Permit Application Status

B1001108


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1001108
Building Permit - Commercial
Final Completion
PARTIAL COMMERCIAL
This permit is for the foundation, underslab, water and sewer only.
09/09/2010
09/14/2010
04/26/2011
04/08/2011
Locations
Contacts
CL HOWERTON ENTERPRISES, Address:40303 E 150TH ST  
E & Q HEATING AND COOLING, Address:5 SW 4TH ST  
INTEGRAL CONSTRUCTION SERVICES, INC., Address:303 SW MARKET  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 03/12/2011 10/29/2010
Correction

Codes Administration - This is an "at risk permit". Construction shall be in accordance with plans submitted for permit approval. The applicant understands that issuance of this permit does not guaranty issuance of a full permit.
Correction

Codes Administration - This project has not bee reviewed for code compliance as an analysis was not provided as part of the application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $63.92 $63.92 Paid 09/14/2010
84 Water Meters $458.91 $458.91 Paid 09/14/2010
85 Water Taps $7,984.00 $7,984.00 Paid 09/14/2010
Right of Way Permit $60.00 $60.00 Paid 09/14/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Not Ready 09/29/2010
Correction
Partial Correction
09/29/2010
COURTESY STOP FOOTING LAYOUT JUST BEGINNING; NOT READY FOR INSPECTION. OBSERVED FOOTING PREP DISCUSSED INSP POINTS
Footing Inspection - Commercial Partial 09/30/2010
Correction
Resolved
09/30/2010
COURTESY STOP 9/29/2010
Correction
Partial Correction
09/30/2010
PREP TO POUR WALL FOOTINGS ALL AT BASEMENT LEVEL; OK TO POUR WHEN READY FOLLOWING SEGMENTS:
Concrete Walls and Columns Inspection Not Ready 10/05/2010
Correction
Corrective Action Required
10/05/2010
PREPARATION TO POUR BASEMENT WALLS
Footing Inspection - Commercial Partial 10/06/2010
Correction
Partial Correction
10/06/2010
PREP TO POUR WALL FOOTINGS BASEMENT LEVEL: EAST, NORTH, SOUTH WALLS; WEST WALL OK TO POUR WHEN READY FOLLOWING SEGMENTS:
Concrete Walls and Columns Inspection Passed 10/06/2010
Correction
Resolved
10/06/2010
PREPARATION TO POUR BASEMENT WALLS OK TO POUR WHEN READY
Underslab Plumbing Inspection - Commercial Partial 12/3/2010 10/14/2010
Correction
Partial Correction
10/14/2010
UNDER-SLAB SANITARY WASTE, SOIL, VENT PIPING OK TO COVER WHEN READY UNDER BASEMENT SLAB
Footing Inspection - Commercial Partial 10/20/2010
Correction
Resolved
10/20/2010
PREP TO POUR WALL FOOTINGS BASEMENT LEVEL
Correction
Partial Correction
10/20/2010
PREPARATION TO POUR GROUND LEVEL GRADE BEAMS FROM CORNER DETAIL A/S1 NORTH THEN WEST TO 2' EAST OF DETAIL C/S1; FROM CORNER DETAIL B/S1 TO F/S1 THEN WEST TO 2' EAST OF E/S1; OK TO POUR WHEN READY SECTIONS DESCRIBED BELOW:
Footing Inspection - Commercial Passed 10/21/2010
Correction
Resolved
10/21/2010
PREPARATION TO POUR GROUND LEVEL GRADE BEAMS FROM CORNER DETAIL A/S1 NORTH THEN WEST TO 2' EAST OF DETAIL C/S1; FROM CORNER DETAIL B/S1 TO F/S1 THEN WEST TO 2' EAST OF E/S1; 2' EAST OF CORNER DETAIL C/S1 TO 2' EAST OF E/S1 TO COMPLETE PERIMETER OK TO POUR WHEN READY SECTIONS DESCRIBED BELOW:
Underslab Plumbing Inspection - Commercial Partial 10/29/2010
Correction
Partial Correction
10/29/2010
UNDER-SLAB SANITARY WASTE, SOIL, VENT PIPING ALL UNDER BASEMENT SLAB; GROUND LEVEL 4" PVC N-S TRUNK LINE SOUTH 38'; OK TO COVER WHEN READY
Underslab Plumbing Inspection - Commercial Passed 11/2/2010 at 12:00 AM 11/02/2010
Correction
Resolved
11/02/2010
Sewer Service Inspection Partial 11/10/2010
Misc
Partial Correction
11/10/2010
SANITARY SERVICE PIPING OK TO COVER FOLLOWING SEGMENTS: FROM BUILDING ENTRY TO 70' WEST;
Underground Electrical Inspection - Commercial Failed 11/30/2010 at 12:00 AM 11/30/2010
Misc
Corrective Action Required
11/30/2010
- UNDERGROUND ELECTRICAL - FROM PROPERTY LINE TO BUILDING - 3 LINES OF 2 1/2" PVC - STACKED - TOP ROW OF PVC INSUFFICIENT DEPTH - ENCASE IN CONCRETE - LEAVE ENTIRE LENGTH OPEN FOR INSPECTION OF CONCRETE ENCASEMENT.
Sewer Service Inspection Partial 12/3/2010 at 12:00 AM 12/03/2010
Misc
Partial Correction
12/03/2010
OK TO COVER WHEN READY: 4' PVC SANITARY SEWER LINE COMPLETE FROM BUILDING ENTRY TO 66' W OF W FACE OF BUILDING;
Water Service Inspection Partial 12/3/2010 at 12:00 AM 12/03/2010
Misc
Partial Correction
12/03/2010
OK TO COVER WHEN READY: 1" TYPE K COPPER WATER LINE COMPLETE FROM BUILDING ENTRY TO 66' W OF W FACE OF BUILDING;
Underground Electrical Inspection - Commercial Partial 12/9/2010 at 12:00 AM 12/09/2010
Misc
Corrective Action Required
11/30/2010
- UNDERGROUND ELECTRICAL - FROM PROPERTY LINE TO BUILDING - 3 LINES OF 2 1/2" PVC - STACKED - TOP ROW OF PVC INSUFFICIENT DEPTH - ENCASE IN CONCRETE - LEAVE ENTIRE LENGTH OPEN FOR INSPECTION OF CONCRETE ENCASEMENT.
Misc
Partial Correction
12/09/2010
-UNDERGROUND CONDUITS FROM BUILDING TO 2 LIGHT POLES-OK CONDUITS IN SAME TRENCH AS SEWER&STORM WATER. NEED INSPECTION FOR SEWER&STORM (BILL LYON) WHEN READY. CONTINUE BORING THROUGH STREET TO SIGN WILL BE INSPECTED AT LATER DATE.
Sewer Service Inspection Partial 12/9/2010 at 12:00 AM 12/09/2010
Misc
Partial Correction
12/03/2010
SANITARY SERVICE PIPING OK TO COVER FOLLOWING SEGMENTS: FROM BUILDING ENTRY TO INSERTED TEE (TO BE INSPECTED BY BILL LYON);
Water Service Inspection Partial 12/9/2010 at 12:00 AM 12/09/2010
Misc
Partial Correction
12/03/2010
OK TO COVER WHEN READY: 1" TYPE K COPPER WATER LINE COMPLETE FROM BUILDING ENTRY TO WEST SIDE OF STREET
Underground Electrical Inspection - Commercial Partial 12/9/2010 at 12:00 AM 12/09/2010
Misc
Partial Correction
12/09/2010
- UNDERGROUND SECONDARY SERVICE POWER LINES FROM PROPERTY LINE TO BUILDING-OK
Misc
Partial Correction
12/09/2010
-UNDERGROUND CONDUITS FROM BUILDING TO 2 LIGHT POLES AND ONE ACROSS STREET TO SIGN-OK
In-wall Inspection Failed 1/24/2011 at 12:00 AM 01/24/2011
Misc
Partial Correction
01/24/2011
WALL FRAMING & IN-WALL SYSTEMS AT SE LEASE SPACE: OK TO INSULATED WALLS AT EAST SPACES
Misc
Corrective Action Required
01/24/2011
HEADER BEARING: ELIMINATE GAPS AT BEARING SURFACES BETWEEN WINDOW AND DOOR HEADERS TO JACK STUDS
Misc
Corrective Action Required
01/24/2011
REINFORCE TOP PLATES OVER-BORED FOR PENETRATION BY ELECTRICAL FEEDER CABLES
Misc
Corrective Action Required
01/24/2011
PROTECT ELECTRICAL FEEDER CABLES FROM PENETRATION WHERE THEY PASS THROUGH TOP WALL PLATES
Misc
Corrective Action Required
01/24/2011
INSTALL STUD SHOES TO REINFORCE OVER-BORED STUDS WHERE BORED FOR PASSAGE OF PVC PLUMBING PIPE
Misc
Corrective Action Required
01/24/2011
TOP OF MECHANICAL SHAFT NEAR STAIRWELL NOT FIRE-BLOCKED
Misc
Corrective Action Required
01/24/2011
LEVEL-TO-LEVEL FIRE-BLOCKING: COMPLETE SEALING OF ALL BORES AND OTHER OPENINGS IN TOP AND BOTTOM PLATES
Electrical Service Inspection Failed 1/24/2011 at 12:00 AM 01/24/2011
Misc
Corrective Action Required
01/24/2011
ELECTRICAL SERVICE FEEDERS: APPROVED DRAWINGS REQUIRE COPPER CONDUCTORS IN 2" CONDUIT -- ALUMINUM CABLES ACTUALLY INSTALLED
Above Ceiling Inspection Partial 1/24/2011 at 12:00 AM 01/24/2011
Misc
Partial Correction
01/24/2011
SYSTEMS ABOVE TRUSS BOTTOM CHORDS: NO REMAINING ISSUES
Electrical Service Inspection Passed 1/26/2011 at 12:00 AM 01/26/2011
Misc
Resolved
01/26/2011
ELECTRICAL SERVICE FEEDERS: APPROVED DRAWINGS REQUIRE COPPER CONDUCTORS IN 2" CONDUIT -- ALUMINUM CABLES ACTUALLY INSTALLED. OK PER ENGINEER LETTER DTD 1/25/11
Gas Service Inspection - Commercial Partial 2/8/2011 at 12:00 AM 02/08/2011
Misc
Partial Correction
02/08/2011
VISUAL INSPECTION AND PRESSURE TEST ON GAS SERVICE FOR SUITE "A" APPROVED -- RELEASE SERVICE
In-wall Inspection Partial 2/8/2011 at 12:00 AM 02/08/2011
Misc
Partial Correction
01/24/2011
WALL FRAMING & IN-WALL SYSTEMS AT SE LEASE SPACE: OK TO INSULATE WALLS AT EAST SPACES
Misc
Resolved
02/08/2011
HEADER BEARING: ELIMINATE GAPS AT BEARING SURFACES BETWEEN WINDOW AND DOOR HEADERS TO JACK STUDS
Misc
Corrective Action Required
01/24/2011
REINFORCE TOP PLATES OVER-BORED FOR PENETRATION BY ELECTRICAL FEEDER CABLES
Misc
Corrective Action Required
01/24/2011
PROTECT ELECTRICAL FEEDER CABLES FROM PENETRATION WHERE THEY PASS THROUGH TOP WALL PLATES
Misc
Corrective Action Required
01/24/2011
INSTALL STUD SHOES TO REINFORCE OVER-BORED STUDS WHERE BORED FOR PASSAGE OF PVC PLUMBING PIPE
Misc
Corrective Action Required
01/24/2011
TOP OF MECHANICAL SHAFT NEAR STAIRWELL NOT FIRE-BLOCKED
Misc
Corrective Action Required
01/24/2011
LEVEL-TO-LEVEL FIRE-BLOCKING: COMPLETE SEALING OF ALL BORES AND OTHER OPENINGS IN TOP AND BOTTOM PLATES
In-wall Inspection Failed 2/16/2011 at 12:00 AM 02/16/2011
Misc
Resolved
02/16/2011
WALL FRAMING & IN-WALL SYSTEMS AT SE LEASE SPACE: FIRE-BLOCK ALL OPENINGS IN TOP AND BOTTOM PLATES
Misc
Resolved
02/16/2011
REINFORCE TOP PLATES OVER-BORED FOR PENETRATION BY ELECTRICAL FEEDER CABLES
Misc
Resolved
02/16/2011
PROTECT ELECTRICAL FEEDER CABLES FROM PENETRATION WHERE THEY PASS THROUGH TOP WALL PLATES
Misc
Resolved
02/16/2011
INSTALL STUD SHOES TO REINFORCE OVER-BORED STUDS WHERE BORED FOR PASSAGE OF PVC PLUMBING PIPE
Misc
Resolved
02/16/2011
Misc
Corrective Action Required
02/08/2011
AT SE (CHIROPRACTOR) LEASE SUITE: 1) COMPLETE SEALING OF ALL BORES AND OTHER OPENINGS IN TOP AND BOTTOM PLATES 2) TOP OF MECHANICAL SHAFT ADJACENT TO STAIRWELL NOT FIRE-BLOCKED
Misc
Corrective Action Required
02/16/2011
AT BASEMENT SPACES TO BE FINISHED: FIREBLOCK 1) TOP OF EXTERIOR STUD WALLS NOT TIGHT TO CONCRETE WALL AND HORIZONTALLY AT 10' INTERVALS 2) ALL BORES AND OPENINGS IN TOP PLATES 3) BORES AND OPENINGS IN STUDS BOUNDING RETURN AIR WALL PLENUMS
In-wall Inspection Passed 2/18/2011 at 12:00 AM 02/18/2011
Misc
Resolved
02/18/2011
AT SE (CHIROPRACTOR) LEASE SUITE: 1) COMPLETE SEALING OF ALL BORES AND OTHER OPENINGS IN TOP AND BOTTOM PLATES 2) TOP OF MECHANICAL SHAFT ADJACENT TO STAIRWELL NOT FIRE-BLOCKED
Misc
Resolved
02/18/2011
AT BASEMENT SPACES TO BE FINISHED: FIREBLOCK 1) TOP OF EXTERIOR STUD WALLS NOT TIGHT TO CONCRETE WALL AND HORIZONTALLY AT 10' INTERVALS 2) ALL BORES AND OPENINGS IN TOP PLATES 3) BORES AND OPENINGS IN STUDS BOUNDING RETURN AIR WALL PLENUMS
Above Ceiling Inspection Partial 3/3/2011 at 12:00 AM 03/03/2011
Misc
Resolved
03/03/2011
SYSTEMS ABOVE TRUSS BOTTOM CHORDS: NO REMAINING ISSUES
Misc
Corrective Action Required
03/03/2011
ACT CEILING FRAMING & ABOVE-CEILING SYSTEMS OK TO COVER EXCEPT 1) LEAVE OUT TWO TILES IN FUTURE OFFICE BELOW OPEN ELECT J.B.s AND 2) TWO TILES AT ENTRANCE VESTIBULE BELOW UNTERMINATED NMB CABLE AND ITS DESTINATION.
Water Service Inspection Passed 12/9/2010 at 12:00 AM 03/16/2011
Misc
Partial Correction
12/09/2010
OK TO COVER WHEN READY: 1" TYPE K COPPER WATER LINE COMPLETE FROM BUILDING ENTRY TO WEST SIDE OF STREET
Above Ceiling Inspection Passed 3/3/2011 at 12:00 AM 03/16/2011
Misc
Corrective Action Required
03/03/2011
ACT CEILING FRAMING & ABOVE-CEILING SYSTEMS OK TO COVER EXCEPT 1) LEAVE OUT TWO TILES IN FUTURE OFFICE BELOW OPEN ELECT J.B.s AND 2) TWO TILES AT ENTRANCE VESTIBULE BELOW UNTERMINATED NMB CABLE AND ITS DESTINATION.
Gas Service Inspection - Commercial Passed 2/8/2011 at 12:00 AM 03/16/2011
Misc
Partial Correction
02/08/2011
VISUAL INSPECTION AND PRESSURE TEST ON GAS SERVICE FOR SUITE "A" APPROVED -- RELEASE SERVICE
Sewer Service Inspection Passed 12/9/2010 at 12:00 AM 03/16/2011
Misc
Partial Correction
12/09/2010
SANITARY SERVICE PIPING OK TO COVER FOLLOWING SEGMENTS: FROM BUILDING ENTRY TO INSERTED TEE (TO BE INSPECTED BY BILL LYON);
Underground Electrical Inspection - Commercial Passed 12/9/2010 at 12:00 AM 03/16/2011
Misc
Partial Correction
12/09/2010
- UNDERGROUND SECONDARY SERVICE POWER LINES FROM PROPERTY LINE TO BUILDING-OK
Misc
Partial Correction
12/09/2010
-UNDERGROUND CONDUITS FROM BUILDING TO 2 LIGHT POLES AND ONE ACROSS STREET TO SIGN-OK
Underslab Plumbing Inspection - Commercial Passed 3/29/2011 at 12:00 AM 03/29/2011
Final Inspection - Commercial Passed 3/29/2011 at 12:00 AM 03/29/2011
Documents & Images
Date Uploaded File Type Document Name
11/02/2010 Letter Inspection Summary
11/04/2010 Letter Inspection Summary
11/09/2010 Letter Inspection Summary
11/10/2010 Letter Inspection Summary
11/30/2010 Letter Inspection Summary
12/03/2010 Letter Inspection Summary
12/09/2010 Letter Inspection Summary
12/09/2010 Letter Inspection Summary
01/24/2011 Letter Inspection Summary
01/26/2011 Letter Inspection Summary
01/26/2011 Letter Inspection Summary
02/08/2011 Letter Inspection Summary
02/16/2011 Letter Inspection Summary
02/18/2011 Letter Inspection Summary
03/03/2011 Letter Inspection Summary
03/29/2011 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home