Permit Application Status

B0800476


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0800476
Building Permit - Commercial
Certificate of Occupancy
MCINTOSH JAMES F & DENISE D
NEW TENANT FINISH
PAMELAS HOME DESIGN TENANT FINISH
04/24/2008
05/15/2008
12/10/2008
01/13/2010
Locations
Contacts
TEMP CON INC, Address:15670 S. KEELER  
VAN DEURZEN & ASSOCIATES, Address:11011 KING ST, STE 130  
FPC COMMERCIAL, Address:301 SE DOUGLAS SUITE 201  
TRI-COUNTY PLUMBING, LLC, Address:100 W PACIFIC  
PINNACLE CONSTRUCTION SOLUTION LLC, Address:19100 S AUTUMN  
MCINTOSH JAMES F & DENISE D, Address:PO BOX 820  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/11/2008 10/29/2010
Correction

Fire Department- 2006 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenat commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm).
Correction

Fire Department- 2006 IFC 703.1- Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Codes Administration - 2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture.
Correction

Codes Administration - 2006 IPC 403.4 - Required public toilet facilities. Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The accessible route to public facilities shall not pass through kitchens, storage rooms, closets or similar spaces. Employess shall be provided with toilet facilities in all occupancies. Employee toilet facilities shall be either separate or combined employee and public toilet facilities.
Correction

Codes Administration - The mechanical plan for the tenant finish does not match the mechanical plan for the shell building.
Correction

Codes Administration - The application does not provide specifications for the installation of the electrical system.
Correction

Codes Administration - A schedule for the electrical panel has not been provided.
Correction

Codes Administration - The plans do not indicate if a ceiling is to be installed.
Correction

Codes Administration - The floor/ceiling assembly above this space and the north and east walls are rated assemblies but it is not indicated on the plans.
Correction

Codes Administration - A finish schedule for the space has not been provided.
Correction

Codes Administration - The plans do not indicate how the new walls are to terminate at the top.
Correction

Codes Administration - Information on the doors to be installed has not been provided.
Correction

Codes Administration - A mop sink has been added to the plans but information on the installation have not been provided.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $86.95 $86.95 Paid 05/15/2008
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Not Ready 05/19/2008
Correction
Corrective Action Required
05/19/2008
READINESS FOR INSPECTION LSCO SEC 7-142; IBC 106: NO INSPECTIONS WITHOUT PERMIT DRAWINGS PERMIT DRAWINGS NOT FOUND ON SITE
All Rough Inspection - Commercial Not Ready 05/20/2008
Correction
Corrective Action Required
05/20/2008
READINESS FOR INSPECTION IBC 109.1 WORK REQUESTED FOR INSP ALREADY COVERED
All Rough Inspection - Commercial Passed 05/22/2008
Correction
Resolved
05/22/2008
READINESS FOR INSPECTION CONTINGENT ON SHELL OK TO COVER WHEN READY
Electrical Service Inspection Passed 06/03/2008
Correction
Resolved
06/03/2008
ELECTRICAL SERVICE INSTALLATION ENSURE PANEL FRONT IS IN PLACE BEFORE REQUESTING SERVICE ACTIVATION. 200A MLO PANEL RELEASE SERVICE
Miscellaneous Inspection Passed 06/06/2008
Occupancy Inspection - Codes Commercial Not Ready 06/06/2008
Correction
Partial Correction
06/06/2008
USE / OCCUPANCY APPROVAL STATUS KEEP ELECTRICAL RECEPTACLES 24" CLEAR FOR INSPECTION/TESTING UNTIL APPROVED. OK TO MOVE IN CONTENTS CONTINGENT ON BELOW:
Correction
Corrective Action Required
06/06/2008
Receive Fire Department approval NOT READY FOR INSPECTION
Occupancy Inspection - Codes Commercial Failed 06/11/2008
Correction
Partial Correction
06/11/2008
USE / OCCUPANCY APPROVAL STATUS SEE TEMPORARY OCCUPANCY
Correction
Partial Correction
06/11/2008
Receive Fire Department approval OK FOR TEMP OCCUPANCY PER CPT JOE DIR 6/11/08
Correction
Corrective Action Required
06/11/2008
ELECTRICAL RECEPTACLE/SWITCH FACE PLATES ENSURE ALL IN PLACE NEC 370-25; 410-56
Correction
Corrective Action Required
06/11/2008
ELECTRICAL PANEL SCHEDULE REQUIRED FOR TEMPORARY OCCUPANCY. PLACE IMMEDIATELY. SERVICE PANEL
Occupancy Inspection - Codes Commercial Failed 06/16/2008
Correction
Resolved
06/16/2008
ELECTRICAL RECEPTACLE/SWITCH FACE PLATES
Correction
Partial Correction
06/16/2008
ELECTRICAL PANEL SCHEDULE ON PANEL FRONT IN PLACE @ SERVICE PANEL LABEL 1-42 POSITIONS
Occupancy Inspection - Codes Commercial Failed 07/29/2008
Correction
Resolved
07/29/2008
Receive Fire Department approval PER CPT JOE DIR 6/12/08
Occupancy Inspection - Codes Commercial Failed 08/06/2008
Correction
Partial Correction
08/06/2008
USE / OCCUPANCY APPROVAL STATUS SHELL PERMIT NOT CLOSED SEE TEMPORARY OCCUPANCY
Correction
Resolved
08/06/2008
ELECTRICAL PANEL SCHEDULE
Occupancy Inspection - Codes Commercial Passed 01/12/2010
Correction
Resolved
01/12/2010
USE / OCCUPANCY APPROVAL STATUS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home