Permit Application Status

B1000971


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1000971
Building Permit - Commercial
Final Completion
NEW OTHER
LIGHT POLES AND CIRCUITRY
08/11/2010
08/11/2010
02/07/2011
10/04/2010
Locations
Contacts
KASA ELECTRIC LLC, Address:1911-G SW 40 HWY  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 02/07/2011 10/29/2010
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $54.10 $54.10 Paid 08/11/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underground Electrical Inspection - Commercial Partial 08/12/2010
Correction
Partial Correction
08/12/2010
BURIED CONDUIT FOR SITE ELECTRICAL 1" PVC CONDUIT IN PLACE WEST OF DRIVE-THROUGH CANOPY; ENSURE >=18" COVER IN LAWN AREAS NOT TO RECEIVE CONCRETE SLAB. (NO SITE ELECTRICAL PLAN ON SITE TO INDICATE EXTENT OF CONDUIT REQUIRED.) NO ISSUES FOUND ON MATERIAL & WORKMANSHIP
Rough Electrical Inspection - Commercial Partial 08/12/2010
Correction
Corrective Action Required
08/12/2010
READINESS FOR INSPECTION ABOVE-GRADE ELECTRICAL NOT YET FOUND IN PLACE
Underground Electrical Inspection - Commercial Request Complete 8/11/2010 8/12/2010 08/12/2010
Underground Electrical Inspection - Commercial Partial 08/13/2010
Correction
Partial Correction
08/13/2010
BURIED CONDUIT FOR SITE ELECTRICAL 1" PVC CONDUIT IN PLACE WEST OF DRIVE-THROUGH CANOPY; CONDUITS TO LIGHT POLES ENSURE >=18" COVER IN LAWN AREAS NOT TO RECEIVE CONCRETE SLAB. (NO SITE ELECTRICAL PLAN ON SITE TO INDICATE EXTENT OF CONDUIT REQUIRED.) NO ISSUES FOUND ON MATERIAL & WORKMANSHIP
Correction
Corrective Action Required
08/13/2010
BURIED DEPTH PER NEC TABLE 300.5 ALL CONDUITS UNDER DRIVEWAY OR SURFACE SUBJECTED TO VEHICULAR TRAFFIC AND PARK LOT SHALL BE MIN 24" BELOW GRADE SUCH AS CONDUITS UNDER DRIVE-THROUGH CANOPY AND TO SIGN AT STREET ENTRY
Underground Electrical Inspection - Commercial Request Complete 8/13/2010 8/13/2010 08/13/2010
Underground Electrical Inspection - Commercial Passed 08/17/2010
Correction
Resolved
08/17/2010
BURIED CONDUIT FOR SITE ELECTRICAL 1" PVC CONDUIT IN PLACE WEST OF DRIVE-THROUGH CANOPY; CONDUITS TO LIGHT POLES NO SITE ELECTRICAL PLAN ON SITE TO INDICATE EXTENT OF CONDUIT REQUIRED. NO ISSUES FOUND ON MATERIAL & WORKMANSHIP
Correction
Resolved
08/17/2010
BURIED DEPTH PER NEC TABLE 300.5
Underground Electrical Inspection - Commercial Request Complete 8/16/2010 8/17/2010 08/17/2010
Piers/Caissons Inspection - Commercial Passed 09/02/2010
Correction
Resolved
09/02/2010
None 2 LIGHT POLE PIERS APPROVED TO POUR
Piers/Caissons Inspection - Commercial Failed 09/02/2010
Correction
Corrective Action Required
09/02/2010
See Comment - CONDUIT & GROUND WIRE NOT INSTALLED. CALL FOR REINSPECTION Light Poles
Rough Electrical Inspection - Commercial Partial 09/03/2010
Correction
Corrective Action Required
09/03/2010
None - OKAY TO INSTALL CEILING TILE. Drive-Thru
Final Electrical Inspection - Commercial Passed 09/30/2010
Piers/Caissons Inspection - Commercial Passed 10/01/2010
Rough Electrical Inspection - Commercial Passed 10/01/2010
Correction
Resolved
10/01/2010
READINESS FOR INSPECTION
Correction
Resolved
10/01/2010
None
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home