Summary
B1001246
Building Permit - Commercial
Certificate of Occupancy
NEW COMMERCIAL
New shell building with one tenant space completely built out
10/08/2010
11/15/2010
05/07/2011
05/27/2011
Locations
Contacts
ALLENS ELECTRIC, Address:132 S HIGH ST  
INTEGRAL CONSTRUCTION SERVICES, INC., Address:303 SW MARKET  
CL HOWERTON ENTERPRISES, Address:40303 E 150TH ST  
E & Q HEATING AND COOLING, Address:5 SW 4TH ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/11/2010
Mike Weisenborn
Building Plan Review Approved 11/16/2010 11/11/2010
Mike Weisenborn
Misc
Resolved
11/11/2010

Codes Administration - 2006 IBC 503.1 - General. The height and area for buildings of different construction types shall be goverened by the intended use of the building and shall not exceed the limits in Table 203 except as modified hereafter. Each part of a building included within the exterior walls or the exterior walls and fire walls where provided shall be permitted to be a separate building. Action required - In the Occupancy Classification on Sheet A0 the occupancy type is listed as a business use but the base allowable area provided is 6000 s.f. which is an assembly use. Make needed corrections to the calculations for a business use.
Misc
Resolved
11/11/2010

Codes Administration - The area of the building provided in the Occupancy Classification is confusing as it appears that the basement is included in the actual area. A basement is not included in the allowable area of the first floor. Action required - Provide separate square footages for the basement and the floor at grade level.
Accessibility - Water closet - Grab bars
Corrective Action Required
11/08/2010

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - The height of the bottom of the vertical grab bar is not indicated on the toilet elevations on Sheet A0 and the grab bar is not shown at all on the elvations on Sheet A7. This has not been clearly corrected on the plans. This will be verified on inspection.
Accessibility - Water closet - Clearance around
Resolved
11/11/2010

Codes Administration - ICC/ANSI A117.1 2003 604.3.1 - Size. A clearance around a water closet 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall, shall be provided. Action required - The restrooms do not meet this requirement as the lavatory is located within the required clear space. Make needed corrections.
Accessibility - Water closet - Clearance overlap
Resolved
11/11/2010

Codes Administration - ICC/ANSI A117.1 2003 604.3.2 - Overlap. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dispensers, sanitary napkin receptacles, coat hooks, shelves, accessible routes, clear floor space at other fixtures and the turning space. No other fixtures or obstructions shall be within the required water closet clearance. Action required - The restrooms do not meet this requirement as the lavatory is located within the required clear space. Make needed corrections.
Misc
Resolved
11/11/2010

Codes Administration - The plumbing sheet needs to be revised for the relocation of the grinder. Action required - Make needed corrections.
Plumb - Separate facilities
Resolved
11/11/2010

Codes Administration - 2006 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (See code for possible exceptions.) Action required - The restrooms is Lease Space 1 need to be indicated as men's and women's. Make needed corrections.
Misc
Resolved
11/11/2010

Codes Administration - I am unable to locate the finish schedule. Action required - Please provide additional information. Make sure the the floor, base and wall finishes of the restrooms meet the requirements of Chapter 12 of the 2006 IBC.
Bldg - Accessibility - Kitchens and kitchenettes - 1109.4
Resolved
11/11/2010

Codes Administration - 2006 IBC 1109.4 - Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC A117.1. Action required - Show compliance with this code section for both the waiting area and breakroom sinks.
Misc
Resolved
11/11/2010

Codes Administration - The architectural plans show a lavatory in the stairwell. Action required - Make needed corrections.
Misc
Resolved
11/11/2010

Codes Administration - I am unable to locate details for the construction of the stairs. Action required - Make needed corrections.
Bldg - Handrail - Extensions
Resolved
11/11/2010

Codes Administration - 2006 IBC 1012.5 - Handrail Extensions. Handrails shall return to a wall, guard or the walking surface or shall be continuous to the handrail of an adjacent stair flight or ramp run. At stairways where handrails are not continuous between flights, the handrails shall extend horizontally at least 12 inches beyond the top riser and continue to slope for the depth of one tread beyond the bottom riser. At ramps where handrails are not continuous between runs, the handrail shall extend horizontally above the landing 12 inches minimum beyond the top and bottom ramps. Action required - Section 2 on Sheet A2 shows the handrail leveling off at the nose of the first tread. Make needed corrections.
Misc
Resolved
11/11/2010

Codes Administration - It appears that there is not a wall along the bottom 3 steps but Section 2 on Sheet A2 does detail this. Action required - Provide information on how the handrail is to be installed at the bottom of the stairs on the open side. Guard requirements do not kick in as the top open step does not appear to be more than 30 inches above the floor surface.
Misc
Corrective Action Required
11/08/2010

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application. Action required - Provide two (2) copies of both the floor and roof truss systems which have been signed and sealed by an engineer licensed in the State of Missouri. This information is not required for permit approval or issuance but shall be provided prior to inspection of the framing. The roof truss package has been provided but not the floor system. Provide additional information.
Bldg - Glazing - Human impact loads
Corrective Action Required
11/08/2010

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.4. Action required - Glass with either vertical edge of a door is required to meet this requirement. To be verified on inspection.
Misc
Resolved
11/11/2010

Codes Administration - The plans show that some of the tenant spaces are separated by a one-hour fire-resistive wall but no indication of rated doors on the door schedule. There is no requirement in the code to separate one business tenant space from another tenant space of the same occupancy type. An assembly space is required to be separated from a B occupancy but that requires 2-hour fire-resistive barrier. Action required - If the one-hour fire-resistive walls are to be built as shown on the plans they must meet all the requirements including opening and penetration protection. Make needed corrections to the plans.
Misc
Corrective Action Required
11/08/2010

Codes Administration - Information on the grinder pump has not been provided. Section 712.2 requires both a check valve and a full open valve on the discharge side but the plans show only a BFP. The plans do not indicate how the waste from the grinder pump is to be tied into the building drain. Action required - Proper installation will be verified on inspection.
Mech - Outdoor air required
Resolved
11/11/2010

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - Provide the calculations for the required outdoor air.
Misc
Resolved
11/11/2010

Codes Administration - The mechanical plans do not include specifications for the installation of the system or for the furnaces being installed. Action required - Provide additional information.
Misc
Resolved
11/11/2010

Codes Administration - The plumbing plans call for cast iron waste and vent lines and there are no specifications for the installation of the plumbing systems. Action required - If a material other than cast iron is to be used it needs to be indicated on the plans. Provide specifications for the plumbing installation.
Misc
Resolved
11/11/2010

Codes Administration - The electrical plans do not include specifications for installation of the electrical or panel schedules. Action required - Provide additional information.
Fire Plan Review Approved 11/16/2010 11/09/2010
Jim Eden
Misc
Resolved
11/09/2010

Fire Department- 2006 IFC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702 of the International Building Code. Action required - Provide exterior egress illumination.
Address numbers required
Corrective Action Required
11/08/2010

Fire Department- 2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action required - Adresses shall be posted on the front and rears door of each space.Verified at inspection.
Misc
Resolved
11/09/2010

Fire Department- 2006 IFC 703.1- Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Action required - Verified at inspection. 11/9/2010- the walls are no longer going to be rated.
Misc
Corrective Action Required
11/08/2010

Fire Department- 2006 IFC 901.5.1- Occupancy. It shall be unlawful to occupy any portion of a building or structure until the required fire detection, alarm and suppression systems have been tested and approved. Action required - For information purposes.
Portable fire extinguishers - general
Corrective Action Required
11/08/2010

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required - For information only- Fire extinguishers shall be a minimum size of 2A:10B:C.
Misc
Resolved
11/09/2010

Fire Department- Unable to determine which doors are part of the rated wall assemblies. The notations on the Code Review drawings do not match the section drawings, and there is no listing of rated door and frame lassemblies on the Door and Frame Schedule. Action required - Please clarify. 11/9/2010- The separation walls are no longer going to be rated.
Internal Plan Review (Res) Rejected 10/22/2010 11/08/2010
Mike Weisenborn
Final Development Plan Review Approved 10/22/2010 11/08/2010
Mike Weisenborn
License Tax Codes Approved 10/22/2010 11/08/2010
Mike Weisenborn
Building Plan Review Rejected 10/22/2010 11/08/2010
Mike Weisenborn
Misc
Corrective Action Required
11/03/2010

Codes Administration - 2006 IBC 503.1 - General. The height and area for buildings of different construction types shall be goverened by the intended use of the building and shall not exceed the limits in Table 203 except as modified hereafter. Each part of a building included within the exterior walls or the exterior walls and fire walls where provided shall be permitted to be a separate building. Action required - In the Occupancy Classification on Sheet A0 the occupancy type is listed as a business use but the base allowable area provided is 6000 s.f. which is an assembly use. Make needed corrections to the calculations for a business use.
Misc
Corrective Action Required
11/03/2010

Codes Administration - The area of the building provided in the Occupancy Classification is confusing as it appears that the basement is included in the actual area. A basement is not included in the allowable area of the first floor. Action required - Provide separate square footages for the basement and the floor at grade level.
Accessibility - Water closet - Grab bars
Corrective Action Required
11/03/2010

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall. Action required - The height of the bottom of the vertical grab bar is not indicated on the toilet elevations on Sheet A0 and the grab bar is not shown at all on the elvations on Sheet A7. Make needed corrections.
Accessibility - Water closet - Clearance around
Corrective Action Required
11/03/2010

Codes Administration - ICC/ANSI A117.1 2003 604.3.1 - Size. A clearance around a water closet 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall, shall be provided. Action required - The restrooms do not meet this requirement as the lavatory is located within the required clear space. Make needed corrections.
Accessibility - Water closet - Clearance overlap
Corrective Action Required
11/03/2010

Codes Administration - ICC/ANSI A117.1 2003 604.3.2 - Overlap. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dispensers, sanitary napkin receptacles, coat hooks, shelves, accessible routes, clear floor space at other fixtures and the turning space. No other fixtures or obstructions shall be within the required water closet clearance. Action required - The restrooms do not meet this requirement as the lavatory is located within the required clear space. Make needed corrections.
Misc
Corrective Action Required
11/03/2010

Codes Administration - The plumbing sheet needs to be revised for the relocation of the grinder. Action required - Make needed corrections.
Plumb - Separate facilities
Corrective Action Required
11/03/2010

Codes Administration - 2006 IPC 403.2 - Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (See code for possible exceptions.) Action required - The restrooms is Lease Space 1 need to be indicated as men's and women's. Make needed corrections.
Misc
Corrective Action Required
11/03/2010

Codes Administration - I am unable to locate the finish schedule. Action required - Please provide additional information. Make sure the the floor, base and wall finishes of the restrooms meet the requirements of Chapter 12 of the 2006 IBC.
Bldg - Accessibility - Kitchens and kitchenettes - 1109.4
Corrective Action Required
11/08/2010

Codes Administration - 2006 IBC 1109.4 - Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC A117.1. Action required - Show compliance with this code section for both the waiting area and breakroom sinks.
Misc
Corrective Action Required
11/08/2010

Codes Administration - The architectural plans show a lavatory in the stairwell. Action required - Make needed corrections.
Misc
Corrective Action Required
11/08/2010

Codes Administration - I am unable to locate details for the construction of the stairs. Action required - Make needed corrections.
Bldg - Handrail - Extensions
Corrective Action Required
11/08/2010

Codes Administration - 2006 IBC 1012.5 - Handrail Extensions. Handrails shall return to a wall, guard or the walking surface or shall be continuous to the handrail of an adjacent stair flight or ramp run. At stairways where handrails are not continuous between flights, the handrails shall extend horizontally at least 12 inches beyond the top riser and continue to slope for the depth of one tread beyond the bottom riser. At ramps where handrails are not continuous between runs, the handrail shall extend horizontally above the landing 12 inches minimum beyond the top and bottom ramps. Action required - Section 2 on Sheet A2 shows the handrail leveling off at the nose of the first tread. Make needed corrections.
Misc
Corrective Action Required
11/08/2010

Codes Administration - It appears that there is not a wall along the bottom 3 steps but Section 2 on Sheet A2 does detail this. Action required - Provide information on how the handrail is to be installed at the bottom of the stairs on the open side. Guard requirements do not kick in as the top open step does not appear to be more than 30 inches above the floor surface.
Misc
Corrective Action Required
11/08/2010

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application. Action required - Provide two (2) copies of both the floor and roof truss systems which have been signed and sealed by an engineer licensed in the State of Missouri. This information is not required for permit approval or issuance but shall be provided prior to inspection of the framing.
Bldg - Glazing - Human impact loads
Corrective Action Required
11/08/2010

Codes Administration - 2003 IBC 2406.1 - Human impact loads. Individual glazed areas, including glass mirrors, in hazardous locations as defined in Section 2406.3 shall comply with Sections 2406.1 through 2406.1.4. Action required - Glass with either vertical edge of a door is required to meet this requirement. Make needed corrections to the window next to door 4.
Misc
Corrective Action Required
11/08/2010

Codes Administration - The plans show that some of the tenant spaces are separated by a one-hour fire-resistive wall but no indication of rated doors on the door schedule. There is no requirement in the code to separate one business tenant space from another tenant space of the same occupancy type. An assembly space is required to be separated from a B occupancy but that requires 2-hour fire-resistive barrier. Action required - If the one-hour fire-resistive walls are to be built as shown on the plans they must meet all the requirements including opening and penetration protection. Make needed corrections to the plans.
Misc
Corrective Action Required
11/08/2010

Codes Administration - Information on the grinder pump has not been provided. Section 712.2 requires both a check valve and a full open valve on the discharge side but the plans show only a BFP. The plans do not indicate how the waste from the grinder pump is to be tied into the building drain. Action required - Provide additional information.
Mech - Outdoor air required
Corrective Action Required
11/08/2010

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - Provide the calculations for the required outdoor air.
Misc
Corrective Action Required
11/08/2010

Codes Administration - The mechanical plans do not include specifications for the installation of the system or for the furnaces being installed. Action required - Provide additional information.
Misc
Corrective Action Required
11/08/2010

Codes Administration - The plumbing plans call for cast iron waste and vent lines and there are no specifications for the installation of the plumbing systems. Action required - If a material other than cast iron is to be used it needs to be indicated on the plans. Provide specifications for the plumbing installation.
Misc
Corrective Action Required
11/08/2010

Codes Administration - The electrical plans do not include specifications for installation of the electrical or panel schedules. Action required - Provide additional information.
Fire Plan Review Rejected 10/22/2010 11/03/2010
Mike Weisenborn
Misc
Corrective Action Required
11/03/2010

Fire Department- 2006 IFC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702 of the International Building Code. Action required - Provide exterior egress illumination.
Address numbers required
Corrective Action Required
11/03/2010

Fire Department- 2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action required - Adresses shall be posted on the front and rears door of each space.Verified at inspection.
Misc
Corrective Action Required
11/03/2010

Fire Department- 2006 IFC 703.1- Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Action required - Verified at inspection.
Misc
Corrective Action Required
11/03/2010

Fire Department- 2006 IFC 901.5.1- Occupancy. It shall be unlawful to occupy any portion of a building or structure until the required fire detection, alarm and suppression systems have been tested and approved. Action required - For information purposes.
Portable fire extinguishers - general
Corrective Action Required
11/03/2010

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required - For information only- Fire extinguishers shall be a minimum size of 2A:10B:C.
Misc
Corrective Action Required
11/03/2010

Fire Department- Unable to determine which doors are part of the rated wall assemblies. The notations on the Code Review drawings do not match the section drawings, and there is no listing of rated door and frame lassemblies on the Door and Frame Schedule. Action required - Please clarify.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Commercial $2,093.80 $2,093.80 Paid 11/15/2010
9110073-Right of Way Permit Fee $60.00 $60.00 Paid 11/15/2010
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/15/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Framing Inspection - Commercial Not Ready 11/22/2010 at 12:00 AM 11/22/2010
Misc
Corrective Action Required
11/22/2010
PROGRESSIVE INSPECTION OF FRAMING & SKIN SYSTEM CONSTRUCTION IN PROGRESS: TRUSS DETAIL DRAWING(S) NOT FOUND ON SITE; EXPANSION ANCHORS BEING INSTALLED AT EXTERIOR WALL SILL PLATE IN LIEU OF CAST-IN ANCHOR BOLTS PER DRAWINGS -- MUST BE INSTALLED PER MANUFACTURERS INSTRUCTIONS AND MUST BE INSPECTED DURING INSTALLATION
Rough Framing Inspection - Commercial Not Ready 11/23/2010 at 12:00 AM 11/23/2010
Misc
Partial Correction
11/23/2010
SETTING OF EPOXY-SECURED EXTERIOR WALL SILL PLATE ANCHOR BOLTS: IN PROGRESS AT NORTH HALF OF BUILDING;
Misc
Corrective Action Required
11/23/2010
REQUESTED INSPECTION OF ROOF SHEATHING NOT READY FOR INSPECTION: LADDER(S) NOT IN PLACE
Rough Framing Inspection - Commercial Partial 11/24/2010 at 12:00 AM 11/24/2010
Misc
Partial Correction
11/23/2010
SETTING OF EPOXY-SECURED EXTERIOR WALL SILL PLATE ANCHOR BOLTS: IN PROGRESS AT NORTH HALF OF BUILDING;
Misc
Partial Correction
11/24/2010
REQUESTED INSPECTION OF ROOF SHEATHING FASTENING: NO ISSUES FOUND AT MAIN ROOF; CLERESTORY ROOF NOT READY FOR INSPECTION -- LADDER NOT IN PLACE FOR INSPECTION ACCESS
Misc
Corrective Action Required
11/24/2010
JACK TRUSSES AT CLERSTORY ROOF STRUCTURE: NO HANGERS FOUND INSTALLED
Misc
Corrective Action Required
11/24/2010
OVER-ALL READINESS FOR FRAMING INSPECTION: WORK CONTINUES IN PROGRESS AS OF 11/23/2010 -- NOT FULLY READY FOR INSPECTION. RAIN 11/24/2010 -- NO ACTIVITY ON FOUND SITE
All Rough Inspection - Commercial Partial 12/21/2010 at 12:00 AM 12/21/2010
Misc
Corrective Action Required
03/01/2011
INSTALLATION OF SIMPSON STRONGWALL PANELS: IN PROGRESS
In-wall Inspection Partial 12/29/2010 at 12:00 AM 12/29/2010
Misc
Partial Correction
12/29/2010
OK TO COVER WHEN READY FRAMING AND IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: LEASE SPACE 2 NORTH WALL + SOUTH WALL EXCEPT ALONG STAIRWELL; LEASE SPACE 3 NORTH, WEST AND SOUTH WALLS; LEASE SPACE 6;
Misc
Corrective Action Required
12/29/2010
SILL PLATE ANCHORAGE AT CONCRETE FOUNDATION: CHECK ALL PLATES FOR ANCHOR BOLT INSTALLATION @ 4' O/C WITH MINIMUM 2 BOLTS PER PIECE
P305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
Corrective Action Required
01/07/2011
APPLY SHIELD PLATES TO PROTECT PVC PLUMBING PIPING FROM PENETRATION WHEREVER LESS THAN 1-1/2" FROM FACE OF FRAMING.
B717.2 Fireblocking
Corrective Action Required
01/07/2011
CONCEALED SPACES. In combustible construction, fireblocking shall be installed to cut off concealed draft openings (both vertical and horizontal) and shall form an effective barrier between floors, between a top story and a roof or attic space. Fireblocking shall be installed in the locations specified in Sections 717.2.2 through 717.2.7.
Misc
Corrective Action Required
01/07/2011
ELIMINATE CHOKING OF RESTROOM EXHAUST FAN DUCT AT BOTTOM CHORD OF TRUSSES.
Rough Framing Inspection - Commercial Partial 12/29/2010 at 12:00 AM 12/29/2010
Misc
Partial Correction
11/24/2010
SETTING OF EPOXY-SET SILL PLATE ANCHOR BOLTS YET TO BE COMPLETED.
Misc
Resolved
12/29/2010
REQUESTED INSPECTION OF ROOF SHEATHING NOT READY FOR INSPECTION: LADDER(S) NOT IN PLACE TO CLERSTORY ROOF
Misc
Corrective Action Required
11/24/2010
JACK TRUSSES AT CLERSTORY ROOF STRUCTURE: CONFIRM ABSENCE OF HANGERS ON SECONDARY TRUSSES
Above Ceiling Inspection Partial 1/7/2011 at 12:00 AM 01/07/2011
Misc
Partial Correction
01/07/2011
OK TO INSTALL GWB HARD LID AT BOTTOM CHORD OF TRUSSES
In-wall Inspection Partial 1/7/2011 at 12:00 AM 01/07/2011
Misc
Partial Correction
12/29/2010
OK TO COVER WHEN READY FRAMING AND IN-WALL SYSTEMS AT FOLLOWING LOCAIONS: LEASE SPACE 2 NORTH WALL + SOUTH WALL EXCEPT ALONG STAIRWELL; LEASE SPACE 3 NORTH, WEST AND SOUTH WALLS; LEASE SPACE 6;
Misc
Corrective Action Required
12/29/2010
SILL PLATE ANCHORAGE AT CONCRETE FOUNDATION: CHECK ALL PLATES FOR ANCHOR BOLT INSTALLATION @ 4' O/C WITH MINIMUM 2 BOLTS PER PIECE
In-wall Inspection Partial 1/14/2011 at 12:00 AM 01/14/2011
Misc
Partial Correction
01/07/2011
OK TO COVER WHEN READY FRAMING AND IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: LEASE SPACE 2 NORTH WALL + SOUTH WALL EXCEPT ALONG STAIRWELL; LEASE SPACE 3 NORTH, WEST AND SOUTH WALLS; LEASE SPACE 6;
Misc
Carried Forward
01/14/2011
SILL PLATE ANCHORAGE AT CONCRETE FOUNDATION: CHECK ALL ANCHOR BOLTS; EACH TO HAVE WASHER IN PLACE AND TO HAVE NUT TIGHTENED
Misc
Corrective Action Required
01/14/2011
PVC DWV PLUMING PIPE MUST BE PROTECTED WITH CODE-COMPLIANT SHIELD PLATE WHEREVER SURFACE OF PIPE IS LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE GWB OR OTHER WALL COVERING
Misc
Corrective Action Required
01/14/2011
FIRE-BLOCKING: SEAL ALL OPEINGS IN TOP PLATES AND ALL BORES OF STUDS BOUNDING IN-WALL RETURN AIR PLENUMS
Misc
Corrective Action Required
01/14/2011
SILL PLATE ANCHORAGE AT CONCRETE FOUNDATION: CHECK ALL ANCHOR BOLTS; EACH TO HAVE WASHER IN PLACE AND TO HAVE NUT TIGHTENED
In-wall Inspection Partial 1/18/2011 at 12:00 AM 01/18/2011
Misc
Partial Correction
01/14/2011
OK TO COVER WHEN READY FRAMING AND IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: LEASE SPACE 2 NORTH WALL + SOUTH WALL EXCEPT ALONG STAIRWELL; LEASE SPACE 3 NORTH, WEST AND SOUTH WALLS; LEASE SPACE 6; HALLAM 1ST FLR SPACE EXCEPT AT LOCATIONS AFFECTED BY ISSUES PRINTED BELOW
Misc
Resolved
01/18/2011
PVC DWV PLUMING PIPE MUST BE PROTECTED WITH CODE-COMPLIANT SHIELD PLATE WHEREVER SURFACE OF PIPE IS LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE GWB OR OTHER WALL COVERING
Misc
Corrective Action Required
01/14/2011
FIRE-BLOCKING: FIRE-SEAL TOP PLATE BORE AT WOMEN'S RR NORTH WALL
Misc
Corrective Action Required
01/18/2011
INSTALLATION OF SIMPSON STRONGWALL PANELS: PROVIDE FOURTEEN SDS 1/4" x 3-1/2" SCREWS AT TOP OF EACH PANEL AS INDICATED ON AFFIXED STICKER; ENSURE ALL ANCHOR BOLTS HAVE WASHERS INSTALLED AND NUTS TIGHTENED -- EXAMPLE: FUTURE OFFICE SE CORNER
Misc
Corrective Action Required
01/18/2011
ROOF TRUSSES @ RECEPTION/WAITING: ENSURE HANGERS ARE PROVIDED AT ALL TRUSSES DETERMINED PER CONSULTATION WITH STRUCTURAL ENGINEER.
All Rough Inspection - Commercial Passed 3/1/2011 at 12:00 AM 03/01/2011
Misc
Resolved
03/01/2011
INSTALLATION OF SIMPSON STRONGWALL PANELS: IN PROGRESS
Rough Framing Inspection - Commercial Passed 3/1/2011 at 12:00 AM 03/01/2011
Misc
Resolved
03/01/2011
SETTING OF EPOXY-SET SILL PLATE ANCHOR BOLTS YET TO BE COMPLETED.
Misc
Resolved
03/01/2011
JACK TRUSSES AT CLERSTORY ROOF STRUCTURE: CONFIRM ABSENCE OF HANGERS ON SECONDARY TRUSSES
In-wall Inspection Passed 3/28/2011 at 12:00 AM 03/01/2011
Misc
Resolved
03/01/2011
OK TO COVER WHEN READY FRAMING AND IN-WALL SYSTEMS AT FOLLOWING LOCATIONS: LEASE SPACE 2 NORTH WALL + SOUTH WALL EXCEPT ALONG STAIRWELL; LEASE SPACE 3 NORTH, WEST AND SOUTH WALLS; LEASE SPACE 6; HALLAM 1ST FLR SPACE EXCEPT AT LOCATIONS AFFECTED BY ISSUES PRINTED BELOW
Misc
Resolved
03/01/2011
FIRE-BLOCKING: FIRE-SEAL TOP PLATE BORE AT WOMEN'S RR NORTH WALL
Misc
Resolved
03/01/2011
INSTALLATION OF SIMPSON STRONGWALL PANELS: PROVIDE FOURTEEN SDS 1/4" x 3-1/2" SCREWS AT TOP OF EACH PANEL AS INDICATED ON AFFIXED STICKER; ENSURE ALL ANCHOR BOLTS HAVE WASHERS INSTALLED AND NUTS TIGHTENED -- EXAMPLE: FUTURE OFFICE SE CORNER
Misc
Resolved
03/01/2011
ROOF TRUSSES @ RECEPTION/WAITING: ENSURE HANGERS ARE PROVIDED AT ALL TRUSSES DETERMINED PER CONSULTATION WITH STRUCTURAL ENGINEER.
Occupancy Inspection - Fire Not Ready 03/15/2011
Misc
Corrective Action Required
03/15/2011
POST THE ADDRESS ABOVE THE EXTERIOR DOORS OF THE SUITES 4' MINIMUM, CONTRASTING COLOR WITH THE BACKGROUND
Misc
Corrective Action Required
03/15/2011
SECURE, CAP, ALL LOOSE WIRING INSIDE AND OUTSIDE J-BOXES, COVER OPEN J-BOXES, ALL ON THE INTERIOR AND EXTERIOR OF THE BUILDING.
Misc
Corrective Action Required
03/15/2011
INSTALL THE EMERGENCY EGRSS LIGHTING ON THE EXTERIOR OF THE EXITS.
Occupancy Inspection - Fire Not Ready 03/15/2011
Misc
Corrective Action Required
03/15/2011
POST THE ADDRESS ABOVE THE EXTERIOR DOORS OF THE SUITES 4' MINIMUM, CONTRASTING COLOR WITH THE BACKGROUND
Misc
Corrective Action Required
03/15/2011
SECURE, CAP, ALL LOOSE WIRING INSIDE AND OUTSIDE J-BOXES, COVER OPEN J-BOXES, ALL ON THE INTERIOR AND EXTERIOR OF THE BUILDING.
Misc
Corrective Action Required
03/15/2011
INSTALL THE EMERGENCY EGRSS LIGHTING ON THE EXTERIOR OF THE EXITS.
Misc
Corrective Action Required
03/15/2011
MOUNT FIRE EXTINGUISHERS IN LOCATIONS AS PER PLANS, 2A-10BC MINIMUM SIZE
Occupancy Inspection - Planning Not Ready 3/15/2011 at 12:00 AM 03/15/2011
Occupancy Inspection - Water Utilities Passed 3/15/2011 at 12:00 AM 03/15/2011
Occupancy Inspection - Engineering Not Ready 3/15/2011 at 12:00 AM 03/15/2011
Above Ceiling Inspection Passed 3/15/2011 at 12:00 AM 03/15/2011
Misc
Resolved
03/15/2011
OK TO INSTALL GWB HARD LID AT BOTTOM CHORD OF TRUSSES
Occupancy Inspection - Codes Commercial Failed 3/15/2011 at 12:00 AM 03/15/2011
Misc
Corrective Action Required
03/15/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT > FIRE DEPARTMENT > PLANNING & DEVELOPMENT DEPARTMENT
Misc
Corrective Action Required
03/15/2011
COMPLETE WORK ON BUILDING EXTERIOR INCLUDING BUT NOT LIMITED TO: > ELECTRICAL BOXES AND DEVICES > ROOF DRAIN DOWNSPOUTS > PAINTING OF GASS PIPING ALL SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/15/2011
ELIMINATE LEAKS AT ROOF AND ELSEWHERE
Misc
Corrective Action Required
03/15/2011
AFFIX PERMANENT LABELS AT POINTS OF EACH ELECTRICAL SERVICE
Misc
Corrective Action Required
03/15/2011
COMPLETE ROOF COVERING AND ROOFTOP WORK; PROVIDE INSPECTION ACCESS TO ROOFTOP; PER IMC/IFGC PERMANENT LADDER REQUIRED IF TOP OF PARAPET IS MARE THAN 16' ABOVE GRADE.
Misc
Corrective Action Required
03/15/2011
LABELING OF BREAKER POSITIONS IN ELECTRICAL PANELS: IDENTIFY ALL BREAKERS -- SPECIFIC/CLEAR RE LOCATIONS/EQUIPMENT SERVED
Misc
Corrective Action Required
03/15/2011
BASEMENT NOT READY FOR INSPECTION
Misc
Corrective Action Required
03/15/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Corrective Action Required
03/15/2011
ALL ELECTRICAL PANELS MUST BE CLOSED; ALL LINE CURRENT BOXES MUST BE CLOSED
Misc
Corrective Action Required
03/15/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Corrective Action Required
03/15/2011
Misc
Corrective Action Required
03/15/2011
BORROWED LIGHT UNIT WITHIN 24" OF DOOR AT BASEMENT STORAGE ROOM APPARENTLY NOT SAFTEY GLAZED
Misc
Corrective Action Required
03/15/2011
ONE SUPPORT FOR GAS PIPE TO WATER HEATER NOT SECURED TO BASEMENT FLOOR.
Misc
Corrective Action Required
03/15/2011
WALL BASE AT RESTROOMS NOT INSTALLED.
Misc
Corrective Action Required
03/15/2011
WEAK NEUTRAL INDICATION ON SOME ELECTRICAL RECEPTACLES AT IFR OFFICE, CONFERENCE, RECEPTION -- CHECK ALL.
Misc
Partial Correction
03/15/2011
ELECTRICAL RECEPTACLE SERVING SUMP PUMP IS GFCI PROTECTED -- NOT REQUIRED IF SINGLE OUTLET RECEPTACLE IS UTILIZED.
Occupancy Inspection - Codes Commercial Failed 3/15/2011 at 12:00 AM 03/15/2011
Misc
Corrective Action Required
03/15/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT > FIRE DEPARTMENT > PLANNING & DEVELOPMENT DEPARTMENT
Misc
Corrective Action Required
03/15/2011
COMPLETE WORK ON BUILDING EXTERIOR INCLUDING BUT NOT LIMITED TO: > ELECTRICAL BOXES AND DEVICES > ROOF DRAIN DOWNSPOUTS > PAINTING OF GASS PIPING ALL SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/15/2011
ELIMINATE LEAKS AT ROOF AND ELSEWHERE
Misc
Corrective Action Required
03/15/2011
AFFIX PERMANENT LABELS AT POINTS OF EACH ELECTRICAL SERVICE
Misc
Corrective Action Required
03/15/2011
COMPLETE ROOF COVERING AND ROOFTOP WORK; PROVIDE INSPECTION ACCESS TO ROOFTOP; PER IMC/IFGC PERMANENT LADDER REQUIRED IF TOP OF PARAPET IS MORE THAN 16' ABOVE GRADE.
Misc
Corrective Action Required
03/15/2011
LABELING OF BREAKER POSITIONS IN ELECTRICAL PANELS: IDENTIFY ALL BREAKERS -- SPECIFIC/CLEAR RE LOCATIONS/EQUIPMENT SERVED
Misc
Corrective Action Required
03/15/2011
BASEMENT NOT READY FOR INSPECTION
Misc
Corrective Action Required
03/15/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Corrective Action Required
03/15/2011
ALL ELECTRICAL PANELS MUST BE CLOSED; ALL LINE CURRENT BOXES MUST BE CLOSED
Misc
Corrective Action Required
03/15/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Corrective Action Required
03/15/2011
Misc
Corrective Action Required
03/15/2011
BORROWED LIGHT UNIT WITHIN 24" OF DOOR AT BASEMENT STORAGE ROOM APPARENTLY NOT SAFTEY GLAZED
Misc
Corrective Action Required
03/15/2011
ONE SUPPORT FOR GAS PIPE TO WATER HEATER NOT SECURED TO BASEMENT FLOOR.
Misc
Corrective Action Required
03/15/2011
WALL BASE AT RESTROOMS NOT INSTALLED.
Misc
Corrective Action Required
03/15/2011
WEAK NEUTRAL INDICATION ON SOME ELECTRICAL RECEPTACLES AT IFR OFFICE, CONFERENCE, RECEPTION -- CHECK ALL.
Misc
Partial Correction
03/15/2011
ELECTRICAL RECEPTACLE SERVING SUMP PUMP IS GFCI PROTECTED -- NOT REQUIRED IF SINGLE OUTLET RECEPTACLE IS UTILIZED.
Occupancy Inspection - Codes Commercial Failed 3/16/2011 at 12:00 AM 03/16/2011
Misc
Corrective Action Required
03/15/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT > FIRE DEPARTMENT > PLANNING & DEVELOPMENT DEPARTMENT
Misc
Corrective Action Required
03/15/2011
COMPLETE WORK ON BUILDING EXTERIOR INCLUDING BUT NOT LIMITED TO: > ELECTRICAL BOXES AND DEVICES > ROOF DRAIN DOWNSPOUTS > PAINTING OF GASS PIPING ALL SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Corrective Action Required
03/15/2011
ELIMINATE LEAKS AT ROOF AND ELSEWHERE
Misc
Corrective Action Required
03/15/2011
AFFIX PERMANENT LABELS AT POINTS OF EACH ELECTRICAL SERVICE
Misc
Corrective Action Required
03/15/2011
COMPLETE ROOF COVERING AND ROOFTOP WORK; PROVIDE INSPECTION ACCESS TO ROOFTOP; PER IMC/IFGC PERMANENT LADDER REQUIRED IF TOP OF PARAPET IS MARE THAN 16' ABOVE GRADE.
Misc
Corrective Action Required
03/15/2011
LABELING OF BREAKER POSITIONS IN ELECTRICAL PANELS: IDENTIFY ALL BREAKERS -- SPECIFIC/CLEAR RE LOCATIONS/EQUIPMENT SERVED
Misc
Corrective Action Required
03/15/2011
BASEMENT NOT READY FOR INSPECTION
Misc
Corrective Action Required
03/15/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Corrective Action Required
03/15/2011
ALL ELECTRICAL PANELS MUST BE CLOSED; ALL LINE CURRENT BOXES MUST BE CLOSED
Misc
Corrective Action Required
03/15/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Corrective Action Required
03/15/2011
BORROWED LIGHT UNIT WITHIN 24" OF DOOR AT BASEMENT STORAGE ROOM APPARENTLY NOT SAFTEY GLAZED
Misc
Corrective Action Required
03/15/2011
ONE SUPPORT FOR GAS PIPE TO WATER HEATER NOT SECURED TO BASEMENT FLOOR.
Misc
Corrective Action Required
03/15/2011
WALL BASE AT RESTROOMS NOT INSTALLED.
Misc
Corrective Action Required
03/15/2011
WEAK NEUTRAL INDICATION ON SOME ELECTRICAL RECEPTACLES AT IFR OFFICE, CONFERENCE, RECEPTION -- CHECK ALL.
Misc
Partial Correction
03/15/2011
ELECTRICAL RECEPTACLE SERVING SUMP PUMP IS GFCI PROTECTED -- NOT REQUIRED IF SINGLE OUTLET RECEPTACLE IS UTILIZED.
Above Ceiling Inspection Failed 3/21/2011 at 12:00 AM 03/21/2011
Misc
Corrective Action Required
03/21/2011
ACT ABOVE-CEILING INSPECTION AT BASEMENT: LAY-IN LUMINAIRES REQUIRE SLACK WIRES
Misc
Corrective Action Required
03/21/2011
ACT ABOVE-CEILING INSPECTION AT BASEMENT: HVAC DUCT NEAR EAST WALL DICONTINUOUS
Misc
Corrective Action Required
03/21/2011
LOW VOLTAGE CONDUCTORS TO BE SECURED TO STRUCTURE WELL CLEAR OF ACT CEILING GRID
Occupancy Inspection - Codes Commercial Failed 3/24/2011 at 12:00 AM 03/24/2011
Misc
Corrective Action Required
03/16/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT > FIRE DEPARTMENT > PLANNING & DEVELOPMENT DEPARTMENT
Misc
Resolved
03/24/2011
COMPLETE WORK ON BUILDING EXTERIOR INCLUDING BUT NOT LIMITED TO: > ELECTRICAL BOXES AND DEVICES > ROOF DRAIN DOWNSPOUTS > PAINTING OF GASS PIPING ALL SUBJECT TO APPROVAL WHEN COMPLETED
Misc
Resolved
03/24/2011
ELIMINATE LEAKS AT ROOF AND ELSEWHERE
Misc
Resolved
03/24/2011
AFFIX PERMANENT LABELS AT POINTS OF EACH ELECTRICAL SERVICE
Misc
Corrective Action Required
03/16/2011
MINIMUM 42" HIGH ROOF EDGE GUARD IS REQUIRED WHERE ACCESS HATCH AND APPLIANCES REQUIRING SERVICING ARE LOCATED WITHIN 10' OF ROOF EDGE.
Misc
Corrective Action Required
03/16/2011
LABELING OF BREAKER POSITIONS IN ELECTRICAL PANELS: IDENTIFY ALL BREAKERS -- SPECIFIC / CLEAR RE LOCATIONS/EQUIPMENT SERVED
Misc
Resolved
03/24/2011
BASEMENT NOT READY FOR INSPECTION
Misc
Corrective Action Required
03/16/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Corrective Action Required
03/16/2011
ALL ELECTRICAL PANELS MUST BE CLOSED; ALL LINE CURRENT BOXES MUST BE CLOSED
Misc
Corrective Action Required
03/16/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Resolved
03/24/2011
BORROWED LIGHT UNIT WITHIN 24" OF DOOR AT BASEMENT STORAGE ROOM APPARENTLY NOT SAFTEY GLAZED
Misc
Resolved
03/24/2011
ONE SUPPORT FOR GAS PIPE TO WATER HEATER NOT SECURED TO BASEMENT FLOOR.
Misc
Resolved
03/24/2011
WALL BASE AT RESTROOMS NOT INSTALLED.
Misc
Resolved
03/24/2011
WEAK NEUTRAL INDICATION ON SOME ELECTRICAL RECEPTACLES AT IFR OFFICE, CONFERENCE, RECEPTION -- CHECK ALL.
Misc
Resolved
03/24/2011
ELECTRICAL RECEPTACLE SERVING SUMP PUMP IS GFCI PROTECTED -- NOT REQUIRED IF SINGLE OUTLET RECEPTACLE IS UTILIZED.
Misc
Corrective Action Required
03/24/2011
BUILD-OUT AND OCCUPANCY OF NE CORNER OF BASEMENT NOT REFLECTED ON DRAWINGS; SUBMIT REVISED DRAWINGS FOR REVIEW AND RECORD.
Misc
Corrective Action Required
03/24/2011
POWER CORD FOR SUMP PUMP MAY NOT BE PLUGGED INTO RECEPTACLE IN ANOTHER ROOM. RECEPT MUST BE LOCAL.
Misc
Corrective Action Required
03/24/2011
REQUIRED RECEPTACLE NOT FOUND WITHIN 25' OF ROOFTOP MECHANICAL UNIT.
Misc
Corrective Action Required
03/24/2011
ROOFTOP MECHANICAL UNITS MUST BE DESIGNATED (ALPHA/NUMERIC) AND THAT DESIGNATION MUST BE REFLECTED AT ELECTRICAL SERVICE PANEL.
Misc
Corrective Action Required
03/24/2011
SOME ROOFTOP SCUPPER OPENINGS ARE NOT CLEAR FOR WATER PASSAGE.
Misc
Corrective Action Required
03/24/2011
AFTER ALL ROOFTOP WORK IS COMPLETED LEAVE ROOF SURFACE CLEAN AND CLEAR OF ALL UNUSED MATERIAL AND DEBRIS -- ESPECIALLY METAL
Misc
Corrective Action Required
03/24/2011
SEAL ALL OPENINGS AND PENETRATIONS AT EXTERIOR WALLS. EXAMPLE: PIPING PENETRATIONS AT NORTHEAST CORNER
Occupancy Inspection - Fire Temporary C of O 03/25/2011
Misc
Corrective Action Required
03/15/2011
POST THE ADDRESS ABOVE THE EXTERIOR DOORS OF THE SUITES 4' MINIMUM, CONTRASTING COLOR WITH THE BACKGROUND
Misc
Corrective Action Required
03/15/2011
SECURE, CAP, ALL LOOSE WIRING INSIDE AND OUTSIDE J-BOXES, COVER OPEN J-BOXES, ALL ON THE INTERIOR AND EXTERIOR OF THE BUILDING.
Misc
Corrective Action Required
03/15/2011
INSTALL THE EMERGENCY EGRSS LIGHTING ON THE EXTERIOR OF THE EXITS.
Misc
Corrective Action Required
03/15/2011
MOUNT FIRE EXTINGUISHERS IN LOCATIONS AS PER PLANS, 2A-10BC MINIMUM SIZE.
Occupancy Inspection - Fire Passed 3/28/2011 at 12:00 AM 03/28/2011
Misc
Corrective Action Required
03/28/2011
POST THE ADDRESS ABOVE THE EXTERIOR DOORS OF THE SUITES 4' MINIMUM, CONTRASTING COLOR WITH THE BACKGROUND
Misc
Corrective Action Required
03/28/2011
SECURE, CAP, ALL LOOSE WIRING INSIDE AND OUTSIDE J-BOXES, COVER OPEN J-BOXES, ALL ON THE INTERIOR AND EXTERIOR OF THE BUILDING.
Misc
Corrective Action Required
03/28/2011
INSTALL THE EMERGENCY EGRSS LIGHTING ON THE EXTERIOR OF THE EXITS.
Misc
Corrective Action Required
03/28/2011
MOUNT FIRE EXTINGUISHERS IN LOCATIONS AS PER PLANS, 2A-10BC MINIMUM SIZE.
Above Ceiling Inspection Passed 3/28/2011 at 12:00 AM 03/28/2011
Misc
Resolved
03/28/2011
ACT ABOVE-CEILING INSPECTION AT BASEMENT: LAY-IN LUMINAIRES REQUIRE SLACK WIRES
Misc
Resolved
03/28/2011
ACT ABOVE-CEILING INSPECTION AT BASEMENT: HVAC DUCT NEAR EAST WALL DICONTINUOUS
Misc
Resolved
03/28/2011
LOW VOLTAGE CONDUCTORS TO BE SECURED TO STRUCTURE WELL CLEAR OF ACT CEILING GRID
Electrical Service Inspection Passed 3/28/2011 at 12:00 AM 03/28/2011
Gas Piping Inspection - Commercial Passed 3/28/2011 at 12:00 AM 03/28/2011
Gas Service Inspection - Commercial Passed 3/28/2011 at 12:00 AM 03/28/2011
Occupancy Inspection - Codes Commercial Temporary C of O 3/28/2011 at 12:00 AM 03/28/2011
Misc
Corrective Action Required
03/24/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT > PLANNING & DEVELOPMENT DEPARTMENT
Misc
Resolved
03/28/2011
MINIMUM 42" HIGH ROOF EDGE GUARD IS REQUIRED WHERE ACCESS HATCH AND APPLIANCES REQUIRING SERVICING ARE LOCATED WITHIN 10' OF ROOF EDGE.
Misc
Resolved
03/28/2011
LABELING OF BREAKER POSITIONS IN ELECTRICAL PANELS: IDENTIFY ALL BREAKERS -- SPECIFIC / CLEAR RE LOCATIONS/EQUIPMENT SERVED
Misc
Resolved
05/20/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Resolved
03/28/2011
ALL ELECTRICAL PANELS MUST BE CLOSED; ALL LINE CURRENT BOXES MUST BE CLOSED
Misc
Corrective Action Required
03/24/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Resolved
05/20/2011
BUILD-OUT AND OCCUPANCY OF NE CORNER OF BASEMENT NOT REFLECTED ON DRAWINGS; SUBMIT REVISED DRAWINGS FOR REVIEW AND RECORD.
Misc
Resolved
03/28/2011
POWER CORD FOR SUMP PUMP MAY NOT BE PLUGGED INTO RECEPTACLE IN ANOTHER ROOM. RECEPT MUST BE LOCAL.
Misc
Corrective Action Required
03/24/2011
REQUIRED RECEPTACLE NOT FOUND WITHIN 25' OF ROOFTOP MECHANICAL UNIT.
Misc
Resolved
03/28/2011
ROOFTOP MECHANICAL UNITS MUST BE DESIGNATED (ALPHA/NUMERIC) AND THAT DESIGNATION MUST BE REFLECTED AT ELECTRICAL SERVICE PANEL.
Misc
Resolved
03/28/2011
SOME ROOFTOP SCUPPER OPENINGS ARE NOT CLEAR FOR WATER PASSAGE.
Misc
Corrective Action Required
03/24/2011
AFTER ALL ROOFTOP WORK IS COMPLETED LEAVE ROOF SURFACE CLEAN AND CLEAR OF ALL UNUSED MATERIAL AND DEBRIS -- ESPECIALLY METAL
Occupancy Inspection - Planning Temporary C of O 3/24/2011 at 2:30 AM 03/31/2011
Corrective Action Required
03/28/2011
All landscaping, sod, and seeding shall be installed by May 31st, 2011. Once completed a re-inspection shall be required.
Corrective Action Required
03/28/2011
Once the lighting has been installed, a re-inspection shall be required.
Corrective Action Required
03/28/2011
The gates to the trash enclosure shall be installed, once completed a re-inspection shall be required.
Corrective Action Required
03/28/2011
Once Phase 2 is completed a re-inspection shall be required.
Underground Electrical Inspection - Commercial Passed 4/6/2011 4/6/2011 at 12:00 AM 04/06/2011
Occupancy Inspection - Planning Passed 5/20/2011 at 12:00 AM 05/20/2011
Rough Framing Inspection - Commercial Passed 5/27/2011 at 12:00 AM 05/27/2011
Misc
Resolved
03/01/2011
SETTING OF EPOXY-SET SILL PLATE ANCHOR BOLTS YET TO BE COMPLETED.
Misc
Resolved
03/01/2011
JACK TRUSSES AT CLERSTORY ROOF STRUCTURE: CONFIRM ABSENCE OF HANGERS ON SECONDARY TRUSSES
Occupancy Inspection - Codes Commercial Full C of O 5/27/2011 at 12:00 AM 05/27/2011
Misc
Corrective Action Required
03/28/2011
RESOLVE ISSUES WITH OTHER DEPARTMENTS: > PUBLIC WORKS DEPARTMENT
Misc
Resolved
05/06/2011
VAPOR RETARDER AT INSULATION IN LEASE SPACES 2 & 3 IS FLAMABLE PAPER (SEE WARNING ON FACE) -- MAY NOT BE LEFT EXPOSED.
Misc
Resolved
05/06/2011
BOCA PLATES NOT INSTALLED BEFORE WALL SHEATHING AT SILL PLATE @ NE CORNER OF LEASE SPACE 3.
Misc
Resolved
05/06/2011
BUILD-OUT AND OCCUPANCY OF NE CORNER OF BASEMENT NOT REFLECTED ON DRAWINGS; SUBMIT REVISED DRAWINGS FOR REVIEW AND RECORD.
Misc
Resolved
05/06/2011
REQUIRED RECEPTACLE NOT FOUND WITHIN 25' OF ROOFTOP MECHANICAL UNIT.
Misc
Resolved
05/06/2011
AFTER ALL ROOFTOP WORK IS COMPLETED LEAVE ROOF SURFACE CLEAN AND CLEAR OF ALL UNUSED MATERIAL AND DEBRIS -- ESPECIALLY METAL
Occupancy Inspection - Planning Passed 3/28/2011 at 12:00 AM 11/01/2013
Documents & Images
Date Uploaded File Type Document Name
11/08/2010 Letter Plan Review Conditions
11/15/2010 Letter Building Permit
11/22/2010 Letter Inspection Summary
11/23/2010 Letter Inspection Summary
12/21/2010 Letter Inspection Summary
12/29/2010 Letter Inspection Summary
01/07/2011 Letter Inspection Summary
01/14/2011 Letter Inspection Summary
01/18/2011 Letter Inspection Summary
03/15/2011 Letter Inspection Summary
03/15/2011 Letter Inspection Summary
03/16/2011 Letter Inspection Summary
03/21/2011 Letter Inspection Summary
03/24/2011 Letter Inspection Summary
03/28/2011 Letter Fire Loss Reduction Form
03/28/2011 Letter Temporary Certificate of Occupancy
03/31/2011 Letter Planning Inspection Summary
04/06/2011 Letter Inspection Summary
05/27/2011 Letter Field Certificate of Occupancy
06/03/2011 Letter Final Certificate of Occupancy
06/03/2011 Letter Final Certificate of Occupancy
06/21/2013 Letter Fire Loss Reduction Form
06/27/2013 Letter Fire Loss Reduction Form
06/27/2013 Letter Fire Loss Reduction Form
06/27/2013 Letter Plan Review Conditions
08/21/2013 Letter Inspection Summary
05/23/2018 Activity Document B1001246hallamofficebuildingcomments1
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home