Permit Application Status

B1000258


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1000258
Building Permit - Residential
Final Completion
ADD/ALTER SINGLE FAMILY
BASEMENT FINISH
03/29/2010
03/29/2010
09/25/2010
07/21/2010
Locations
Contacts
A & D HEATING AND COOLING INC, Address:2006 W MAIN  
CENTURY PLUMBING, Address:14001 CENTURY LANE  
TROY LOVINS, Address:1304 NE ERNEST WAY  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 09/25/2010 10/29/2010
Correction

CA - If decks are not shown on plot plans submitted at the time of permit application for the structure, and decks are proposed to be installed prior to occupancy, a separate approval and permit is required prior to construction of such deck(s).
Correction

Codes Administration- Bedrooms located in basements shall have at least one operable window or door approved for emergency escape which opens to the exterior. All escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The net clear openable height shall be 24 inches. The minimum net clear openable width shall be 20 inches. The finished sill height shall not exceed 44 inches above the finished floor. (UBC Section 1204).
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $114.44 $114.44 Paid 03/29/2010
89 Sewer Tap Fees $30.00 $30.00 Paid 03/29/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 05/28/2010
Correction
Corrective Action Required
05/28/2010
MISC PAN OFF WALL SPACE FROM RETURN AIR SPACE
Correction
Corrective Action Required
05/28/2010
R602.8 Fireblocking (IRC) -FIREBLOCK ALL BASEMENT FURRED WALL SPACE EVERY 10 FT HORIZONTALLY AND AT CEILING INTERSECTION WITH CEILING JOISTS SPACE AND FURDOWN SPACE -INSULATE WALL ALONG FOUNDATION WALL AND EXTERIOR WALL AS REQUIRED *OK TO INSULATE. DO NOT ROCK
All Rough Inspection - Residential Passed 06/04/2010
Correction
Resolved
06/04/2010
MISC PAN OFF WALL SPACE FROM RETURN AIR SPACE OK TO ROCK
Correction
Resolved
06/04/2010
R602.8 Fireblocking (IRC) -FIREBLOCK ALL BASEMENT FURRED WALL SPACE EVERY 10 FT HORIZONTALLY AND AT CEILING INTERSECTION WITH CEILING JOISTS SPACE AND FURDOWN SPACE -INSULATE WALL ALONG FOUNDATION WALL AND EXTERIOR WALL AS REQUIRED *OK TO INSULATE. DO NOT ROCK
Final Inspection - Residential Passed 07/20/2010
Correction
Resolved
07/20/2010
NONE None BASEMENT FINISH APPROVED
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home