Summary
B1000360
Building Permit - Residential
Final Completion
ADD/ALTER SINGLE FAMILY
DECK
04/19/2010
04/19/2010
10/16/2010
12/18/2013
Locations
Contacts
CHRIS VAUGHN, Address:300 NW O'BRIEN  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/16/2010 10/29/2010
Correction

CA - If decks are not shown on plot plans submitted at the time of permit application for the structure, and decks are proposed to be installed prior to occupancy, a separate approval and permit is required prior to construction of such deck(s).
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $52.71 $52.71 Paid 04/19/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Deck Final Inspection - Residential Failed 8/16/2012 at 12:00 AM 08/16/2012
Misc
Corrective Action Required
08/16/2012
COMPLIANT HANDRAILS TO BE PROVIDED AT DECK STAIRS
Deck Final Inspection - Residential Partial 9/16/2013 at 12:00 AM 09/16/2013
Misc
Resolved
09/16/2013
COMPLIANT HANDRAILS TO BE PROVIDED AT DECK STAIRS
Misc
Corrective Action Required
09/16/2013
IRC R316.2 STAIR TREAD / RISER / GUARD TRIANGULAR OPENINGS AT OPEN SIDE(S) OF STAIRWAY: OPENINGS MUST NOT ALLOW PASSAGE OF 6" SPHERE
Deck Final Inspection - Residential Partial 9/26/2013 at 12:00 AM 09/26/2013
Misc
Corrective Action Required
09/16/2013
IRC R316.2 STAIR TREAD / RISER / GUARD TRIANGULAR OPENINGS AT OPEN SIDE(S) OF STAIRWAY: OPENINGS MUST NOT ALLOW PASSAGE OF 6" SPHERE
Investigation Inspection Complete 9/26/2013 at 12:00 AM 09/26/2013
Deck Final Inspection - Residential Partial 9/26/2013 at 12:00 AM 09/26/2013
Misc
Corrective Action Required
09/26/2013
IRC R316.2 STAIR TREAD / RISER / GUARD TRIANGULAR OPENINGS AT OPEN SIDE(S) OF STAIRWAY: OPENINGS MUST NOT ALLOW PASSAGE OF 6" SPHERE
Deck Final Inspection - Residential Passed 12/17/2013 at 12:00 AM 12/17/2013
Misc
Resolved
12/17/2013
IRC R316.2 STAIR TREAD / RISER / GUARD TRIANGULAR OPENINGS AT OPEN SIDE(S) OF STAIRWAY: OPENINGS MUST NOT ALLOW PASSAGE OF 6" SPHERE
Documents & Images
Date Uploaded File Type Document Name
08/13/2012 Letter Permit Expired Notice
08/13/2012 Letter Permit Expired Notice
09/16/2013 Letter Inspection Summary
09/26/2013 Letter Inspection Summary
09/26/2013 Letter Inspection Summary
12/17/2013 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home