Permit Application Status

PRCOM20120156


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20120156
Building Permit - Commercial
Final Completion
DOUGLAS STATION SHOPPING CENTER LLC
CHANGE OF TENANT
CHANGE OF TENANT, KITCHEN AND RESTROOMS EXISTING
01/30/2012
02/07/2012
03/05/2012
Locations
Contacts
DOUGLAS STATION SHOPPING CENTER LLC, Address:1725 NE RICE RD  
LUTFI'S FISH AND CHICKEN, Address:1196 NE DOUGLAS ST  
LS INVESTORS ONE LLC, Address:1220 WASHINGTON ST PO BOX 411299  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 02/09/2012 02/07/2012
Mike Weisenborn
True
License Tax Codes Approved 02/09/2012 02/07/2012
Mike Weisenborn
Fire Plan Review Approved 02/09/2012 02/06/2012
Jim Eden
Posting of occupant load
Corrective Action Required
02/06/2012

2006 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Verified at inspection.
IFGC - Inspection, testing and maintenance - alarm and extinguishing systems 901.6
Corrective Action Required
02/06/2012

2006 IFC 901.6- Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Not required fire protection systems and equipment shall be inspected, tested and maintained or removed. The hood suppression system shall have a current 67 month inspection tag and nozzles shall be adjusted or added to meet the requirements of the new appliances. Verified at inspection.
Portable fire extinguishers for commercial cooking equipment.
Corrective Action Required
02/06/2012

2006 IFC 904.11.5- Portable fire extinguishers for commercial cooking equipment. Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. Provide under the manual pull station for the hood suppression system. Verified at inspection.
Portable fire extinguishers - general
Corrective Action Required
02/06/2012

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one 2A:10BCfire extinguisher at a conspicuous location. Verified at inspection.
Building Plan Review Approved 02/09/2012 01/30/2012
Mike Weisenborn
Health Dept Inspection
Corrective Action Required
02/02/2012

For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Health Division at 816-881-4455. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required - This comment is for information purposes.
Bldg - Toilet rooms - Floor surface and walls
Resolved
02/02/2012

2006 IBC 1210.1 - Floors. In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbent surface that extends upward onto the walls at least 6 inches. Action required - The 4 inch base will be allowed as it is allowed in the 2009 and 2012 IBC.
Bldg - Toilet rooms - Walls
Corrective Action Required
02/02/2012

2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture. Action required - To be verified on inspection.
Zoning Review Approved 02/09/2012 01/30/2012
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $30.00 $30.00 Paid 02/07/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Fire Passed 02/28/2012
Occupancy Inspection - Codes Commercial Failed 02/28/2012
Misc
Corrective Action Required
02/28/2012
NEC: COMPLETE ELECTRICAL PANEL SCHEDULE; PRINT LEGIBLE AND AFFIX TO INSIDE OF PANEL DOOR
Misc
Corrective Action Required
02/28/2012
IPC: VENTING REQUIRED AT TWO-COMPARTMENT SINK @ CENTER OF KITCHEN
Misc
Corrective Action Required
02/28/2012
IPC: VENTING OF THREE-COMPARTMENT SINK @ KITCHEN NORTH MUST EXTEND TO ATMOSPHERE
Misc
Corrective Action Required
02/28/2012
IPC: DRAIN AT SINK IN SERVING AREA: 1) NO TRAP 2) INDIRECT DRAIN NOT APPROVED
Misc
Corrective Action Required
02/28/2012
IPC 608: BACKFLOW PREVENTION DEVICE REQUIRED AT ICE MAKER WATER FEED LINE
Final Inspection - Commercial Passed 3/2/2012 at 12:00 AM 03/02/2012
Documents & Images
Date Uploaded File Type Document Name
02/07/2012 Letter Building Permit
02/07/2012 Letter Plan Review Conditions
02/28/2012 Letter Fire Loss Reduction Form
02/28/2012 Letter Inspection Summary
03/02/2012 Letter Inspection Summary
06/25/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home