Permit Application Status

B0702396


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0702396
Building Permit - Commercial
Certificate of Occupancy
CITY OF LEES SUMMIT
CHANGE OF TENANT
REDISCOVER TENANT FINISH
11/06/2007
11/29/2007
05/27/2008
04/07/2008
Locations
Contacts
D'AGOSTINO MECHANICAL CONTRACT INC, Address:4440 OLIVER ST  
D'AGOSTINO MECHANICAL CONTRACTORS, INC, Address:4440 OLIVER STREET  
D'AGOSTINO MECHANICAL CONTRACT INC, Address:4440 OLIVER ST  
D'AGOSTINO MECHANICAL CONTRACTORS, INC, Address:4440 OLIVER STREET  
DMA ELECTRIC, Address:7468 W 162ND TR  
TORII LLC, Address:16210 W 128TH ST  
GREER ARCHITECTURE, Address:5711 COTTONWOOD  
CITY OF LEES SUMMIT, Address:PO BOX 1600  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 05/19/2008 10/29/2010
Correction

Fire Department- 2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Codes Administration - ICC/ANSI A117.1 2003 604.5.1 - Fixed sidewall grab bars. Fixed sidewall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor, and with the center line of the bar located between 39 inches and 41 inches from the rear wall.
Correction

Codes Administration - 2006 IBC 1210.1 - Floors. In other than dwelling units, toilet and bathing room floors shall have a smooth, hard, nonabsorbant surface that extends upward onto the walls at least 6 inches.
Correction

Codes Administration - 2006 IBC 1210.2 - Walls. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. Exceptions: 1. Dwelling units and sleeping units. 2. Toilet rooms that are not accessible to the public and which have not more than one water closet. Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture.
Correction

Fire Department- 2006 IFC 1006.3 -Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702 of the International Building Code.
Correction

Codes Administration - An accessible route is not provided to this facility.
Correction

Codes Adminsitration - The building infromation on Sheet A1 indicates a construction type of II-B. This construction type does not allow for the use of combustible materials except as specified in Chapter 6 of the IBC. The actual construction type of this building is V-B.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $408.50 $408.50 Paid 11/29/2007
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Partial 01/23/2008
Correction
Partial Correction
01/23/2008
WALK-THROUGH INSPECTION 1/23/08 TO BE SCHEDULED WITH C BRYANT (TORII LLC) ABOVE-CEILING INSP REQ'D
Above Ceiling Inspection Failed 01/24/2008
Correction
Corrective Action Required
01/24/2008
HOLES/OPENINGS IN GWB HARD LID ABOVE 1ST FLR ACT CEILING NOT CLOSED / REPAIRED
Correction
Corrective Action Required
01/24/2008
ELECTRICAL CONDUCTORS AT HARD LID ELEVATION NOT ENCLOSED SOME NOT WIRE-NUTTED
Correction
Corrective Action Required
01/24/2008
LOW-VOLTAGE ELECTRICAL CABLE IF ABANDONED RECOMMEND REMOVAL
Correction
Corrective Action Required
01/24/2008
ABS PLUMBING PIPING ABOVE SPACE #120 LEAKING MOISTURE AT FITTING(S)
Above Ceiling Inspection Failed 01/30/2008
Correction
Resolved
01/30/2008
ABS PLUMBING PIPING ABOVE SPACE #120 LEAK REPAIRED
Above Ceiling Inspection Passed 02/01/2008
Correction
Resolved
02/01/2008
HOLES/OPENINGS IN GWB HARD LID ABOVE 1ST FLR ACT CEILING
Correction
Resolved
02/01/2008
ELECTRICAL CONDUCTORS AT HARD LID ELEVATION
Correction
Resolved
02/01/2008
LOW-VOLTAGE ELECTRICAL CABLE IF ABANDONED RECOMMEND REMOVAL
Miscellaneous Inspection Failed 02/04/2008
Correction
Corrective Action Required
02/04/2008
TEST
Miscellaneous Inspection Passed 02/04/2008
Correction
Resolved
02/04/2008
TEST
All Rough Inspection - Commercial Passed 02/04/2008
Correction
Resolved
02/04/2008
WALK-THROUGH INSPECTION 1/23/08 WITH C BRYANT (TORII LLC)
Occupancy Inspection - Codes Commercial Not Ready 02/04/2008
Correction
Corrective Action Required
02/04/2008
ELECTRICAL RECEPTACLES @ 1ST FLOOR RESTROOMS NOT GFCI PROTECTED
Correction
Corrective Action Required
02/04/2008
ELECTRICAL BOX LEFT OF INTERIOR LADDER TO LOFT NOT CLOSED
Correction
Corrective Action Required
02/04/2008
SWITCH BOX BEHIND FURNACE @ BASEMENT SOUTH NOT SECURED TO STRUCTURE
Correction
Corrective Action Required
02/04/2008
APPARENT MOLD ON WALL AT MECHANICAL ROOM ADVISE TO CHECK AND REMEDIATE IF RECOMMENDED
Correction
Corrective Action Required
02/04/2008
EXTERIOR ELECTRICAL RECEPTACLES @ S.E. CORNER CHECK FOR OPEN GROUND
Correction
Corrective Action Required
02/04/2008
WEST ENTRANCE CORRIDOR SHOWN TO BE REMOVED
Correction
Corrective Action Required
02/04/2008
Receive Fire Department approval
Occupancy Inspection - Codes Commercial Not Ready 02/04/2008
Occupancy Inspection - Codes Commercial Failed 02/05/2008
Correction
Corrective Action Required
02/05/2008
ELECTRICAL RECEPTACLES @ 1ST FLOOR RESTROOMS PROVIDE GFCI PROTECTION AND BASEMENT BREAK ROOM
Correction
Corrective Action Required
02/05/2008
Receive Fire Department approval SEE REPORT PER JOE DIR. EMERGENCY LIGHTING AND EXIT SIGNAGE TO BE REPAIRED/INSTALLED PER JOE'S REPORT.
Correction
Corrective Action Required
02/05/2008
VERT. GRAB BAR INSTALL VERT. GRAB BAR PER RE-SUB. DATED 11/21/07. MIN. 18" IN LENGTH 39"-42" FROM REAR WALL AND FLOOR. 1ST FLOOR UNI-SEX BATH
Correction
Corrective Action Required
02/05/2008
HANDRAILS (IBC) SHALL RETURN TO THE WALL. ALL HANDRAILS
Correction
Corrective Action Required
02/05/2008
SUB-PANEL LABEL SUB-PANEL AS A TERMINATED OR DEAD PANEL. LOCATED AT TOP OF STAIRS TO BASEMENT OFFICE
Correction
Corrective Action Required
02/05/2008
EXTERIOR GFCI PROTECTION PROVIDE GFCI PROTECTION FOR ALL EXTERIOR RECEP.
Correction
Resolved
02/05/2008
Receive Water Utilities Approval APPROVED PER BEN
Occupancy Inspection - Codes Commercial Failed 02/07/2008
Correction
Resolved
02/07/2008
ELECTRICAL RECEPTACLES @ 1ST FLOOR RESTROOMS AND BASEMENT BREAK ROOM
Correction
Resolved
02/07/2008
ELECTRICAL BOX LEFT OF INTERIOR LADDER TO LOFT CLOSED
Correction
Resolved
02/07/2008
SWITCH BOX BEHIND FURNACE @ BASEMENT SOUTH SECURED TO STRUCTURE
Correction
Resolved
02/07/2008
APPARENT MOLD ON WALL AT MECHANICAL ROOM ADVISE TO CHECK AND REMEDIATE IF RECOMMENDED
Correction
Resolved
02/07/2008
EXTERIOR ELECTRICAL RECEPTACLES @ S.E. CORNER OR DE-ACTIVATE CHECK FOR OPEN GROUND ENSURE GFCI PROTECTION
Correction
Corrective Action Required
02/07/2008
WEST ENTRANCE CORRIDOR SHOWN TO BE REMOVED
Correction
Partial Correction
02/07/2008
Receive Fire Department approval SEE REPORT PER JOE DIR
Correction
Resolved
02/07/2008
VERT. GRAB BAR 1ST FLOOR UNI-SEX BATH
Correction
Resolved
02/07/2008
HANDRAILS (IBC) RETURNED TO THE WALL
Correction
Corrective Action Required
02/07/2008
SUB-PANEL LABEL SUB-PANEL AS A TERMINATED OR DEAD PANEL. LOCATED AT TOP OF STAIRS TO BASEMENT OFFICE
Correction
Resolved
02/07/2008
EXTERIOR GFCI PROTECTION SEE ABOVE
Occupancy Inspection - Codes Commercial Failed 04/03/2008
Correction
Resolved
04/03/2008
Receive Fire Department approval PER CPT JOE DIR 4/2/08
Correction
Resolved
04/03/2008
SUB-PANEL LABEL SUB-PANEL AS A TERMINATED OR DEAD PANEL. LOCATED AT TOP OF STAIRS TO BASEMENT OFFICE
Occupancy Inspection - Codes Commercial Passed 04/04/2008
Correction
Resolved
04/04/2008
WEST ENTRANCE CORRIDOR REMOVAL IS TO BE INCLUDED WITHIN SCOPE OF PLANNED PROJECT ON ADJACENT PROPERTY, PER INFORMATION FROM RON COX 4/3/08. SHOWN TO BE REMOVED EXCLUDED FROM THIS PERMIT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home