Permit Application Status

B1001257


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1001257
Building Permit - Commercial
Certificate of Occupancy
Alliance Petroleum LLC
NEW COMMERCIAL
NEW CONVIENCE STORE WITH ATTACHED SINGLE BAY CAR WASH AND DETACHED FUELING CANOPY.
10/11/2010
05/12/2011
09/20/2011
03/23/2012
Locations
Contacts
OSM INC, Address:1550 OLIVE BLVD SUITE 207  
BRACKNEY CONSTRUCTION AND SUPPLY INC, Address:305 E 21ST ST, Phone:(785) 625-4040  
PORTER ELECTRICAL, Address:114 VETERANS PKWY, Phone:(816) 540-3271  
MIKE COX PLUMBING INC, Address:PO BOX 650, Phone:(816) 773-0749  
MYERS FURNACE COMPANY, Address:534 N SCOTT AVE, Phone:(816) 331-8282  
FATBOY ELECTRIC INC, Address:P O BOX 300198, Phone:(816) 861-6600  
Alliance Petroleum LLC, Address:4251 Lindell Blvd  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved 04/13/2011 04/15/2011
Mike Weisenborn
Misc
Partial Correction
04/07/2011

Fire Department- Submit a Hazardous Materials Permit Application for review and approval. Incl;ude in the application Material Safety Data Sheets for the fuel products being stored and there quantities; tank, pump an piping specifications, detailed layout of the tank piping and appurtenances. Provide tank specifications.
Misc
Resolved
04/11/2011

Fire Department- 2006 IFC 2205.6 Warning signs. Warning signs shall be conspicuously posted within sight of each dispenser in the fuel-dispensing area and shall state the following: 1. No smoking. 2. Shut off motor. 3. Discharge your static electricity before fueling by touching a metal surface away from the nozzle. 4. To prevent static charge, do not reenter your vehicle while gasoline is pumping. 5. If a fire starts, do not remove nozzle—back away immediately. 6. It is unlawful and dangerous to dispense gasoline into unapproved containers. 7. No filling of portable containers in or on a motor vehicle. Place container on ground before filling. Action required - Provide signage.
Misc
Corrective Action Required
04/07/2011

Fire Department- 2006 IFC 2205.5 Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill-pipe openings. Action required - Show location of extinguisher. Verified at inspection.
Portable fire extinguishers - general
Corrective Action Required
04/07/2011

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required - Show location on the plans.
Misc
Corrective Action Required
04/07/2011

Fire Department- 2006 IFC 1008.1.8.3 Locks and latches. The use of a double keyed deadbolt is no permitted. Action required - Deadbolt locks shall have a thumb latch.
Misc
Corrective Action Required
04/07/2011

Fire Department- 2006 IFC 2201.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor fuel-dispensing facilities and repair garages shall be in accordance with this chapter and the International Building Code, International Fuel Gas Code and the International Mechanical Code. Such operations shall include both operations that are accessible to the public and private operations. Action required - For information only.
Misc
Corrective Action Required
04/07/2011

2203.2 Emergency disconnect switches. An approved, clearly identified and readily accessible emergency disconnect switch shall be provided at an approved location, to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. An emergency disconnect switch for exterior fuel dispensers shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel-dispensing operations, the emergency disconnect switch shall be installed at an approved location. Such devices shall be distinctly labeled as: EMERGENCY FUEL SHUTOFF. Signs shall be provided in approved locations. Action required: Show the location of the fuel shur-off.
Building Plan Review Approved 04/13/2011 04/15/2011
Mike Weisenborn
Misc
Resolved
04/15/2011

Codes Administration - Plans for the canopy have not been provided. Action required - Provide plans for the canopy. Information shall include archictectural and structural. The acrchitectural elevations have been provided but the structural have not. Provide the structural plans for the canopy. Mike Weisenborn April 11, 2011. Structural calculations have been provided but we still have not received any structural plans showing how it is to be constructed. Provide additional information. Mike Weisenborn April 15, 2011 Information has been provided.
Misc
Corrective Action Required
04/07/2011

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy. Action required - This comment is for information purposes.
Misc
Resolved
04/15/2011

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit. Action required - Provide documentation of approval from the Health Department. I have not yet received approval from the health department. Mike Weisenborn April 15, 2011 - Received approval
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
04/07/2011

Codes Administration - 2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - Show how this requirement will be met. A note has been added to Sheet A1.1. Will verify on inspection.
Misc
Resolved
04/11/2011

Codes Administration - Information on the car wash equipment has not been provided. Action required - Provide additional information. Details for the equipment to be installed shall be provided for review and approval prior to installation.
Bldg - Toilet rooms - Walls
Corrective Action Required
04/07/2011

Codes Administration - 2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture. Action required - If paint is to be used in this space it must be an epoxy paint. Make needed corrections. I believe the restroom walls are to be frp. This will be verified on inspection.
Misc
Resolved
04/11/2011

Codes Administration - A waste and vent riser diagram has not been provided. Action required - Provide additional information. The resubmittal did not include this information.
Misc
Resolved
04/11/2011

Codes Administration - A fixturing plan is not provided. Action required - Provide a fixturing plan. A complete review can not be completed until we know what equipment will be installed. The resubmittal did not include this information. Provide additional information.
Misc
Resolved
04/11/2011

Codes Administration - The plumbing plans are incomplete. The fixture schedule does not include all the fixtures and the water plan does not show water running to the mop sink. Action required - Make these corrections and any others as needed. The resbumittal did not include this information. Provide additional information.
Mech - Outdoor air required
Resolved
04/11/2011

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - Provide outdoor air calculations. The resubmital did not include this information. Provide additional information.
Plumb - Backflow general 608.3
Corrective Action Required
04/11/2011

2006 IPC 608.3 - Devices, appurtenances, appliances and apparatus. All devices, appurtenances, appliances and apparatus intended to serve some special function, such as sterilization, distillation, processing, cooling, or storage of ice or foods, and that connect to the water supply system, shall be provided with protection against backflow and contamination of the water supply system. Water pumps, filters, softeners, tanks and all other appliances and devices that handle or treat potable water shall be protected against contamination. Backflow protection shall be provided prior to connection of any of the carwash equipment. This can be accomplished by one device. This will be verified on inspection.
Internal Plan Review (Res) Approved 04/15/2011
Mike Weisenborn
Internal Plan Review (Res) Rejected 03/22/2011 03/24/2011
Mike Weisenborn
Fire Plan Review Rejected 03/22/2011 03/24/2011
Jim Eden
Misc
Resolved
03/24/2011

Fire Department- The location of the underground storage tanks vary from drawing to drawing, which is correct? Action required - Make needed corrections.
Misc
Partial Correction
03/24/2011

Fire Department- Submit a Hazardous Materials Permit Application for review and approval. Incl;ude in the application Material Safety Data Sheets for the fuel products being stored and there quantities; tank, pump an piping specifications, detailed layout of the tank piping and appurtenances.
Misc
Resolved
03/24/2011

Fire Department- The fuel dispensers shall be protecrted by bollards. Provide a detail for dispenser layout.
Misc
Corrective Action Required
03/15/2011

Fire Department- 2006 IFC 2205.6 Warning signs. Warning signs shall be conspicuously posted within sight of each dispenser in the fuel-dispensing area and shall state the following: 1. No smoking. 2. Shut off motor. 3. Discharge your static electricity before fueling by touching a metal surface away from the nozzle. 4. To prevent static charge, do not reenter your vehicle while gasoline is pumping. 5. If a fire starts, do not remove nozzle—back away immediately. 6. It is unlawful and dangerous to dispense gasoline into unapproved containers. 7. No filling of portable containers in or on a motor vehicle. Place container on ground before filling. Action required - Provide signage.
Misc
Corrective Action Required
03/15/2011

Fire Department- 2006 IFC 2205.5 Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill-pipe openings. Action required - Show location of extinguisher. Verified at inspection.
Address numbers required
Resolved
03/24/2011

Fire Department- 2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action require - To be verified on inspection.
Portable fire extinguishers - general
Corrective Action Required
03/15/2011

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required - Show location on the plans.
Misc
Corrective Action Required
03/15/2011

Fire Department- 2006 IFC 1008.1.8.3 Locks and latches. The use of a double keyed deadbolt is no permitted. Action required - Deadbolt locks shall have a thumb latch.
Misc
Corrective Action Required
03/15/2011

Fire Department- 2006 IFC 2201.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor fuel-dispensing facilities and repair garages shall be in accordance with this chapter and the International Building Code, International Fuel Gas Code and the International Mechanical Code. Such operations shall include both operations that are accessible to the public and private operations. Action required - For information only.
Misc
Resolved
03/24/2011

Fire Department-2006 IFC 304.3.3 Capacity exceeding 1.5 cubic yards. Dumpsters and containers with an individual capacity of 1.5 cubic yards [40.5 cubic feet (1.15 m3)] or more shall not be stored in buildings or placed within 5 feet (1524 mm) of combustible walls, openings or combustible roof eave lines. Exceptions: 1. Dumpsters or containers in areas protected by an approved automatic sprinkler system installed throughout in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. 2. Storage in a structure shall not be prohibited where the structure is of Type I or IIA construction, located not less than 10 feet (3048 mm) from other buildings and used exclusively for dumpster or container storage. Action required - A detail for the trash enclosure is is provided, but the location is not shown on the site plan. Locate accordingly.
Misc
Corrective Action Required
03/24/2011

2203.2 Emergency disconnect switches. An approved, clearly identified and readily accessible emergency disconnect switch shall be provided at an approved location, to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. An emergency disconnect switch for exterior fuel dispensers shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel-dispensing operations, the emergency disconnect switch shall be installed at an approved location. Such devices shall be distinctly labeled as: EMERGENCY FUEL SHUTOFF. Signs shall be provided in approved locations. Action required: Show the location of the fuel shur-off.
Building Plan Review Rejected 03/22/2011 03/21/2011
Mike Weisenborn
Misc
Resolved
03/21/2011

Planning and Development - UDO Section 7.370 - CPTED Uses Specified. The following uses have been classified as "Uses with Conditions" per Article 9 of this Chapter, having been determined with a tendency toward an increased risk of crime. Specific conditions for such uses are found in Article 9 and shall be required to be met prior to receiving any zoning approval, business license or approval to occupy any commercial space. 1. Bank/Financial Services 2. Bank Drive-Thru Facility 3. Check Cashing and Payday Loan Business 4. Convience Store (C-Store) 5. Financial Services with Drive-up Window or Drive-Thru Facility 6. Pawn Shop 7. Title Loan Business, if performing on site cash transactions with $500 or more in cash on hand 8. Unattended Self-serve gas pumps 9. Unsecured Loan Busniness 10. Other similar uses shall meet the same standards as the above. Action required - This will be reviewed by the Planning and Development Department as part of the FDP approval. Approved as part of the FDP application.
Misc
Corrective Action Required
03/15/2011

Codes Administration - Plans for the canopy have not been provided. Action required - Provide plans for the canopy. Information shall include archictectural and structural. The acrchitectural elevations have been provided but the structural have not. Provide the structural plans for the canopy.
Misc
Resolved
03/21/2011

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - The plans do not show the required vertical grab bar. Make needed corrections. Added to details on Sheet A2.1.
Misc
Resolved
03/21/2011

Codes Administration - The project data indicates a construction type of II-B which is non-combustible construction. This is a combustible structure which is classified as type V-B construction. Action required - Make needed corrections to the construction type and associated requirements. Corrections have been made to the Code Study.
Bldg - Glazing - Human impact loads
Resolved
03/21/2011

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.4. Action required - Glass within 24 inches of the edge of a door shall meet this requirement. Make needed corrections. Corrections have been made.
Misc
Resolved
03/21/2011

Codes Administration - I am unable to locate construction details for the interior walls. Action required - Provide additional information. Information has been provided on Sheet A6.3.
Misc
Corrective Action Required
03/15/2011

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy. Action required - This comment is for information purposes.
Misc
Corrective Action Required
03/15/2011

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit. Action required - Provide documentation of approval from the Health Department. I have not yet received approval from the health department.
Misc
Resolved
03/21/2011

CA - The Final Development Plan must be approved prior to issuing full building permits. Action required - This comment is for information purposes.
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
03/15/2011

Codes Administration - 2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - Show how this requirement will be met. A note has been added to Sheet A1.1. Will verify on inspection.
Misc
Corrective Action Required
03/15/2011

Codes Administration - Information on the car wash equipment has not been provided. Action required - Provide additional information. Details for the equipment to be installed shall be provided for review and approval prior to installation.
Bldg - Toilet rooms - Floor surface and walls
Resolved
03/21/2011

Codes Administration - 2006 IBC 1210.1 - Floors. In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbent surface that extends upward onto the walls at least 6 inches. Action required - The only base reference I can find is for a 4" base and the restrooms require 6". Make needed corrections. Corrections have been made.
Bldg - Toilet rooms - Walls
Corrective Action Required
03/15/2011

Codes Administration - 2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture. Action required - If paint is to be used in this space it must be an epoxy paint. Make needed corrections. I believe the restroom walls are to be frp. This will be verified on inspection.
Misc
Corrective Action Required
03/15/2011

Codes Administration - A waste and vent riser diagram has not been provided. Action required - Provide additional information. The resubmittal did not include this information.
Misc
Corrective Action Required
03/15/2011

Codes Administration - A fixturing plan is not provided. Action required - Provide a fixturing plan. A complete review can not be completed until we know what equipment will be installed. The resubmittal did not include this information. Provide additional information.
Misc
Corrective Action Required
03/15/2011

Codes Administration - The plumbing plans are incomplete. The fixture schedule does not include all the fixtures and the water plan does not show water running to the mop sink. Action required - Make these corrections and any others as needed. The resbumittal did not include this information. Provide additional information.
Mech - Outdoor air required
Corrective Action Required
03/15/2011

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - Provide outdoor air calculations. The resubmital did not include this information. Provide additional information.
Final Development Plan Review Approved 01/10/2011 01/05/2011
Mike Weisenborn
License Tax Codes Approved 10/25/2010 11/02/2010
Mike Weisenborn
Internal Plan Review (Res) Rejected 11/02/2010
Mike Weisenborn
Fire Plan Review Rejected 10/25/2010 11/02/2010
Mike Weisenborn
Misc
Corrective Action Required
11/02/2010

Fire Department- The location of the underground storage tanks vary from drawing to drawing, which is correct? Action required - Make needed corrections.
Misc
Corrective Action Required
11/02/2010

Fire Department- Submit a Hazardous Materials Permit Application for review and approval. Incl;ude in the application Material Safety Data Sheets for the fuel products being stored and there quantities; tank, pump an piping specifications, detailed layout of the tank piping and appurtenances.
Misc
Corrective Action Required
11/02/2010

Fire Department- The fuel dispensers shall be protecrted by bollards. Provide a detail for dispenser layout.
Misc
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 2205.6 Warning signs. Warning signs shall be conspicuously posted within sight of each dispenser in the fuel-dispensing area and shall state the following: 1. No smoking. 2. Shut off motor. 3. Discharge your static electricity before fueling by touching a metal surface away from the nozzle. 4. To prevent static charge, do not reenter your vehicle while gasoline is pumping. 5. If a fire starts, do not remove nozzle—back away immediately. 6. It is unlawful and dangerous to dispense gasoline into unapproved containers. 7. No filling of portable containers in or on a motor vehicle. Place container on ground before filling. Action required - Provide signage.
Misc
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 2205.5 Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill-pipe openings. Action required - Show location of extinguisher.
Address numbers required
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action require - To be verified on inspection.
Portable fire extinguishers - general
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required - Show location on the plans.
Misc
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 1008.1.8.3 Locks and latches. The use of a double keyed deadbolt is no permitted. Action required - Deadbolt locks shall have a thumb latch.
Misc
Corrective Action Required
11/02/2010

Fire Department- 2006 IFC 2201.1 Scope. Automotive motor fuel-dispensing facilities, marine motor fuel-dispensing facilities, fleet vehicle motor fuel-dispensing facilities and repair garages shall be in accordance with this chapter and the International Building Code, International Fuel Gas Code and the International Mechanical Code. Such operations shall include both operations that are accessible to the public and private operations. Action required - For information only.
Misc
Corrective Action Required
11/02/2010

Fire Department-2006 IFC 304.3.3 Capacity exceeding 1.5 cubic yards. Dumpsters and containers with an individual capacity of 1.5 cubic yards [40.5 cubic feet (1.15 m3)] or more shall not be stored in buildings or placed within 5 feet (1524 mm) of combustible walls, openings or combustible roof eave lines. Exceptions: 1. Dumpsters or containers in areas protected by an approved automatic sprinkler system installed throughout in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. 2. Storage in a structure shall not be prohibited where the structure is of Type I or IIA construction, located not less than 10 feet (3048 mm) from other buildings and used exclusively for dumpster or container storage. Action required - A detail for the trash enclosure is is provided, but the location is not shown on the site plan. Locate accordingly.
Corrective Action Required
03/24/2011

Building Plan Review Rejected 10/25/2010 11/02/2010
Mike Weisenborn
Misc
Corrective Action Required
11/02/2010

Planning and Development - UDO Section 7.370 - CPTED Uses Specified. The following uses have been classified as "Uses with Conditions" per Article 9 of this Chapter, having been determined with a tendency toward an increased risk of crime. Specific conditions for such uses are found in Article 9 and shall be required to be met prior to receiving any zoning approval, business license or approval to occupy any commercial space. 1. Bank/Financial Services 2. Bank Drive-Thru Facility 3. Check Cashing and Payday Loan Business 4. Convience Store (C-Store) 5. Financial Services with Drive-up Window or Drive-Thru Facility 6. Pawn Shop 7. Title Loan Business, if performing on site cash transactions with $500 or more in cash on hand 8. Unattended Self-serve gas pumps 9. Unsecured Loan Busniness 10. Other similar uses shall meet the same standards as the above. Action required - This will be reviewed by the Planning and Development Department as part of the FDP approval.
Misc
Corrective Action Required
11/02/2010

Codes Administration - Plans for the canopy have not been provided. Action required - Provide plans for the canopy. Information shall include archictectural and structural.
Misc
Corrective Action Required
11/02/2010

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - The plans do not show the required vertical grab bar. Make needed corrections.
Misc
Corrective Action Required
11/02/2010

Codes Administration - The project data indicates a construction type of II-B which is non-combustible construction. This is a combustible structure which is classified as type V-B construction. Action required - Make needed corrections to the construction type and associated requirements.
Bldg - Glazing - Human impact loads
Corrective Action Required
11/02/2010

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.4. Action required - Glass within 24 inches of the edge of a door shall meet this requirement. Make needed corrections.
Misc
Corrective Action Required
11/02/2010

Codes Administration - I am unable to locate construction details for the interior walls. Action required - Provide additional information.
Misc
Corrective Action Required
11/02/2010

Codes Administration - For the Health Department inspection contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Occupancy approval is required by the City of Lee's Summit prior to issuance of any type of occupancy. Action required - This comment is for information purposes.
Misc
Corrective Action Required
11/02/2010

Codes Administration - For the Health Department permit approval contact Chris Saxton with the Jackson County Public Works Department, Environmental Services Division at 816-881-4455. Plan approval is required by the City of Lee's Summit prior to issuance of any type of permit. Action required - Provide documentation of approval from the Health Department.
Misc
Corrective Action Required
11/02/2010

CA - The Final Development Plan must be approved prior to issuing full building permits. Action required - This comment is for information purposes.
Bldg - Accessibility - Point of sale and service counters 1109.12.3
Corrective Action Required
11/02/2010

Codes Administration - 2006 IBC 1109.12.3 - Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required - Show how this requirement will be met.
Misc
Corrective Action Required
11/02/2010

Codes Administration - Information on the car wash equipment has not been provided. Action required - Provide additional information.
Bldg - Toilet rooms - Floor surface and walls
Corrective Action Required
11/02/2010

Codes Administration - 2006 IBC 1210.1 - Floors. In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbent surface that extends upward onto the walls at least 6 inches. Action required - The only base reference I can find is for a 4" base and the restrooms require 6". Make needed corrections.
Bldg - Toilet rooms - Walls
Corrective Action Required
11/02/2010

Codes Administration - 2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture. Action required - If paint is to be used in this space it must be an epoxy paint. Make needed corrections.
Misc
Corrective Action Required
11/02/2010

Codes Administration - A waste and vent riser diagram has not been provided. Action required - Provide additional information.
Misc
Corrective Action Required
11/02/2010

Codes Administration - A fixturing plan is not provided. Action required - Provide a fixturing plan. A complete review can not be completed until we know what equipment will be installed.
Misc
Corrective Action Required
11/02/2010

Codes Administration - The plumbing plans are incomplete. The fixture schedule does not include all the fixtures and the water plan does not show water running to the mop sink. Action required - Make these corrections and any others as needed.
Mech - Outdoor air required
Corrective Action Required
11/02/2010

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - Provide outdoor air calculations.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Commercial $2,707.50 $2,707.50 Paid 05/12/2011
9123001-Escrow Deposit $20,216.54 $20,216.54 Paid 05/12/2011
8350015-Water Meter Fee $1,482.00 $1,482.00 Paid 05/12/2011
8331401-Water Tap Fee $19,960.00 $19,960.00 Paid 05/12/2011
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/12/2011
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 5/31/2011 (2:45) 5/31/2011 at 12:00 AM 05/31/2011
Underslab Plumbing Inspection - Commercial Partial 6/21/2011 at 12:00 AM 06/21/2011
Misc
Corrective Action Required
06/21/2011
partial - all main drains approved to cover inspect water and floor sinks when ready
Underslab Electrical Inspection - Commercial Passed 06/24/2011
Underslab Plumbing Inspection - Commercial Passed 6/28/2011 6/28/2011 at 12:00 AM 06/28/2011
Misc
Resolved
06/28/2011
partial - all main drains approved to cover inspect water and floor sinks when ready
Footing Inspection - Commercial Passed 8/11/2011 (10:00) 8/11/2011 at 12:00 AM 08/11/2011
Sewer Service Inspection Partial 8/12/2011 (1:15) 8/12/2011 at 12:00 AM 08/12/2011
Misc
Corrective Action Required
08/12/2011
Sewer installed from separating tanks to north east corner of building. remaining from tanks to building and from northeast croner to main.
Sewer Service Inspection Passed 8/16/2011 (4:00) 8/16/2011 at 12:00 AM 08/16/2011
Misc
Resolved
08/16/2011
Sewer installed from separating tanks to north east corner of building. remaining from tanks to building and from northeast croner to main.
Water Service Inspection Passed 8/17/2011 (1:15) 8/17/2011 at 12:00 AM 08/17/2011
All Rough Inspection - Commercial Failed 08/30/2011
M305 PIPING SUPPORT
Corrective Action Required
08/30/2011
COMPLETE DUCTS ABOVE CEILING
Misc
Corrective Action Required
08/30/2011
GERNERAL PLUMBING- INSTALL NAIL PROTECION PLATES WHERE REQUIRED. INSTALL PLATE STRAPS WHERE TOP PLATES BORED MORE THATN 50%.
B2304 GENERAL CONSTRUCTION REQUIREMENTS
Corrective Action Required
08/30/2011
NAIL PATTERN ON ALL DBL GIRTER TRUSS AS PER PLANS. 2. SUPPORT RAFTERS OVER REAR CAR WASH AREA WHERE RAFTERS MEET VALLEY, AS PER PLANS. 3. INSTALL FRAMING FOR DRAFT STOP OR REVISE PLANS FOR CHANGE. 4. INSTALL DLB STUDS UNDER DBL GIRTER TRUSS. 5. PROVIDE FLUE CLEARANCE AT ALL FLUE PENETRATIONS THROUGH ROOF SHEATHING.
Underground Electrical Inspection - Commercial Partial 9/1/2011 9/1/2011 at 12:00 AM 09/01/2011
E300.5 Underground Installations
Corrective Action Required
09/01/2011
UNDERGROUND ELECTRICAL- APPROVED FROM TANK LOCATION & PUMPS LOCATIONS TO BUILDING.
E300.5 Underground Installations
Corrective Action Required
09/01/2011
EXTERIOR UNDERGROUND ELECTRICAL- EXTERIOR LIGHTING CURCUITS APPROVD FROM NORTH EAST CORNER OF BUILDING TO 60' NORTH- RECALL FOR REMAINING INSTALLATION WHEN READY.
All Rough Inspection - Commercial Failed 9/14/2011 at 12:00 AM 09/14/2011
M305 PIPING SUPPORT
Resolved
09/14/2011
COMPLETE DUCTS ABOVE CEILING
Misc
Resolved
09/14/2011
GERNERAL PLUMBING- INSTALL NAIL PROTECION PLATES WHERE REQUIRED. INSTALL PLATE STRAPS WHERE TOP PLATES BORED MORE THATN 50%.
B2304 GENERAL CONSTRUCTION REQUIREMENTS
Corrective Action Required
08/30/2011
2. SUPPORT RAFTERS OVER REAR CAR WASH AREA WHERE RAFTERS MEET VALLEY, AS PER PLANS. ( ENG APPROVED FRAMING WILL SEND LETTER) 3. INSTALL FRAMING FOR DRAFT STOP OR REVISE PLANS FOR CHANGE.( CHANGED TO NORTH SOUTH TRUSS ) NEED TO INSPECT BEFORE COVERING. 5. PROVIDE FLUE CLEARANCE AT ALL FLUE PENETRATIONS THROUGH ROOF SHEATHING. CAR WASH WEST SIDE.
Erosion Control Inspection Residential Failed 09/14/2011
All Rough Inspection - Commercial Partial 9/20/2011 (8:00 to 5:00) 9/20/2011 at 12:00 AM 09/20/2011
B2304 GENERAL CONSTRUCTION REQUIREMENTS
Corrective Action Required
09/14/2011
2. SUPPORT RAFTERS OVER REAR CAR WASH AREA WHERE RAFTERS MEET VALLEY, AS PER PLANS. 3. INSTALL FRAMING FOR DRAFT STOP OR REVISE PLANS FOR CHANGE. 5. PROVIDE FLUE CLEARANCE AT ALL FLUE PENETRATIONS THROUGH ROOF SHEATHING.
Misc
Corrective Action Required
09/20/2011
DRAFT STOP - TRUSS SHEETROCKED FROM ROOF DECK TO BOTTOM CORD OF TRUSS.
Piers/Caissons Inspection - Commercial Failed 09/22/2011
Misc
Corrective Action Required
09/22/2011
PARKING LOT LIGHT POLE PIERS- FAILED- PROVIDE HORIZONTAL REBAR WITHIN 12" OF BOTTOM OF HOLE AND VERTICAL BARS TO WITHIN 3" OF BOTTOM OF HOLE. RECALL WHEN COMPLETE NO GROUNDING INSTALLED
Piers/Caissons Inspection - Commercial Partial 9/22/2011 9/22/2011 at 12:00 AM 09/22/2011
Misc
Corrective Action Required
09/22/2011
PARKING LOT LIGHT POLE PIERS- APPROVED TO POUR COLUMNS- NO GROUND ROD INSTALLED AT PIER INSPECTION
Underground Electrical Inspection - Commercial Partial 9/22/2011 (8:00 to 5:00) 9/26/2011 at 12:00 AM 09/26/2011
E300.5 Underground Installations
Partial Correction
09/26/2011
UNDERGROUND ELECTRICAL- APPROVED FROM TANK LOCATION & PUMPS LOCATIONS TO BUILDING.
E300.5 Underground Installations
Partial Correction
09/26/2011
EXTERIOR UNDERGROUND ELECTRICAL- EXTERIOR LIGHTING CURCUITS APPROVD FROM NORTH EAST CORNER OF BUILDING TO 60' NORTH; REMAINDER OF BURIED CONDUIT TO FIVE LIGHT POLE BASES -- GROUNDS NOT YET APPROVED
Misc
Corrective Action Required
09/26/2011
GEC CONNECTION TO GROUND RODS NOT CAD WELDED PER DRAWING
Electrical Service Inspection Partial 9/30/2011 at 12:00 AM 09/30/2011
Misc
Corrective Action Required
09/30/2011
CLAMP AT G.E.C. CONNECTION TO WATER LINE NOT LISTED FOR THIS USE. UFER GROUND IN PLACE. SERVICE RELEASED.
Underground Electrical Inspection - Commercial Passed 9/30/2011 at 12:00 AM 09/30/2011
E300.5 Underground Installations
Resolved
09/30/2011
UNDERGROUND ELECTRICAL- APPROVED FROM TANK LOCATION & PUMPS LOCATIONS TO BUILDING.
E300.5 Underground Installations
Resolved
09/30/2011
EXTERIOR UNDERGROUND ELECTRICAL- EXTERIOR LIGHTING CURCUITS APPROVD FROM NORTH EAST CORNER OF BUILDING TO 60' NORTH; REMAINDER OF BURIED CONDUIT TO FIVE LIGHT POLE BASES -- GROUNDS NOT YET APPROVED
Misc
Resolved
09/30/2011
GEC CONNECTION TO GROUND RODS NOT CAD WELDED PER DRAWING
Above Ceiling Inspection Failed 10/20/2011
Misc
Corrective Action Required
10/20/2011
FRONT SALES ROOM- 1.COMPLETE PIPE INSULATION 2. TAPE AND SECURE ENDS OF HVAC FLEX DUCTS OFFICE-CONNECT RETURN AIR VENT IN OFFICE ROOM. REAR ROOM- SCHEULDE WHEN READY
All Rough Inspection - Commercial Passed 10/20/2011 at 12:00 AM 10/20/2011
B2304 GENERAL CONSTRUCTION REQUIREMENTS
Resolved
10/20/2011
2. SUPPORT RAFTERS OVER REAR CAR WASH AREA WHERE RAFTERS MEET VALLEY, AS PER PLANS. 3. INSTALL FRAMING FOR DRAFT STOP OR REVISE PLANS FOR CHANGE. 5. PROVIDE FLUE CLEARANCE AT ALL FLUE PENETRATIONS THROUGH ROOF SHEATHING.
Misc
Resolved
10/20/2011
DRAFT STOP - TRUSS SHEETROCKED FROM ROOF DECK TO BOTTOM CORD OF TRUSS.
Electrical Service Inspection Passed 10/20/2011 at 12:00 AM 10/20/2011
Misc
Resolved
10/20/2011
CLAMP AT G.E.C. CONNECTION TO WATER LINE NOT LISTED FOR THIS USE
Above Ceiling Inspection Partial 10/26/2011 at 12:00 AM 10/26/2011
Misc
Corrective Action Required
10/20/2011
FRONT SALES ROOM-APPROVED TO CEILING TILE. OFFICE-CONNECT RETURN AIR VENT IN OFFICE ROOM. REAR ROOM- SCHEULDE WHEN READY
Gas Service Inspection - Commercial Failed 11/3/2011 at 12:00 AM 11/02/2011
Misc
Corrective Action Required
11/02/2011
1. REVISE PLANS SHOWING NEW LOCATION OF GAS METER AND PIPE SIZING PRESSURE APPROVED AT THIS TIME- PENDING APPROVAL OF CHANGE IN SIZE AND LOCATION
Gas Service Inspection - Commercial Passed 11/08/2011
Misc
Resolved
11/08/2011
1. REVISE PLANS SHOWING NEW LOCATION OF GAS METER AND PIPE SIZING PRESSURE APPROVED AT THIS TIME- PENDING APPROVAL OF CHANGE IN SIZE AND LOCATION
Above Ceiling Inspection Passed 11/10/2011 at 12:00 AM 11/10/2011
Misc
Resolved
11/10/2011
FRONT SALES ROOM-APPROVED TO CEILING TILE. OFFICE-CONNECT RETURN AIR VENT IN OFFICE ROOM. REAR ROOM- SCHEULDE WHEN READY
Occupancy Inspection - Fire Temporary C of O 11/15/2011 at 12:00 AM 11/15/2011
Misc
Corrective Action Required
11/15/2011
AHU #2 duct detection not functioning - duct detection needs to initiate an audible alarm at the remote test/reset station with HVAC shut down.
Occupancy Inspection - Fire Passed 11/16/2011 at 12:00 AM 11/16/2011
Misc
Corrective Action Required
11/15/2011
AHU #2 duct detection not functioning - duct detection needs to initiate an audible alarm at the remote test/reset station with HVAC shut down.
Occupancy Inspection - Codes Commercial Failed 11/15/2011 at 12:00 AM 11/16/2011
Misc
Corrective Action Required
11/16/2011
CODES- 1. COMPLETE RESTROOMS PER PLANS, INSTALL VERTICAL GRAB BARS PER ANSI. 2. INSTALL PARTIONS AT STALLS 3. INSTALL CODE APPROVED "POS " COUNTER. 4. PROVIDE NO SMOKING SIGN AT FRONT DOOR. 5. LAWN SPRINKLER PERMIT REQUIRED. SUBMIT BACKFLOW TEST TO WATER DEPARTMENT
Misc
Corrective Action Required
11/16/2011
1. FIRE DEPARTMENT- APPROVED FOR TCO 2. PLANNING DEPARTMENT- PENDING 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT- NOT APPROVED FOR TCO CONTRACTOR MUST PROVIDE APPROVAL FROM ALL DEPARTMENTS FOR TCO.
Misc
Corrective Action Required
11/16/2011
APPROVED TO STOCK NOT APPROVED FOR OCCUPANCY NOT APPROVED FOR PUBLIC USE
Occupancy Inspection - Planning Failed 11/15/2011 at 3:00 PM 11/16/2011
Corrective Action Required
11/15/2011
Required for Temporary Certificate of Occupancy: All support columns for the gas pump canopy shall be covered in decorative brick from grade to the underside of the canopy as shown on the approved Final Development Plan.
Corrective Action Required
11/15/2011
Required for Final Certificate of Occupancy: All parking lot pole light fixtures shall be changed out to LED light fixtures as shown on the approved Final Development Plan.
Corrective Action Required
11/15/2011
Required for Final Certificate of Occupancy: The vinyl fence screening shall be installed to screen the rear HVAC units.
Corrective Action Required
11/15/2011
Required for Final Certificate of Occupancy: A "No Loitering / Trespassing" sign shall be prominently displayed near the front entrance of the building.
Corrective Action Required
11/16/2011
Required for Final Certificate of Occupancy: Height strips shall be placed at the front entrance of the building.
Corrective Action Required
11/16/2011
Required for Final Certificate of Occupancy: An automatic door lock shall be installed capable of locking the front door from the cashier counter.
Occupancy Inspection - Planning Temporary C of O 11/17/2011
Resolved
03/01/2012
Required for Final Certificate of Occupancy: All support columns for the gas pump canopy shall be covered in decorative brick from grade to the underside of the canopy as shown on the approved Final Development Plan. Decorative brick shall be installed by January 17, 2012 per written confirmation from the General Contactor.
Resolved
03/01/2012
Required for Final Certificate of Occupancy: All parking lot pole light fixtures shall be changed out to LED light fixtures as shown on the approved Final Development Plan.
Resolved
03/01/2012
Required for Final Certificate of Occupancy: The vinyl fence screening shall be installed to screen the rear HVAC units.
Resolved
03/01/2012
Required for Final Certificate of Occupancy: A "No Loitering / Trespassing" sign shall be prominently displayed near the front entrance of the building.
Resolved
03/01/2012
Required for Final Certificate of Occupancy: Height strips shall be placed at the front entrance of the building.
Corrective Action Required
11/17/2011
Required for Final Certificate of Occupancy: An automatic door lock shall be installed capable of locking the front door from the cashier counter. Refer to Section 9.210.D of the City's Unified Development Ordinance.
Occupancy Inspection - Codes Commercial Failed 11/16/2011 at 12:00 AM 11/17/2011
Misc
Corrective Action Required
11/15/2011
CODES- 1. COMPLETE RESTROOMS PER PLANS, INSTALL VERTICAL GRAB BARS PER ANSI. 2. INSTALL PARTIONS AT STALLS 3. INSTALL CODE APPROVED "POS " COUNTER. 4. PROVIDE NO SMOKING SIGN AT FRONT DOOR. 5. INSTALL BACKFLOW DEVISE FOR CAR WASH WATER PIPING. 6. DISCONNECT LOCATION FOR AC UNITS AT REAR OF BUILDING.
Misc
Corrective Action Required
11/15/2011
1. FIRE DEPARTMENT- APPROVED FOR TCO 2. PLANNING DEPARTMENT- PENDING 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT- NOT APPROVED FOR TCO TCO WILL BE ISSED WHEN CONTRACTOR HAS COMPLETED ALL DEPARTMENT ISSUES AND REQUESTED BY CONTRACTOR.
Misc
Corrective Action Required
11/15/2011
APPROVED TO STOCK NOT APPROVED FOR OCCUPANCY NOT APPROVED FOR PUBLIC USE
Occupancy Inspection - Codes Commercial Failed 11/17/2011 at 12:00 AM 11/17/2011
Misc
Corrective Action Required
11/17/2011
CODES- 1. COMPLETE RESTROOMS PER PLANS, INSTALL VERTICAL GRAB BARS PER ANSI. BY 11-18-11 2. INSTALL PARTIONS AT STALLS BY -12-9-11 3. INSTALL CODE APPROVED "POS " COUNTER.BY 12-9-11 4. PROVIDE NO SMOKING SIGN AT FRONT DOOR. BY 11-18-11
Misc
Corrective Action Required
11/17/2011
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT- NOT APPROVED FOR TCO SCHEDULED FOR 11-18-11
Misc
Corrective Action Required
11/17/2011
APPROVED TO STOCK NOT APPROVED FOR OCCUPANCY NOT APPROVED FOR PUBLIC USE Install no smoking sign and vertical grab bar by 11-18-11 Install restroom wall partitions and accessible “POS” counter by 12-9-11 Obtain permit for Lawn sprinkler by 12-9-11 Complete planning department issues by 1-17-12
Occupancy Inspection - Codes Commercial Temporary C of O 11/18/2011 at 12:00 AM 11/18/2011
Misc
Corrective Action Required
11/17/2011
CODES- 2. INSTALL PARTIONS AT STALLS BY -12-9-11(BEING INSTALLED ON 11-18-11) 3. INSTALL CODE APPROVED "POS " COUNTER.BY 12-9-11 4. OBTAIN LAWN SPRINKLER PERMIT BY 12-9-11
Misc
Corrective Action Required
11/17/2011
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED FOR TCO FOR TCO
Misc
Corrective Action Required
11/17/2011
Install restroom wall partitions(INSTALLING DURING INSPECTION 11-18-11 INSTALL accessible “POS” counter by 12-9-11 Obtain permit for Lawn sprinkler by 12-9-11 Complete planning department issues by 1-17-12
Occupancy Inspection - Codes Commercial Failed 12/9/2011 at 12:00 AM 12/09/2011
Misc
Resolved
12/09/2011
CODES- 2. INSTALL PARTIONS AT STALLS BY -12-9-11(BEING INSTALLED ON 11-18-11) 3. INSTALL CODE APPROVED "POS " COUNTER.BY 12-9-11 4. OBTAIN LAWN SPRINKLER PERMIT BY 12-9-11
Misc
Resolved
12/15/2011
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED 6. HEALTH DEPT APPROVAL-BY 12-16-11
Misc
Corrective Action Required
11/18/2011
Complete planning department issues by 1-17-12
Occupancy Inspection - Codes Commercial Temporary C of O 12/15/2011
Misc
Corrective Action Required
12/09/2011
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED 6. HEALTH DEPT APPROVED
Misc
Corrective Action Required
12/09/2011
Complete planning department issues by 1-17-12
Occupancy Inspection - Codes Commercial Temporary C of O 01/25/2012
Misc
Corrective Action Required
12/15/2011
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED 6. HEALTH DEPT APPROVED
Misc
Corrective Action Required
12/15/2011
AS PER REQUEST -AND APPROVED BY PLANNING TCO HAS BEEN EXTENDED TO 3-2-12 PER CHRIS HUGHEY-BOB MCKAY-MH. SEE PERMIT FILE
Occupancy Inspection - Codes Commercial Temporary C of O 2/29/2012 2/29/2012 at 12:00 AM 02/29/2012
Misc
Corrective Action Required
01/25/2012
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED 6. HEALTH DEPT APPROVED
Misc
Corrective Action Required
01/25/2012
AS PER REQUEST -AND APPROVED BY PLANNING TCO HAS BEEN EXTENDED TO 3-15-12 PER CHRIS HUGHEY
Occupancy Inspection - Planning Temporary C of O 2/29/2012 at 12:00 AM 03/01/2012
Resolved
03/15/2012
Required for Final Certificate of Occupancy: An automatic door lock shall be installed capable of locking the front door from the cashier counter. Refer to Section 9.210.D of the City's Unified Development Ordinance.
Occupancy Inspection - Planning Temporary C of O 03/15/2012
Resolved
03/22/2012
Required for Final Certificate of Occupancy: The third accessible parking space shall have the accessible parking symbol painted on the concrete of the space and shall have a stripped 5' lane added to the on either side of the third parking space. Another option would be to remove the accessible signage for the third space. Only two accessible parking spaces are required for this site.
Occupancy Inspection - Planning Passed 03/22/2012
Occupancy Inspection - Codes Commercial Full C of O 03/23/2012
Misc
Resolved
03/23/2012
1. FIRE DEPARTMENT- APPROVED FOR C OF O 2. PLANNING DEPARTMENT- TCO 60 DAYS 1-17-12 3. WATER DEPARTMENT- PENDING 4. PUBLIC WORKS -APPROVED FOR TCO 5. CODES DEPT. APPROVED 6. HEALTH DEPT APPROVED
Misc
Resolved
03/23/2012
AS PER REQUEST -AND APPROVED BY PLANNING TCO HAS BEEN EXTENDED TO 3-15-12 PER CHRIS HUGHEY
Piers/Caissons Inspection - Commercial Passed 03/26/2012
Misc
Resolved
03/26/2012
PARKING LOT LIGHT POLE PIERS- APPROVED TO POUR COLUMNS- NO GROUND ROD INSTALLED AT PIER INSPECTION
Documents & Images
Date Uploaded File Type Document Name
05/12/2011 Letter Plan Review Conditions
05/12/2011 Letter Building Permit
04/11/2011 Letter Fire Building Plan Review
11/02/2010 Letter Plan Review Conditions
09/30/2011 Letter Inspection Summary
09/26/2011 Letter Inspection Summary
09/22/2011 Letter Inspection Summary
09/22/2011 Letter Inspection Summary
09/20/2011 Letter Inspection Summary
09/14/2011 Letter Inspection Summary
09/14/2011 Letter Inspection Summary
09/01/2011 Letter Inspection Summary
08/30/2011 Letter Inspection Summary
08/17/2011 Letter Inspection Summary
08/16/2011 Letter Inspection Summary
11/17/2011 Letter Inspection Summary
11/17/2011 Letter Inspection Summary
08/12/2011 Letter Inspection Summary
08/11/2011 Letter Inspection Summary
06/28/2011 Letter Inspection Summary
06/24/2011 Letter Inspection Summary
06/21/2011 Letter Inspection Summary
06/21/2011 Letter Inspection Summary
05/31/2011 Letter Inspection Summary
10/05/2011 Drawing 20111005074722575.pdf
03/31/2011 Drawing Car wash equipment
03/24/2011 Letter Plan Review Conditions
11/08/2011 Plans Revised Gas Piping Plan
11/08/2011 Letter Inspection Summary
11/10/2011 Letter Inspection Summary
11/15/2011 Letter Fire Loss Reduction Form
11/15/2011 Letter Inspection Summary
11/16/2011 Letter Fire Loss Reduction Form
11/16/2011 Letter Inspection Summary
11/16/2011 Letter Inspection Summary
10/20/2011 Letter Inspection Summary
10/20/2011 Letter Inspection Summary
10/26/2011 Letter Inspection Summary
11/02/2011 Letter Inspection Summary
11/16/2011 Letter Planning Inspection Summary
11/17/2011 Letter Planning Inspection Summary
11/18/2011 Letter Temporary Certificate of Occupancy
11/30/2011 Activity Document 20111130102501473.pdf
11/30/2011 Activity Document 20111130102702567.pdf
11/30/2011 Activity Document 20111130102810644.pdf
12/01/2011 Activity Document 20111201120940176.pdf
12/09/2011 Letter Inspection Summary
12/15/2011 Letter Temporary Certificate of Occupancy
12/16/2011 Letter Health Dept. e-mail
01/27/2012 Letter 20120127091415940.pdf
03/01/2012 Letter Planning Inspection Summary
02/29/2012 Letter Temporary Certificate of Occupancy
01/25/2012 Letter Temporary Certificate of Occupancy
03/15/2012 Letter Planning Inspection Summary
03/26/2012 Letter Inspection Summary
03/26/2012 Letter Final Certificate of Occupancy
03/22/2012 Letter Planning Inspection Summary
03/23/2012 Letter Field Certificate of Occupancy
06/21/2013 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home