B1000174


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B1000174
Building Permit - Commercial
Certificate of Occupancy
CHANGE OF TENANT
CUTE NAILS TENANT FINISH
03/03/2010
03/03/2010
08/30/2010
03/31/2010
Locations
Contacts
C & S FURNACE COMPANY INC, Address:PO BOX 520207  
CUTE NAILS, Address:244 NW OLDHAM PKWY  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/30/2010 10/29/2010
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $30.00 $30.00 Paid 03/03/2010
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Partial 03/04/2010
Correction
Partial Correction
03/04/2010
ON-SITE COURTESY VISIT W/ G.C.; M.C.; TENANT RE EXHAUST SYSTEM
Occupancy Inspection - Codes Commercial Failed 03/16/2010
Correction
Corrective Action Required
03/16/2010
Receive Fire Department approval SEE REPORT PROVIDED BY CHIEF JIM EDEN
Correction
Corrective Action Required
03/16/2010
Receive Water Utilities Approval CONTACT BEN HASKAMP PHONE 816-969-1930
Correction
Corrective Action Required
03/16/2010
WATER HEATER TEMPERATURE/PRESSURE RELIEF DISCHARGE PIPING IPC 504.6 NOT INSTALLED TO WITHIN 6" OF FLOOR
Correction
Corrective Action Required
03/16/2010
DRAIN PIPING WHERE SINK REMOVED REAR ROOM MUST BE CAPPED
Correction
Resolved
03/16/2010
LOCAL CAPTURE EXHAUST AT NAIL STATIONS
Correction
Corrective Action Required
03/16/2010
WIRING ABOVE CEILING OPEN SPLICES; UNSECURED NM CABLE; UNUSED BOX OPENINGS; SHEATH STRIPPED FROM NM CABLE; DROP CORD IN CONCEALED SPACE... NON-COMPLIANT
Correction
Corrective Action Required
03/16/2010
DRYER VENT DISCHARGE TERMINATES ABOVE CEILING
Occupancy Inspection - Codes Commercial Failed 03/18/2010
Correction
Partial Correction
03/18/2010
Receive Fire Department approval
Correction
Partial Correction
03/18/2010
Receive Water Utilities Approval BACKFLOW PREVENTION DEVICE TEST RESULTS TO BE PROVIDED TO BEN HASKAMP PHONE 816-969-1930
Correction
Resolved
03/18/2010
WATER HEATER TEMPERATURE/PRESSURE RELIEF DISCHARGE PIPING
Correction
Resolved
03/18/2010
DRAIN PIPING WHERE SINK REMOVED
Correction
Resolved
03/18/2010
WIRING ABOVE CEILING
Correction
Resolved
03/18/2010
DRYER VENT DISCHARGE
Correction
Corrective Action Required
03/18/2010
ELECTRICAL FEED FOR PEDICURE CHAIRS NOT COMPLIANT
Miscellaneous Inspection Passed 03/18/2010
Correction
Resolved
03/18/2010
ON-SITE COURTESY VISIT
Rough Mechanical Inspection - Commercial Passed 03/18/2010
Occupancy Inspection - Codes Commercial Failed 03/19/2010
Correction
Resolved
03/19/2010
ROOFTOP EXHAUST FAN NO ISSUES FOUND
Occupancy Inspection - Codes Commercial Failed 03/24/2010
Correction
Resolved
03/24/2010
Receive Fire Department approval
Correction
Resolved
03/24/2010
Receive Water Utilities Approval PER BEN HASKAMP 3/24/2010
Occupancy Inspection - Codes Commercial Passed 03/30/2010
Correction
Resolved
03/30/2010
Receive Fire Department approval PER CPT JOE DIR
Correction
Resolved
03/30/2010
ELECTRICAL FEED FOR PEDICURE CHAIRS
Correction
Resolved
03/30/2010
ROOFTOP EXHAUST FAN
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home