Summary
PRCOM20116302
Building Permit - Commercial
Final Completion
TLS MARKET PLACE LLC
REPAIR REPLACE UPGRADE
REPAIR EXISTING METAL CATWALK *drawings are in permit file
12/13/2011
12/13/2011
07/16/2012
Locations
Contacts
STUCKER CONSTRUCTION INC, Address:1120 NW EAGLE RIDGE BLVD, Phone:(816) 795-1317  
TLS MARKET PLACE LLC, Address:P O BOX 3994  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 12/13/2011
Codes Admin
True
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Repair/Replace/Upgrade $68.41 $68.41 Paid 12/13/2011
$0.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Passed 4/3/2012 at 12:00 AM 04/03/2012
Above Ceiling Inspection Partial 5/8/2012 at 12:00 AM 05/08/2012
Misc
Partial Correction
05/08/2012
NO ISSUES FOUND ON CATWALK FRAMING. DO NOT INSTALL SOFFIT BEFORE ALL WORK ABOVE IS COMPLETED, INSPECTED AND APPROVED.
Above Ceiling Inspection Passed 5/11/2012 at 12:00 AM 05/11/2012
Misc
Resolved
05/11/2012
NO ISSUES FOUND ON CATWALK FRAMING. DO NOT INSTALL SOFFIT BEFORE ALL WORK ABOVE IS COMPLETED, INSPECTED AND APPROVED.
Final Inspection - Commercial Failed 6/28/2012 at 12:00 AM 06/28/2012
Misc
Corrective Action Required
06/28/2012
COLUMN PIERS ARE HEAVILY HONEYCOMBED. PER 6/28/12 TELECON W/ LARRY STUCKER, HE WILL HAVE THEM FILLED & RUBBED.
Final Inspection - Commercial Failed 7/12/2012 at 12:00 AM 07/12/2012
Misc
Corrective Action Required
06/28/2012
COLUMN PIERS ARE HEAVILY HONEYCOMBED. PER 6/28/12 TELECON W/ LARRY STUCKER, HE WILL HAVE THEM FILLED & RUBBED.
Final Inspection - Commercial Passed 7/16/2012 at 12:00 AM 07/16/2012
Misc
Resolved
07/16/2012
COLUMN PIERS ARE HEAVILY HONEYCOMBED. PER 6/28/12 TELECON W/ LARRY STUCKER, HE WILL HAVE THEM FILLED & RUBBED.
Documents & Images
Date Uploaded File Type Document Name
12/13/2011 Letter Building Permit
12/13/2011 Activity Document 20111213163644559.pdf
04/03/2012 Letter Inspection Summary
05/08/2012 Letter Inspection Summary
05/11/2012 Letter Inspection Summary
07/12/2012 Letter Inspection Summary
07/16/2012 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home