/23/2015 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home