Permit Application Status

B1000833


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1000833
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE
07/22/2010
07/30/2010
04/25/2011
05/25/2011
Locations
Contacts
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD  
SUMMIT ELECTRICAL & MECHANICAL LLC, Address:241 NW COMMERCE CT  
SCOTT AND KAREN SHULTZ, Address:4104 SW PRYOR RD  
HOMEOWNER  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/25/2011 10/29/2010
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Correction

CA - If decks are not shown on plot plans submitted at the time of permit application for the structure, and decks are proposed to be installed prior to occupancy, a separate approval and permit is required prior to construction of such deck(s).
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $873.70 $873.70 Paid 07/30/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 08/05/2010
Correction
Resolved
08/05/2010
R403.1.4 Footing Depth (IRC)
Correction
Resolved
08/05/2010
R403.1.1 Minimum size of footings (IRC)
Correction
Resolved
08/05/2010
R403.1 Footing support (IRC)
Correction
Resolved
08/05/2010
LSCO 7-921 Column Pad Reinforcement (IRC)
Correction
Resolved
08/05/2010
LSCO 7-920 Footing Reinforcement (IRC)
Underslab Plumbing Inspection - Residential Passed 08/17/2010
Correction
Resolved
08/17/2010
NONE None
Piers/Caissons Inspection - Residential Passed 09/08/2010
Correction
Resolved
09/08/2010
NONE None
Underground Electrical Inspection - Residential Request Complete 10/4/2010 10/4/2010 10/04/2010
Water Service Inspection - R Passed 10/25/2010
Correction
Resolved
10/25/2010
NONE None FROM EXISTING WATER SERVICE TO HOUSE
Water Service Inspection - Residential Request Complete 10/25/2010 10/25/2010 10/25/2010
Underslab Plumbing Inspection - Residential Passed 10/28/2010
Correction
Resolved
10/28/2010
NONE None GARAGE DRAIN ALSO
Gas Piping Inspection - Residential Passed 10/28/2010
Correction
Resolved
10/28/2010
NONE None
Gas Service Inspection - Residential Passed 10/28/2010
Correction
Resolved
10/28/2010
NONE None
All Rough Inspection - Residential Failed 11/4/2010 at 12:00 AM 11/04/2010
M1601 DUCT CONSTRUCTION
Corrective Action Required
11/04/2010
VENT ALL BATH FANS
R802.3 Framing details
Corrective Action Required
11/04/2010
CEILING OF KITCHEN AND GREAT ROOM- INSTALL 3 2X12S PER PLANS. 2 LOCATIONS 2. SUPPORT LVL UNDER DINNING ROOM, IN UNFINISHED BSMT AREA.
R602.8 Fireblocking required
Corrective Action Required
11/04/2010
WOOD WALL FRAMING. Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. Fireblocking shall be provided in wood-frame construction in the following locations. 1. In concealed spaces of stud walls and partitions, including furred spaces and parallel rows of studs or staggered studs; as follows: 1.1. Vertically at the ceiling and floor levels. 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). 2. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 3. In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with Section R311.2.2. 4. At openings around vents, pipes, ducts, cables and wires at ceiling and floor level, with an approved material to resist the free passage of flame and products of combustion. 5. For the fireblocking of chimneys and fireplaces, see Section R1003.19. 6. Fireblocking of cornices of a two-family dwelling is required at the line of dwelling unit separation.*********** FIRESTOP ALL VERTICAL TO HORIZONTAL AT FIR DOWNS IN BSMT AND OVER BSMT FIREPLACE FROM JOIST SPACE. FRONT BSMT WALL AT BAR- FIRESTOP BETWEEN WALLS FROM JOIST SPACE.
M403 MECHANICAL VENTILATION
Corrective Action Required
11/04/2010
MUTI VENT CONNECTIONS AT DBL WATER HEATERS- INSTALL DBL WALL CONNECTOR AT WATER HEATER FLUES
E3305 EQUIPMENT LOCATION AND CLEARANCES
Corrective Action Required
11/04/2010
COMPLELTE ECTRICAL IN BSMT CEILING
Corrective Action Required
11/04/2010
All Rough Inspection - Residential Partial 11/8/2010 at 12:00 AM 11/08/2010
M1601 DUCT CONSTRUCTION
Resolved
11/08/2010
VENT ALL BATH FANS
R802.3 Framing details
Resolved
11/08/2010
CEILING OF KITCHEN AND GREAT ROOM- INSTALL 3 2X12S PER PLANS. 2 LOCATIONS 2. SUPPORT LVL UNDER DINNING ROOM, IN UNFINISHED BSMT AREA.
R602.8 Fireblocking required
Corrective Action Required
11/04/2010
.*********** FIRESTOP ALL VERTICAL TO HORIZONTAL AT FIR DOWNS IN BSMT AND OVER BSMT FIREPLACE FROM JOIST SPACE. FRONT BSMT WALL AT BAR- FIRESTOP BETWEEN WALLS FROM JOIST SPACE.
M403 MECHANICAL VENTILATION
Resolved
11/08/2010
MUTI VENT CONNECTIONS AT DBL WATER HEATERS- INSTALL DBL WALL CONNECTOR AT WATER HEATER FLUES
All Rough Inspection - Residential Passed 11/10/2010 at 12:00 AM 11/10/2010
R602.8 Fireblocking required
Resolved
11/10/2010
.*********** FIRESTOP ALL VERTICAL TO HORIZONTAL AT FIR DOWNS IN BSMT AND OVER BSMT FIREPLACE FROM JOIST SPACE. FRONT BSMT WALL AT BAR- FIRESTOP BETWEEN WALLS FROM JOIST SPACE.
Electrical Service Inspection Passed 11/30/2010
Occupancy Inspection - Codes Residential Full C of O 1/6/2011 at 12:00 AM 05/25/2011
Misc
Resolved
05/25/2011
EXTERIOR ITEMS ONLY: COMPLETE DECK AND HAND/ GAURDRAIL, STAIR HANDRAILS. APPROVED FOR TCO
Misc
Resolved
02/10/2011
OK TO MOVE ITMES IN. OWENR TO BE PRESENT DURING INSPECTION. CALL SCOTT AT 506-8750 FOR INSPECTION
Resolved
02/10/2011
Documents & Images
Date Uploaded File Type Document Name
11/04/2010 Letter Inspection Summary
11/08/2010 Letter Inspection Summary
11/10/2010 Letter Inspection Summary
11/11/2010 Plans 20101111152408168.pdf
11/30/2010 Letter Inspection Summary
01/06/2011 Letter Inspection Summary
01/06/2011 Letter Inspection Summary
02/10/2011 Letter Temporary Certificate of Occupancy
05/25/2011 Letter Field Certificate of Occupancy
05/27/2011 Letter Final Certificate of Occupancy
05/27/2011 Letter 20110527085636283.pdf
08/21/2013 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home