Permit Application Status

B0702506


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0702506
Building Permit - Commercial
Certificate of Occupancy
NETTERVILLE ROBERT T & LINDA L
NEW COMMERCIAL
CHANGE OF USE FROM RESIDENTIAL TO COMMERCIAL
11/28/2007
01/11/2008
07/09/2008
04/29/2008
Locations
Contacts
BOB NETTERVILLE, Address:3646 NE BEECHWOOD DR  
BRICOBE MECHANICAL SERVICE CO, Address:2421 NE OLD PAINT RD  
SUMMIT ELECTRICAL & MECHANICAL LLC, Address:PO BOX 1573  
TOTAL HOME SERVICES, Address:1941 N 45TH  
NETTERVILLE ROBERT T & LINDA L, Address:3646 NE BEECHWOOD DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 06/28/2008 10/29/2010
Correction

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Codes Administration - ICC/ANSI A117.1 2003 405.7.3 - Length. Landings shall have a clear length of 60 inches minimum.
Correction

Codes Administration - ICC/ANSI A117.1 2003 405.7.4 - Change in direction. Ramps that change direction at ramp landings shall hbe sized to provide a turning space complying with Section 304.3.
Correction

Codes Administration - ICC/ANSI A117.1 2003 405.7.5 - Doorways. Where doorways are adjacent to a ramp landing, maneuvering clearnances required by Sections 404.2.3 and 404.3.2 shall be permitted to overlap the landing area. Where doors that are subject to locking are adjacent to a ramp landing, landings shall be sized to provide a turning space complying with Sections 304.3.
Correction

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall.
Correction

Codes Administration - 2006 IBC 1008.1.4 - Floor elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope).
Correction

Codes Administration - 2006 IBC 1109.4 - Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC A117.1.
Correction

Codes Administration - 2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design.
Correction

Codes Administration - Information on the new stairs have not been provided.
Correction

Codes Administration - Information on the construction of the ramp has not been provided.
Correction

Codes Administration - The plans have what appears to be storm doors on the exterior doors. Egress doors are not allowed to have more than one door or require more than one action to open the door.
Correction

Codes Administrtion - The site plan does not provide the property lines. These are required to determine if the exterior walls area required to be rated based on locate to the property lines per Table 602.
Correction

Codes Administration - Information showing compliance with the accessiblity requirements for lavatories has not been provided.
Correction

Codes Administration - Information on the any plumbing, electrical or mechanical work has not been provided.
Correction

Codes Administration - The site plan does not include the deminsions of the parking stalls. Also, I believe that this alley was one way from the south to the north which would conflict with the direction of the parking.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Commercial Failed 03/17/2008
Correction
Corrective Action Required
03/17/2008
REQUIRED HANDRAIL AT EAST ENTRANCE STEPS NOT INSTALLED
Correction
Corrective Action Required
03/17/2008
ELECTRICAL RECEPTACLE(S) AT WET LOCATIONS NEC 406.8 WEATHERPROOF COVER REQ'D
Correction
Corrective Action Required
03/17/2008
CHANGE IN LEVEL AT BOTTOM OF RAMP ANSI SECTIONS 304/405/406 APPROXIMATELY 3-1/4" MAX > 1/2" MUST BE RAMPED PER
Correction
Corrective Action Required
03/17/2008
Receive Fire Department approval APPROVAL STATUS TO BE DETERMINED
Occupancy Inspection - Codes Commercial Failed 03/17/2008
Correction
Resolved
03/17/2008
Receive Fire Department approval PER JOE DIR 3/17/08
Occupancy Inspection - Codes Commercial Passed 04/28/2008
Correction
Resolved
04/28/2008
REQUIRED HANDRAIL AT EAST ENTRANCE STEPS
Correction
Resolved
04/28/2008
ELECTRICAL RECEPTACLE(S) AT WET LOCATIONS
Correction
Resolved
04/28/2008
CHANGE IN LEVEL AT BOTTOM OF RAMP
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents