Summary
PRCOM20121791
Building Permit - Commercial
Certificate of Occupancy
ALBERTS REALTY INC
CHANGE OF TENANT
TENANT FINISH FOR A SALON. PREVIOUS TENANT WAS RETAIL LOCKBOX CODE: 0306
08/09/2012
08/24/2012
02/17/2013
10/08/2012
Locations
Contacts
WOOLERY CONSTRUCTION, Address:7005 GLADSTONE, Phone:(913) 631-7523  
B & C MECHANICAL SERVICES LLC, Address:2008 E SPRUCE CIR STE B, Phone:(913) 681-0088  
O'CONNELL ELECTRIC LLC, Address:11017 S ALLEY JACKSON RD, Phone:(816) 547-4706  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
GUY GRONBERG ARCHITECTS, Address:113 SE 3RD ST, Phone:(816) 524-0878  
ALBERTS REALTY INC, Address:37809 E US HIGHWAY 50  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/31/2012 08/24/2012
Codes Admin
True
License Tax Codes Approved 08/31/2012 08/22/2012
Codes Admin
Building Plan Review Approved 08/21/2012 08/21/2012
Mike Weisenborn
License contractors
Corrective Action Required
08/21/2012

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - Provide the names of the licensed contractors prior to permit approval.
Accessibility - Water closet - Grab bars
Corrective Action Required
08/21/2012

ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - Grab bars shall be installed if not existing. To be verified on inspection.
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
08/21/2012

2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - This comment is for information purposes. To be verified on inspection.
Misc
Corrective Action Required
08/21/2012

The plans provided do not indicate that any type of nail stations in this space. Manicure/pedicures are not approved activities in this space. Action required - No action required.
Bldg - Accessibility - Toilet and bathing facilities
Carried Forward
08/21/2012

2006 IBC 1109.2 - Toilet and bathing facilities. Toilet rooms and bathing facilities shall be accessible. Where a floor level is not required to be connected by an accessible route, the only toilet rooms or bathing facilities provided within the facility shall not be located on the inaccessible floor. At least one of each type of fixture, element, control or dispenser in each accessible toilet room and bathing facility shall be accessible. Action required - The existing restrooms in this space do not meet the current regulations for accessibility. As the entrance to the space does not meet the requirements for accessibility, the restrooms will not be required to be fully accessible at this time. As the space is accessible to individuals with special needs other than the use of a wheelchair, the restrooms shall be made as compliant as possible. This comment is for information purposes.
Plumb - Backflow general 608.3
Corrective Action Required
08/21/2012

2006 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softeners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination. Action required - A backpressure or backsiphonage device shall be provided on the shampoo station sprayers. This will be verified on inspection.
Internal Plan Review (Res) Rejected 08/21/2012 08/21/2012
Mike Weisenborn
Fire Plan Review Approved 08/21/2012 08/13/2012
Jim Eden
Portable fire extinguishers - conspicuous locations
Corrective Action Required
08/13/2012

2006 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Provide a fire extinguisher near the front door. Verified at inspection.
Zoning Review Approved 08/21/2012 08/09/2012
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Change of Tenant $30.00 $30.00 Paid 08/24/2012
8331507-Sewer Connection Fee $90.00 $90.00 Paid 08/24/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Not Ready 8/28/2012 at 12:00 AM 08/28/2012
Misc
Corrective Action Required
08/28/2012
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT DRAWINGS.
Rough Plumbing Inspection - Commercial Not Ready 8/28/2012 8/28/2012 at 12:00 AM 08/28/2012
Misc
Corrective Action Required
08/28/2012
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT DRAWINGS.
Underslab Plumbing Inspection - Commercial Passed 8/29/2012 8/29/2012 at 12:00 AM 08/29/2012
Misc
Resolved
08/29/2012
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT DRAWINGS.
Rough Electrical Inspection - Commercial Not Ready 9/11/2012 (8:00 to 5:00) 9/11/2012 at 12:00 AM 09/11/2012
Misc
Corrective Action Required
09/11/2012
BUILDING LOCKED; NO ACCESS
Rough Electrical Inspection - Commercial Passed 9/14/2012 at 12:00 AM 09/14/2012
Misc
Resolved
09/14/2012
BUILDING LOCKED; NO ACCESS
Rough Framing Inspection - Commercial Passed 9/14/2012 at 12:00 AM 09/14/2012
Rough Mechanical Inspection - Commercial Failed 10/1/2012 at 12:00 AM 10/01/2012
Misc
Corrective Action Required
10/01/2012
1. FLUE CLEARANCE TO COMUSTIBLES- WOOD ELECTRICAL ETC. 2. MULTIPLE FLUE CONNECTOR PIPE(WYE) shall be dbl wall . 3. PROVIDE GAS PRESSURE TEST. 4. SUPPORT WARDFLEX PER CODE TO WATER HEATERS. 5. EXTEND FLUE AT ROOF TOP TO CORRECT HEIGHT ABOVE ROOF. 6. POS COUNTER SHALL MEET ADA & ANSI 117
Rough Mechanical Inspection - Commercial Passed 10/3/2012 10/3/2012 at 12:00 AM 10/03/2012
Misc
Resolved
10/03/2012
1. FLUE CLEARANCE TO COMUSTIBLES- WOOD ELECTRICAL ETC. 2. MULTIPLE FLUE CONNECTOR PIPE(WYE) shall be dbl wall . 3. PROVIDE GAS PRESSURE TEST. 4. SUPPORT WARDFLEX PER CODE TO WATER HEATERS. 5. EXTEND FLUE AT ROOF TOP TO CORRECT HEIGHT ABOVE ROOF. 6. POS COUNTER SHALL MEET ADA & ANSI 117
Occupancy Inspection - Fire Temporary C of O 10/5/2012 at 12:00 AM 10/05/2012
Misc
Corrective Action Required
10/05/2012
open j-box at the ceiling above the elec. panel (storage room) no combustible storage under the staircase ( storage room)
Rough Plumbing Inspection - Commercial Passed 10/05/2012
Misc
Resolved
09/14/2012
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. NO INSPECTIONS WITHOUT CITY-STAMPED PERMIT DRAWINGS.
Occupancy Inspection - Codes Commercial Temporary C of O 10/5/2012 10/5/2012 at 12:00 AM 10/05/2012
Occupancy Inspection - Fire Passed 10/8/2012 at 12:00 AM 10/08/2012
Misc
Corrective Action Required
10/08/2012
open j-box at the ceiling above the elec. panel (storage room) no combustible storage under the staircase ( storage room)
Misc
Corrective Action Required
10/08/2012
ALL PREVOUS ISSUES HAVE BEEN RESOLVED
Occupancy Inspection - Codes Commercial Full C of O 10/8/2012 at 12:00 AM 10/08/2012
Documents & Images
Date Uploaded File Type Document Name
08/21/2012 Letter Plan Review Conditions
08/24/2012 Letter Building Permit
08/28/2012 Letter Inspection Summary
08/29/2012 Letter Inspection Summary
09/14/2012 Letter Inspection Summary
10/01/2012 Letter Inspection Summary
10/03/2012 Letter Inspection Summary
10/05/2012 Letter Fire Loss Reduction Form
10/05/2012 Letter Temporary Certificate of Occupancy
10/08/2012 Letter Fire Loss Reduction Form
10/08/2012 Letter Field Certificate of Occupancy
10/09/2012 Letter Final Certificate of Occupancy
06/25/2013 Letter Fire Building Plan Review
06/27/2013 Letter Plan Review Conditions
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home