Permit Application Status

PRCOM20120446


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20120446
Building Permit - Commercial
Certificate of Occupancy
CBL LEES SUMMIT EAST LLC
NEW TENANT FINISH
ESTABLISH OCCUPANCY
03/15/2012
06/07/2012
06/21/2012
Locations
Contacts
CBL LEES SUMMIT EAST LLC, Address:2030 HAMILTON PLACE BLVD STE 500  
SPORTZ NUTZ, Address:910 NW BLUE PKWY, UNIT R  
RED SUMMIT FAIR LLC, Address:1 E WASHINGTON ST STE 300  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/27/2012 03/15/2012
Mike Weisenborn
True
Fire Plan Review Approved 03/16/2012 03/15/2012
Brian Austerman
Portable fire extinguishers - conspicuous locations
Corrective Action Required
03/15/2012

2006 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Action Required: Provide one 2A10B:C extinguisher for every 75' of travel distance. Verified at inspection
IFGC - Inspection, testing and maintenance - alarm and extinguishing systems 901.6
Corrective Action Required
03/15/2012

2006 IFC 901.6- Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Not required fire protection systems and equipment shall be inspected, tested and maintained or removed. Action Required: Do not place shelving or stock in a way that will obsucre or impare alarm notification devices. Verified at inspection
Misc
Corrective Action Required
03/15/2012

2305.4 Aisle maintenance. When restocking is not being conducted, aisles shall be kept clear of storage, waste material and debris. Fire department access doors, aisles and exit doors shall not be obstructed. During restocking operations using manual stocking methods, a minimum unobstructed aisle width of 24 inches (610 mm) shall be maintained in 48-inch (1219 mm) or smaller aisles, and a minimum unobstructed aisle width of one-half of the required aisle width shall be maintained in aisles greater than 48 inches (1219 mm). During mechanical stocking operations, a minimum unobstructed aisle width of 44 inches (1118 mm) shall be maintained in accordance with Section 2306.9. Action Required: For information only
License Tax Codes Approved 03/27/2012 03/15/2012
Mike Weisenborn
Building Plan Review Approved 03/16/2012 03/15/2012
Mike Weisenborn
Misc
Corrective Action Required
03/15/2012

This permit is to establish the occupancy type for the space as it was not previously occupied. Any items found on inspection shall be corrected and scheduled for a reinspection.
Zoning Review Approved 03/27/2012 03/15/2012
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $30.00 $30.00 Paid 06/07/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sprinkler - Flow Test Passed 10/14/2011 at 12:00 AM 06/07/2012
Alarm Test Passed 10/14/2011 at 12:00 AM 06/07/2012
Occupancy Inspection - Codes Commercial Temporary C of O 6/11/2012 6/11/2012 at 12:00 AM 06/11/2012
Misc
Corrective Action Required
06/11/2012
IBC 1210.1: SURFACE OF RESTROOM FLOOR / WALL SURFACE TO 48" A.F.F WITHIN 24" OF WATER CLOSET OR URINAL AND TO 6" A.F.F. PERIMETER OF ROOM. MUST BE NON-ABSORBENT, SMOOTH.
Occupancy Inspection - Fire Passed 6/11/2012 at 12:00 AM 06/11/2012
Misc
Corrective Action Required
06/11/2012
appeared OK at the time of the inspection, OK to occupy once cleared through codes administration
Occupancy Inspection - Codes Commercial Full C of O 6/21/2012 6/21/2012 at 12:00 AM 06/21/2012
Misc
Resolved
06/21/2012
IBC 1210.1: SURFACE OF RESTROOM FLOOR / WALL SURFACE TO 48" A.F.F WITHIN 24" OF WATER CLOSET OR URINAL AND TO 6" A.F.F. PERIMETER OF ROOM. MUST BE NON-ABSORBENT, SMOOTH.
Documents & Images
Date Uploaded File Type Document Name
06/07/2012 Letter Plan Review Conditions
06/07/2012 Letter Building Permit
06/11/2012 Letter Temporary Certificate of Occupancy
06/11/2012 Letter Fire Loss Reduction Form
06/21/2012 Letter Field Certificate of Occupancy
06/22/2012 Letter Final Certificate of Occupancy
06/25/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home