Summary
PRCOM20110319
Building Permit - Commercial
Final Completion
ALTERATION COMMERCIAL
Chemistry classroom remodel
03/11/2011
04/07/2011
08/19/2011
Locations
Contacts
The Clark Emersen Partners, Address:1251 NW Briarcliff Pkwy  
EDWARDS MCDOWELL INC, Address:400 E 10TH AVE, Phone:(816) 221-7878  
BRINTON ELECTRIC COMPANY INC, Address:10100 E 65TH ST STE B, Phone:(816) 356-0922  
CORLESS MECHANICAL INC, Address:26020 S SKYLINE DR, Phone:(816) 380-4448  
KC METROPOLITAN COMMUNITY, Address:3200 BROADWAY  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/23/2011 03/23/2011
Mike Weisenborn
Fire Plan Review Approved 03/23/2011 03/22/2011
Jim Eden
Building Plan Review Approved 03/23/2011 03/22/2011
Mike Weisenborn
Bldg - Occupant load calculations - Areas without fixed seats
Resolved
03/22/2011

2006 IBC 1004.1.1 - Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.1.1. For areas with out fixed seating, the occupant load shall not be less than that number determined by dividing the floor area under consideration by the occupant per unit of area factor assigned to the occupancy as set forth in Table 1004.1.1. Where an intended use is not listed in Table 1004.1.1, the building official shall establish a use based on a listed use that most nearly resembles the intended use. The code requirements on SHeet G0.2 calculates the occupant load of the classrooms at 1:20. Table 1004.1.1 also has "Shops and other vocational room areas" which is calculated at 1:50. This multiplier better suits the use of the space and is more in line with the number of work stations shown. The review is based on an occupant load of 20 in the lab.
License Tax Codes Approved 03/23/2011 03/21/2011
Mike Weisenborn
Historical Preservation Review Approved 03/23/2011 03/14/2011
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $1,594.29 $1,594.29 Paid 04/07/2011
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 6/16/2011 at 12:00 AM 06/16/2011
Above Ceiling Inspection Failed 7/21/2011 at 12:00 AM 07/21/2011
Misc
Corrective Action Required
07/21/2011
ROOM 203: FLEX DUCT CONNECTORS ARE TO BE TAPED AND CONNECTED PER FLEX DUCT MANUFACTURERS INSTRUCTIONS AT CONNECTIONS TO MAIN TRUNK.
Above Ceiling Inspection Passed 7/27/2011 at 12:00 AM 07/27/2011
Misc
Resolved
07/27/2011
ROOM 203: FLEX DUCT CONNECTORS ARE TO BE TAPED AND CONNECTED PER FLEX DUCT MANUFACTURERS INSTRUCTIONS AT CONNECTIONS TO MAIN TRUNK.
Gas Piping Inspection - Commercial Passed 8/18/2011 at 12:00 AM 08/18/2011
Final Inspection - Commercial Passed 8/18/2011 at 12:00 AM 08/18/2011
Documents & Images
Date Uploaded File Type Document Name
04/07/2011 Letter Plan Review Conditions
04/07/2011 Ordinance Building Permit
06/16/2011 Letter Inspection Summary
07/21/2011 Letter Inspection Summary
07/27/2011 Letter Inspection Summary
08/18/2011 Letter Inspection Summary
07/02/2013 Letter Fire Building Plan Review
08/27/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home