Permit Application Status

B9802036


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B9802036
Building Permit - Commercial
Certificate of Occupancy
SOUTHSIDE PLAZA LLC
ALTERATION COMMERCIAL
ALTER TENANT SPACE
12/21/1998
12/23/1998
06/21/1999
02/12/1999
Locations
Contacts
THE STAMP PATCH, Address:856 SW BLUE PARKWAY  
SOUTHSIDE PLAZA LLC, Address:215 W 77TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/19/1999 10/29/2010
Correction

Codes Administration- All signage that provides emergency information or general circulation directions or identifies rooms and spaces shall comply with 4.28.2, 4.28.3, and 4.28.5. Tactile signage shall also comply with 4.28.4. ANSI A117.7-1986 Section 4.28.1
Correction

Codes Administration- No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

Codes Administration- In public areas of Group B, Division 2 Occupancies, and in assembly occupancies without fixed seats, the minimum clear aisle width shall be 36 inches where tables, counters, furnishings, merchandise or other similar obstructions are placed on one side of the aisle only and 44 inches when such obstructions are placed on both sides of the aisle. 1991 UBC Section 3315.b.2
Correction

Portable fire extinguishers shall be installed in occupancies and locations as set forth in the Uniform Fire Code Standards and as required by the Cheif. Extinguishers shall be mounted in a conspicuous place with travel distance between any point in the building and an extinguisher not to exceed 75 feet. Extinguishers shall be aminimum of 2A-10BC (5 lb). UFC 10.505.a
Correction

Any exterior doors not to be used as exits shall have the exit signage removed.
Correction

An occupancy inspection shall be performed by the City of Lee's Summit prior to opening the business. To schedule the inspection please call the Building Inspections Division at 969-7308 a minimum of one day in advance.
Correction

The plan review for this project was based upon the sketch that was provided to us. Additional requirements may be addressed at the time inspection.
Correction

Fire Department- Approved numbers or address shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Said numbers shall contrast with their background. (UFC Section 10.301.(a))
Correction

Fire Department- Extension cords shall not be utilized as a substitute for permanent wiring. Extension cords shall only be utilized with portable appliances while such appliances are in use and shall only supply one portable appliance except for approved multi-plug extension cords. Extension cords shall be grounded when serving grounded appliances. Extension cords and multi-plug extension cords shall not be affixed to structures; extened through walls, ceilings, floors, under doors or floor coverings; or be subject to environmental or physical damage. (UFC Section 85.106.(a), (b) and (c))
Fees
Paid Fees Amount Paid Owing Date Paid
24 BLDG Permit Fees $8.00 $8.00 Paid 12/23/1998
24 BLDG Plan Check Fees $2.50 $2.50 Paid 12/23/1998
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections

There are no inspections for this permit application.

Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home