Summary
B0700804
Building Permit - Residential
Certificate of Occupancy
KINDER LAURA A
NEW 3 OR 4 FAMILY
4-PLEX
04/20/2007
04/26/2007
09/29/2009
08/26/2009
Locations
Contacts
UNITED HEATING & COOLING, Address:301 DUCK RD  
KLOPFENSTINE CONSTRUCTION, Address:19606 W 96TH TER  
C.D. MCCLAIN ELECTRICAL, Address:PO BOX 1494  
CLASSIC PLUMBING INC, Address:PO BOX 460  
KINDER LAURA A, Address:807 NE LONE HILL DR  
CARLSON JON & DELANNE, Address:805 NE LONE HILL DR  
PINNACLE BANK, Address:26500 E COLBERN BOX 6650 RD  
WEST JACQUELYN R, Address:801 NE LONE HILL DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 10/21/2007 10/29/2010
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - If decks are not shown on plot plans submitted at the time of permit application for the structure, and decks are proposed to be installed prior to occupancy, a separate approval and permit is required prior to construction of such deck(s).
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2003 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

All residential projects applied for after May 6, 2006 shall have a maximum stair rise of 7-3/4 inches and a minimum tread depth of 10". This project was applied for after May 6, 2006 and therefore must comply with this requirement.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Correction

Codes Administration - 2003 IRC 311.5.2 - Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

Codes Administration - 2003 IRC 401.3 - Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation wall shall fall a minimum of 6 inches with the first 10 feet. Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be provided to ensure drainage away from the structure.
Correction

Codes Administration - 2003 IRC 403.1.6 - Foundation anchorage. When braced wall panels are supported directly on continous foundations, the wall wood sill plate or cold-formed steel bottom track shall be anchored to the foundation in accordance with this section. The wood sole plate at exterior walls in monolithic slabs and wood sill plate shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet (1829 mm) on center. There shall be a minimum of two bolts per plate section with one bolt located not more than 12 inches (305 mm) or less than seven bolt diameters from each end of the plate section. In Seismic Design Categories D1 and D2, anchor bolts shall also be spaced at 6 feet (1829 mm) on center and located with 12 inches (305 mm) from the ends of the plate section at interior braced wall lines when required by Section R602.10.9 to be supported on a continous foundation. Bolts shall be at least 1/2 inch (12.7 mm) in diameter and shall extend a minimum of 7 inches (178 mm) into masonry or concrete. Interior bearing wall sole plates on monolithic slab foundations shall be positively anchored with approved fasteners. A nut and washer shall be tightened on each bolt to the plate. Sills and sole plates shall be protected against decay and termites wher required by Sections R318 and R319. Cold-formed steel framing systems shall be fastened to the wood sill plates or anchored directly to the foundation as required in Section R505.3.1 or R603.1.1. Exceptions: 1. Foundation anchor straps, space as required to provide equivalent anchorage to 1/2-inch-diameter (12.7 mm) anchor bolts. 2. Walls 24 inches total in length or shorter connecting offset braced wall panels shall be anchored to the foundation with a minimum of one anchor bolt located in the center third of the plate section and shall be attached to adjacent braced wall panels per Figure R602.10.5 at corners. 3. Walls 12 inches total length or shorter connecting offset braced wall panels shall be permitted to be connected to the foundation without anchor bolts. The wall shall be attached to adjacent braced wall panels per Figure 602.10.5. As amended by the City of Lee's Summit.
Correction

Codes Administration - 2003 IRC 407.1.7.3 - Foundation elevation. On graded sites, the top of any exterior foundation shall extend aboe the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus 2 percent. Alternate elevations are permitted sublect to the approval of the building official, provided it can be demonstrated tha required drainage to the point of discharge and away from the structure is provided at all locations on the site.
Correction

Codes Administration - 2003 IRC 405.1 - Concrete or masonry foundations. Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the area to be protected and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend at least 1 foot beyond the outside edge of the footing and 6 inches above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper, and the drainage tiles or perforated pipe shall be placed on a mimum of 2 inches of washed gravel or crushed rock at lease on sieve size larger than the tile joint openings or perforation and covered with not less than 6 inches of the same material.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $2,327.21 $2,327.21 Paid 04/26/2007
84 Water Meters $500.00 $500.00 Paid 04/26/2007
85 Water Taps $10,936.00 $10,936.00 Paid 04/26/2007
89 Sewer Tap Fees $1,560.00 $1,560.00 Paid 04/26/2007
91 EFHB Maybrook Water Shed $2,215.72 $2,215.72 Paid 04/26/2007
Right of Way Permit $35.00 $35.00 Paid 04/26/2007
0120 Building Permit Fee $24.38 $24.38 Paid 07/07/2009
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Failed 05/14/2007
Correction
Corrective Action Required
05/14/2007
R325 Premises Identification (IRC) PROPERTY TO BE IDENTIFIABLE FROM STREET FOR ALL INSPECTIONS
Footing Inspection - Residential Passed 05/14/2007
Correction
Resolved
05/14/2007
LSCO 7-920 Footing Reinforcement (IRC)
Correction
Resolved
05/14/2007
LSCO 7-921 Column Pad Reinforcement (IRC)
Correction
Resolved
05/14/2007
R403.1 Footing support (IRC)
Correction
Resolved
05/14/2007
R403.1.1 Minimum size of footings (IRC)
Correction
Resolved
05/14/2007
R403.1.4 Footing Depth (IRC)
Correction
Resolved
05/14/2007
NONE None STANDARD FOOTINGS CONTINUOUS JUMPS 1 PIER PER GARAGE 2 BSMT PADS ON END UNITS 1 BSMT PADS ON INTERIOR UNITS 1 BSMT GRADE BEAM EACH INTERIOR UNIT
Erosion Control Inspection Residential Failed 06/15/2007
Correction
Corrective Action Required
06/15/2007
LSCO 5029 XX Erosion Control INADEQUATE EROSION CONTROL. 2 DAYS TO COMPLY
Correction
Corrective Action Required
06/15/2007
LSCO5029XX2 Tracking Mud, Debris STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY
Electrical Service Inspection Not Ready 06/15/2007
Correction
Corrective Action Required
06/15/2007
E3507.1 System Service Ground (IRC) PEX PIPING USED FOR WATER SERVICE. ADDITIONAL GROUND ROD WILL BE REQUIRED.
Sewer Service Inspection - R Partial 06/15/2007
Correction
Partial Correction
06/15/2007
NONE None UNIT 801 APPROVED. UNITS 803 & 805 NOT INSPECTED.
Water Service Inspection - R Partial 06/15/2007
Correction
Partial Correction
06/15/2007
NONE None UNIT 801 APPROVED TO METER SITE. UNITS 803 & 805 NOT INSPECTED.
Sewer Service Inspection - Residential Request Complete 6/15/2007 6/15/2007 06/15/2007
Miscellaneous Inspection Passed 06/18/2007
Correction
Resolved
06/18/2007
R325 Premises Identification (IRC) PROPERTY TO BE IDENTIFIABLE FROM STREET FOR ALL INSPECTIONS
Erosion Control Inspection Residential Failed 06/18/2007
Correction
Corrective Action Required
06/18/2007
LSCO 5029 XX Erosion Control INADEQUATE EROSION CONTROL. 2 DAYS TO COMPLY
Correction
Corrective Action Required
06/18/2007
LSCO5029XX2 Tracking Mud, Debris STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY
Sewer Service Inspection - R Partial 06/18/2007
Correction
Partial Correction
06/18/2007
NONE None UNITS 801 & 803 APPROVED. UNITS 805 & 807 NOT INSPECTED.
Water Service Inspection - R Partial 06/18/2007
Correction
Partial Correction
06/18/2007
NONE None UNITS 801 & 803 APPROVED TO METER SITE. UNITS 805 & 807 NOT INSPECTED.
Sewer Service Inspection - Residential Request Complete 6/18/2007 6/18/2007 06/18/2007
Water Service Inspection - Residential Request Complete 6/18/2007 6/18/2007 06/18/2007
Water Service Inspection - R Partial 06/19/2007
Correction
Partial Correction
06/19/2007
NONE None UNITS 801 & 803 & 805 APPROVED TO METER SITE. UNIT 807 NOT INSPECTED.
Sewer Service Inspection - R Partial 06/19/2007
Correction
Partial Correction
06/19/2007
NONE None UNITS 801 & 803 & 805 APPROVED. UNIT 807 NOT INSPECTED.
Electrical Service Inspection Not Ready 06/19/2007
Correction
Corrective Action Required
06/19/2007
E3507.1 System Service Ground (IRC) PEX PIPING USED FOR WATER SERVICES. ADDITIONAL GROUND ROD WILL BE REQUIRED.
Sewer Service Inspection - Residential Request Complete 6/19/2007 6/19/2007 06/19/2007
Water Service Inspection - Residential Request Complete 6/19/2007 6/19/2007 06/19/2007
Erosion Control Inspection Residential Failed 06/20/2007
Underslab Plumbing Inspection - Residential Passed 06/20/2007
Sewer Service Inspection - R Partial 06/20/2007
Correction
Partial Correction
06/20/2007
NONE None UNITS 801 & 803 & 805 APPROVED. UNIT 807 APPROVED TO 15' FROM FOUNDATION
Water Service Inspection - R Partial 06/20/2007
Correction
Partial Correction
06/20/2007
NONE None UNIT 801 APPROVED. UNITS 803 & 805 APPROVED TO METER SITE. UNIT 807 NOT INSPECTED.
Water Service Inspection - R Partial 06/25/2007
Correction
Partial Correction
06/25/2007
NONE None UNITS 801 & 803 APPROVED. UNITS 805 & 807 APPROVED TO METER SITE.
Sewer Service Inspection - R Passed 06/25/2007
Correction
Resolved
06/25/2007
NONE None UNITS 801 & 803 & 805 & 807 APPROVED.
Water Service Inspection - Residential Request Complete 6/25/2007 6/25/2007 06/25/2007
Sewer Service Inspection - Residential Request Complete 6/25/2007 6/25/2007 06/25/2007
Erosion Control Inspection Residential Failed 10/05/2007
Correction
Corrective Action Required
10/05/2007
LSCO 5029 XX Erosion Control INADEQUATE EROSION CONTROL. 2 DAYS TO COMPLY
Correction
Resolved
10/05/2007
LSCO5029XX2 Tracking Mud, Debris
Electrical Service Inspection Failed 10/05/2007
Correction
Corrective Action Required
10/05/2007
E3507.1 System Service Ground (IRC) PEX PIPING USED FOR WATER SERVICES. ADDITIONAL GROUND ROD WILL BE REQUIRED. PROVIDE GROUND TO NEUTRAL JUMP AT MAIN SOURCE OF DISC. ENCLOSURE MAY NOT BE USED AS SYSTEM SERVICE GROUND OR GROUND - NEUTRAL JUMP
Correction
Corrective Action Required
10/05/2007
MISC PANEL BONDING Basement 801, 803, 805, 807
All Rough Inspection - Residential Failed 10/05/2007
Correction
Corrective Action Required
10/05/2007
R802.10 Roof Truss Design Drawings (IRC) PROVIDE ROOF TRUSS AND TJI DRAWINGS/SPECS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC FASTENING NAIL ALL CORNER STUDS PER IRC FASTENING SCHEDULE (2 #10'S EVERY 24" OR 1 #10 EVERY 12") THROUGHOUT 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC COMPLETE WATER PIPING Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC GAS PIPING GAS PIPING INSTALLATION INCOMPLETE AND NOT INSPECTED. SHEET ROCK NOT RECOMMENDED UNTIL AFTER GAS SERVICE IS APPROVED. 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC TALL WALL APPROVAL PROVIDE ENGINEER'S SEALED APPROVAL FOR CONSTRUCTION OF ALL WALLS OVER 10' 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC RECEPTACLE SPACING PROVIDE FLOOR RECEPTACLES AS NECESSARY IN LIVING ROOMS NEAR STAIR TO ACCOMPLISH MAX. 12' SPACING Living Room 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
R403.1.6 Foundation Anchor Bolts (IRC) PROVIDE MIN. 2 ANCHORS PER WALL & 6' SPACING MIN. THROUGHOUT. NOTE: SOME REAR & SIDE WALLS HAVE NO ANCHORS Garage 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
P2605.1 Piping Support (IRC) SUPPORT PVC PIPING AT MAX. 4' Attic Area 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC INSTALL FIRE PLACES Living Room 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
LSCO 7-905 Glazing at Hazardous Locations (IRC) WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED Living Room 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
E3702.1 Wiring Installation and Support (IRC) SECURE WIRING WITHIN 8" OF EXTERIOR LIGHT JUNCTION BOX Living Room 801 - 807
Correction
Corrective Action Required
10/05/2007
MISC FRAMING 3 STUDS REQUIRED IN CORNER Living Room 801
Correction
Corrective Action Required
10/05/2007
E3304.9 Prevent Physical Damage (IRC) PROVIDE NAIL GUARD AT WIRING WITHIN 1.25" OF NAILING SURFACE (NEAR STAIR BEHIND MASTER BATH) Living Room 801
Correction
Corrective Action Required
10/05/2007
P2603.2.1 Water/DWV Preotection Against Physical Damage (IRC) PROVIDE BOCA PLATE TO PROTECT 2" VENT THRU TOP PLATE (BOTH SIDES) Master Bedroom 801
Correction
Corrective Action Required
10/05/2007
LSCO 7-903 Bathroom ventilation (IRC) CONNECT EXHAUST FAN DUCT Master Bathroom 801
Correction
Corrective Action Required
10/05/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF FLUE CHASE Master Closet 801
Correction
Corrective Action Required
10/05/2007
E3304.9 Prevent Physical Damage (IRC) PROTECT WIRING WITHIN 6' OF ATTIC ACCESS Master Closet 801-807
Correction
Corrective Action Required
10/05/2007
LSCO 7-917 Dwelling Unit Separation (IRC) 1- NO ROOF OPENINGS W/IN 4' OF SEPARATION 2- MAX. 16" STUD SPACING EXCEEDED (BROKEN/REMOVED STUDS) 3- REPLACE BROKEN JUNCTION BOXES 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
R602.8 Fireblocking (IRC) FIRE BLOCK AT FLOOR AND CEILING LINES UNIT SEPARATION WALLS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
R502.6 Bearing (Joist/Beam Girder) (IRC) PLUMB AND ANCHOR POSTS. PROVIDE FULL BEARING STEEL SHIMS AT BEAM POCKETS. Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
E3702.1 Wiring Installation and Support (IRC) SECURE NM WIRING WITHIN 12" OF CEILING JUNCTION BOX (2-GANG) NEAR STAIR) Basement 801
Correction
Corrective Action Required
10/05/2007
MISC PROVIDE POWER TO FURNACE Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/05/2007
MISC COMBINATION WASTE/VENT AT NORTH FOUNDATION: TOILET PIPING MAY NOT BE USED AS A COMB. WASTE/VENT (FROM SHOWER) Basement 801
Correction
Corrective Action Required
10/05/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) REPLACE TJI WHERE FLANGE IS CUT AT 3"W OR REPAIR PER TJI MANUFACTURE (LETTER WILL BE REQUIRED) Garage 803
Correction
Corrective Action Required
10/05/2007
MISC COMBINATION WASTE/VENT TOILET PIPING NOT ALLOWED TO BE USED AS COMB. WASTE/VENT Garage 803 - 805
Correction
Corrective Action Required
10/05/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF DUCT/FLUE CHASE AND AT CEILING LINE OF SOFFITS Garage 803 - 805
Correction
Corrective Action Required
10/05/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) PROVIDE LETTER OF VERIFICATION FROM ENGINEERED LUMBER SUPPLIER THAT LSL RIM JOIST ABOVE NORTH WALL IS STILL GOOD AFTER PLUMBING PENETRATIONS Kitchen 803 - 805
Correction
Corrective Action Required
10/05/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATES. (2 AT EACH PENETRATION) Kitchen 803 - 805
Correction
Corrective Action Required
10/05/2007
E3702.1 Wiring Installation and Support (IRC) SECURE NM WIRING WITHIN 8" OF FIREPLACE J-BOX Living Room 803
Correction
Corrective Action Required
10/05/2007
LSCO 7-903 Bathroom ventilation (IRC) PROVIDE EXHAUST FAN DUCT 1/2 BATH BY ENTRY 803
Correction
Corrective Action Required
10/05/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATE (2 REQUIRED) 1/2 BATH BY ENTRY 803
Correction
Corrective Action Required
10/05/2007
R502.6 Bearing (Joist/Beam Girder) (IRC) COLUMN REQUIRED TO SUPPORT FLOOR CANTILEVER Stairway 803
Correction
Corrective Action Required
10/05/2007
M1501.3 CLothes Dryer Exhaust Duct Length Limitation (IRC) DRYER DUCT EXCEEDS ACCUMULATED MAX. 25' Attic Area 803 - 805
Correction
Corrective Action Required
10/05/2007
M1501.1 Clothes Dryer Exhaust--General (IRC) DRYER DUCT MUST BE RIGID METAL WITH SMOOTH INTERIOR Attic Area - SOFFIT 803 - 805
Correction
Corrective Action Required
10/05/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATES Master Bedroom & BATH 803 - 805
Correction
Corrective Action Required
10/05/2007
R602.8 Fireblocking (IRC) PROVIDE FLUE CHASE. FIRE BLOCK TOP AS REQUIRED. Closet (FRONT) 803 - 805
Correction
Corrective Action Required
10/05/2007
R807.1 Attic Access (IRC) PROVIDE ATTIC ACCESS 803 - 805
Correction
Corrective Action Required
10/05/2007
R502.6 Bearing (Joist/Beam Girder) (IRC) PROVIDE ADDITIONAL STUDS UNDER DOUBLED TJI/LVL NEAR WATER ENTRY Basement 803
Correction
Corrective Action Required
10/05/2007
M1601.3.2 Duct Support (IRC) SUPPORT FLEX. DUCT MAX. 5' O.C. WITH MIN. 1-1/2" STRAPS Attic Area 803 - 805
Correction
Corrective Action Required
10/05/2007
LSCO 7-903 Bathroom ventilation (IRC) CONNECT EXHAUST FAN DUCT Restroom 2ND FLOOR 805
Correction
Corrective Action Required
10/05/2007
R802.10.4 Roof Truss Alteration (IRC) PROVIDE LETTER OF APPROVAL FROM TRUSS MANUFACTURER FOR HOLE DRILLED THRU BOTTOM CHORD 2ND FL. FRONT CLOSET 805
Correction
Corrective Action Required
10/05/2007
E3702.1 Wiring Installation and Support (IRC) SECURE NM WIRING WITHIN 8" OF EXTERIOR LIGHT JUNCTION BOXES Garage 807
Correction
Corrective Action Required
10/05/2007
R317.1 Smoke Alarms (IRC) PROVIDE SMOKE DETECTOR IMMEDIATELY OUTSIDE ROOM FRONT BEDROOM 801 - 807
Correction
Corrective Action Required
10/05/2007
MISC FLUE CLEARANCE FLUE MAY NOT BE WITHIN 1" OF COMBUSTIBLE MATERIAL Master Closet 807
Correction
Corrective Action Required
10/05/2007
LSCO 7-911 Stair Profile (IRC) MIN. HEADROOM CLEARANCE OF 6'8" NOT MET Stairway TO BASEMENT 807
Correction
Corrective Action Required
10/05/2007
E3702.4 Wiring in Unfinished Basements (IRC) PROTECT SE CABLE UNDER TJI JOISTS Basement 807
Correction
Corrective Action Required
10/05/2007
MISC COMPLETE WIRING WIRING IN CEILING INCOMPLETE Basement 807
Correction
Corrective Action Required
10/05/2007
MISC COMBINATION WASTE/VENT WASTE FROM TOILETS NOT ALLOWED TO BE USED AS COMBINATION WASTE/VENT (FROM SHOWER) Basement 807
Correction
Corrective Action Required
10/05/2007
NONE None 801 - 803 - 805 - 807: DO NOT INSULATE 801 - 803 - 805 - 807: DO NOT ROCK
Erosion Control Inspection Residential Failed 10/18/2007
Correction
Corrective Action Required
10/18/2007
LSCO 5029 XX Erosion Control INADEQUATE EROSION CONTROL. 2 DAYS TO COMPLY
Correction
Corrective Action Required
10/18/2007
LSCO5029XX2 Tracking Mud, Debris STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY
Gas Piping Inspection - Residential Failed 10/18/2007
Correction
Corrective Action Required
10/18/2007
G2423.1 Gas Piping Support (IRC) SUPPORT GAS PIPING MAX. 8' SPACING NOTE: ALL OTHER UNITS APPROVED UNIT 805 - BASEMENT
Gas Service Inspection - Residential Passed 10/18/2007
Correction
Resolved
10/18/2007
NONE None ALL UNITS 3 APPLIANCES EACH
Gas Piping Inspection - Residential Passed 10/23/2007
Correction
Resolved
10/23/2007
G2423.1 Gas Piping Support (IRC)
All Rough Inspection - Residential Failed 10/23/2007
Correction
Corrective Action Required
10/23/2007
R802.10 Roof Truss Design Drawings (IRC) PROVIDE ROOF TRUSS AND TJI DRAWINGS/SPECS 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
MISC FASTENING
Correction
Corrective Action Required
10/23/2007
MISC COMPLETE WATER PIPING Basement 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
MISC GAS PIPING
Correction
Corrective Action Required
10/23/2007
MISC TALL WALL APPROVAL PROVIDE ENGINEER'S SEALED APPROVAL FOR CONSTRUCTION OF ALL WALLS OVER 10' 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/23/2007
MISC RECEPTACLE SPACING PROVIDE FLOOR RECEPTACLES AS NECESSARY IN LIVING ROOMS NEAR STAIR TO ACCOMPLISH MAX. 12' SPACING Living Room 801- 807
Correction
Corrective Action Required
10/23/2007
R403.1.6 Foundation Anchor Bolts (IRC) PROVIDE MIN. 2 ANCHORS PER WALL Garage 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
P2605.1 Piping Support (IRC)
Correction
Corrective Action Required
10/23/2007
MISC INSTALL FIRE PLACES 801: SECURE NM CABLE W/IN 8" OF F.P. CONNECTION & PROTECT AT PENETRATION 803: PROTECT NM AT PENETRATION Living Room 801 - 803
Correction
Corrective Action Required
10/23/2007
LSCO 7-905 Glazing at Hazardous Locations (IRC) WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED Living Room 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
E3702.1 Wiring Installation and Support (IRC)
Correction
Corrective Action Required
10/23/2007
MISC FRAMING 3 STUDS REQUIRED IN CORNER (FULL HEIGHT & LOAD BEARING) Living Room 801
Correction
Resolved
10/23/2007
E3304.9 Prevent Physical Damage (IRC)
Correction
Resolved
10/23/2007
P2603.2.1 Water/DWV Preotection Against Physical Damage (IRC)
Correction
Resolved
10/23/2007
LSCO 7-903 Bathroom ventilation (IRC)
Correction
Corrective Action Required
10/23/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF FLUE CHASE Master Closet 801
Correction
Corrective Action Required
10/23/2007
E3304.9 Prevent Physical Damage (IRC) PROTECT WIRING WITHIN 6' OF ATTIC ACCESS Master Closet 801-807
Correction
Corrective Action Required
10/23/2007
LSCO 7-917 Dwelling Unit Separation (IRC) 1- NO ROOF OPENINGS W/IN 4' OF SEPARATION 2- 3- REPLACE BROKEN JUNCTION BOXES 4- BETWEEN 801/803 & 805/807- REPAIR OR REPLACE OVERDRILLED STUDS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/23/2007
R602.8 Fireblocking (IRC) FIRE BLOCK AT FLOOR, CEILING & ATTIC LINES UNIT SEPARATION WALLS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/23/2007
R502.6 Bearing (Joist/Beam Girder) (IRC) PROVIDE FULL BEARING STEEL SHIMS AT BEAM POCKETS FULL WIDTH OF FLANGE. Basement 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
E3702.1 Wiring Installation and Support (IRC)
Correction
Corrective Action Required
10/23/2007
MISC PROVIDE POWER TO FURNACE NM WIRING TO BE PROTECTED WITH CONDUIT AND ADEQUATELY SUPPORTED & SECURED Basement 801 - 803 - 805 - 807
Correction
Resolved
10/23/2007
MISC COMBINATION WASTE/VENT
Correction
Corrective Action Required
10/23/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) REPLACE TJI WHERE FLANGE IS CUT AT 3"W OR REPAIR PER TJI MANUFACTURE (LETTER WILL BE REQUIRED) Garage 803
Correction
Corrective Action Required
10/23/2007
MISC COMBINATION WASTE/VENT TOILET PIPING NOT ALLOWED TO BE USED AS COMB. WASTE/VENT Garage 805
Correction
Corrective Action Required
10/23/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF DUCT/FLUE CHASE AND AT CEILING LINE OF SOFFITS ALSO, FIRE BLOCK AT HORIZONTAL TO VERTICAL CONNECTIONS IF PLYWOOD IS USED AT FIRE BLOCK, IT MUST BE MIN. 3/4" Garage 803 - 805
Correction
Corrective Action Required
10/23/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) PROVIDE LETTER OF VERIFICATION FROM ENGINEERED LUMBER SUPPLIER THAT LSL RIM JOIST ABOVE NORTH WALL IS STILL GOOD AFTER PLUMBING PENETRATIONS Kitchen 803 - 805
Correction
Corrective Action Required
10/23/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATES. (2 AT EACH PENETRATION) ALSO, TOP PLATE IS OVERDRILLED AT VACUUM PIPES Kitchen 803 - 805
Correction
Resolved
10/23/2007
E3702.1 Wiring Installation and Support (IRC)
Correction
Resolved
10/23/2007
LSCO 7-903 Bathroom ventilation (IRC)
Correction
Corrective Action Required
10/23/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATE (2 REQUIRED) 1/2 BATH BY ENTRY 803
Correction
Resolved
10/23/2007
R502.6 Bearing (Joist/Beam Girder) (IRC)
Correction
Resolved
10/23/2007
M1501.3 CLothes Dryer Exhaust Duct Length Limitation (IRC)
Correction
Resolved
10/23/2007
M1501.1 Clothes Dryer Exhaust--General (IRC)
Correction
Resolved
10/23/2007
R602.6.1 Top Plate Drilling & Notching (IRC)
Correction
Corrective Action Required
10/23/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF FLUE/DUCT CHASE Closet (FRONT) 803 - 805
Correction
Corrective Action Required
10/23/2007
R807.1 Attic Access (IRC) PROVIDE ATTIC ACCESS PROTECT WIRING WITHIN 6' - UNIT 803, 805 RELOCATE DUCTWORK FROM ACCESS PORTAL - UNIT 803 803 - 805
Correction
Resolved
10/23/2007
R502.6 Bearing (Joist/Beam Girder) (IRC)
Correction
Corrective Action Required
10/23/2007
M1601.3.2 Duct Support (IRC) DO NOT SUPPORT FLEX. DUCT WITH DRYER DUCT Attic Area 803 - 805
Correction
Resolved
10/23/2007
LSCO 7-903 Bathroom ventilation (IRC)
Correction
Corrective Action Required
10/23/2007
R802.10.4 Roof Truss Alteration (IRC) PROVIDE LETTER OF APPROVAL FROM TRUSS MANUFACTURER FOR HOLE DRILLED THRU BOTTOM CHORD 2ND FL. FRONT CLOSET 805
Correction
Resolved
10/23/2007
E3702.1 Wiring Installation and Support (IRC)
Correction
Resolved
10/23/2007
R317.1 Smoke Alarms (IRC)
Correction
Corrective Action Required
10/23/2007
MISC FLUE CLEARANCE FLUE MAY NOT BE WITHIN 1" OF COMBUSTIBLE MATERIAL Master Closet 807
Correction
Resolved
10/23/2007
LSCO 7-911 Stair Profile (IRC)
Correction
Corrective Action Required
10/23/2007
E3702.4 Wiring in Unfinished Basements (IRC) PROTECT SE CABLE UNDER TJI JOISTS Basement 807
Correction
Resolved
10/23/2007
MISC COMPLETE WIRING
Correction
Resolved
10/23/2007
MISC COMBINATION WASTE/VENT
Correction
Corrective Action Required
10/23/2007
NONE None 801 - 803 - 805 - 807: DO NOT INSULATE 801 - 803 - 805 - 807: DO NOT ROCK
Correction
Corrective Action Required
10/23/2007
R602.8 Fireblocking (IRC) FIRE BLOCK CEILING AT NAT. GAS PENETRATION TO FIRE PLACE Basement 801 - 803 - 805 - 807
Water Service Inspection - R Passed 10/24/2007
Correction
Resolved
10/24/2007
NONE None ALL UNITS APPROVED
Water Service Inspection - Residential Request Complete 10/24/2007 10/24/2007 10/24/2007
All Rough Inspection - Residential Failed 10/30/2007
Correction
Corrective Action Required
10/30/2007
R802.10 Roof Truss Design Drawings (IRC) (3) TJI JOISTS MISSING IN FRONT BASEMENT CEILING 801 - 807
Correction
Corrective Action Required
10/30/2007
MISC COMPLETE WATER PIPING Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/30/2007
MISC TALL WALL APPROVAL PROVIDE ENGINEER'S SEALED APPROVAL FOR CONSTRUCTION OF ALL WALLS OVER 10' 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/30/2007
MISC RECEPTACLE SPACING PROVIDE FLOOR RECEPTACLES AS NECESSARY IN LIVING ROOMS NEAR STAIR TO ACCOMPLISH MAX. 12' SPACING Living Room 801- 807
Correction
Corrective Action Required
10/30/2007
R403.1.6 Foundation Anchor Bolts (IRC) PROVIDE MIN. 2 ANCHORS PER WALL (NEXT TO GARAGE DOORS) Garage 801 - 803 - 805 - 807
Correction
Resolved
10/30/2007
MISC INSTALL FIRE PLACES
Correction
Corrective Action Required
10/30/2007
LSCO 7-905 Glazing at Hazardous Locations (IRC) WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED Living Room 801 - 803 - 805 - 807
Correction
Resolved
10/30/2007
MISC FRAMING
Correction
Corrective Action Required
10/30/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF FLUE CHASE Master Closet 801
Correction
Corrective Action Required
10/30/2007
E3304.9 Prevent Physical Damage (IRC) PROTECT WIRING WITHIN 6' OF ATTIC ACCESS Master Closet 801-807
Correction
Corrective Action Required
10/30/2007
LSCO 7-917 Dwelling Unit Separation (IRC) 1- NO ROOF OPENINGS W/IN 4' OF SEPARATION 2- 3- REPLACE BROKEN JUNCTION BOXES 4- BETWEEN 801/803 & 805/807- REPAIR OR REPLACE OVERDRILLED STUDS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/30/2007
R602.8 Fireblocking (IRC) FIRE BLOCK AT FLOOR, CEILING & ATTIC LINES UNIT SEPARATION WALLS 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/30/2007
R502.6 Bearing (Joist/Beam Girder) (IRC) PROVIDE FULL BEARING STEEL SHIMS AT BEAM POCKETS FULL WIDTH OF FLANGE. Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
10/30/2007
MISC PROVIDE POWER TO FURNACE NM WIRING TO BE PROTECTED WITH CONDUIT AND ADEQUATELY SUPPORTED & SECURED SUPPORT TOP OF CONDUIT Basement 805 - 807
Correction
Resolved
10/30/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) APPROVED PER TRUSS MANUFACTURER (ON FILE)
Correction
Resolved
10/30/2007
MISC COMBINATION WASTE/VENT
Correction
Corrective Action Required
10/30/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF DUCT/FLUE CHASE AND AT CEILING LINE OF SOFFITS ALSO, FIRE BLOCK AT HORIZONTAL TO VERTICAL CONNECTIONS IF PLYWOOD IS USED AT FIRE BLOCK, IT MUST BE MIN. 3/4" Garage 803 - 805
Correction
Resolved
10/30/2007
R502.8.2 Drilling & Notching (Engineered) (IRC) APPROVED PER TRUSS MANUFACTURER (ON FILE)
Correction
Corrective Action Required
10/30/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATES. (2 AT EACH PENETRATION) ALSO, TOP PLATE IS OVERDRILLED AT VACUUM PIPES Kitchen 803 - 805
Correction
Corrective Action Required
10/30/2007
R602.6.1 Top Plate Drilling & Notching (IRC) PROVIDE STRUCTURAL STRAPS AT OVERDRILLED TOP PLATE (2 REQUIRED) 1/2 BATH BY ENTRY 803
Correction
Corrective Action Required
10/30/2007
R602.8 Fireblocking (IRC) FIRE BLOCK TOP OF FLUE/DUCT CHASE (INCOMPLETE AT PIPE PENETRATIONS) Closet (FRONT 2ND FL) 803 - 805
Correction
Corrective Action Required
10/30/2007
R807.1 Attic Access (IRC) PROVIDE ATTIC ACCESS PROTECT WIRING WITHIN 6' - UNIT 803, 805 RELOCATE DUCTWORK FROM ACCESS PORTAL - UNIT 803 803 - 805
Correction
Corrective Action Required
10/30/2007
M1601.3.2 Duct Support (IRC) DO NOT SUPPORT FLEX. DUCT WITH DRYER DUCT (STILL TO BE SUPPORTED AT MAX. 5' SPACING W/ MIN. 1-1/2" STRAPS) Attic Area 803
Correction
Resolved
10/30/2007
R802.10.4 Roof Truss Alteration (IRC) APPROVED PER TRUSS MANUFACTURER (ON FILE)
Correction
Resolved
10/30/2007
MISC FLUE CLEARANCE
Correction
Resolved
10/30/2007
E3702.4 Wiring in Unfinished Basements (IRC)
Correction
Corrective Action Required
10/30/2007
R602.8 Fireblocking (IRC) FIRE BLOCK CEILING AT NAT. GAS PENETRATION TO FIRE PLACE Basement 801 - 803 - 805 - 807
All Rough Inspection - Residential Failed 11/06/2007
Correction
Corrective Action Required
11/06/2007
MISC COMPLETE WATER PIPING Basement 801 - 803 - 805 - 807
Correction
Corrective Action Required
11/06/2007
MISC TALL WALL APPROVAL PROVIDE ENGINEER'S SEALED APPROVAL FOR CONSTRUCTION OF ALL WALLS OVER 10' 801 - 803 - 805 - 807
Correction
Resolved
11/06/2007
MISC RECEPTACLE SPACING
Correction
Resolved
11/06/2007
R403.1.6 Foundation Anchor Bolts (IRC)
Correction
Corrective Action Required
11/06/2007
LSCO 7-905 Glazing at Hazardous Locations (IRC) WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED Living Room 801 - 803 - 805 - 807
Correction
Resolved
11/06/2007
R602.8 Fireblocking (IRC)
Correction
Corrective Action Required
11/06/2007
E3304.9 Prevent Physical Damage (IRC) PROTECT WIRING WITHIN 6' OF ATTIC ACCESS Master Closet 807
Correction
Resolved
11/06/2007
LSCO 7-917 Dwelling Unit Separation (IRC)
Correction
Corrective Action Required
11/06/2007
R602.8 Fireblocking (IRC) FIRE BLOCK AT FLOOR, CEILING & ATTIC LINES UNIT SEPARATION WALLS 801 - 803 - 805 - 807
Correction
Resolved
11/06/2007
R502.6 Bearing (Joist/Beam Girder) (IRC)
Correction
Resolved
11/06/2007
MISC PROVIDE POWER TO FURNACE
Correction
Resolved
11/06/2007
R602.8 Fireblocking (IRC)
Correction
Resolved
11/06/2007
R602.6.1 Top Plate Drilling & Notching (IRC)
Correction
Resolved
11/06/2007
R602.6.1 Top Plate Drilling & Notching (IRC)
Correction
Resolved
11/06/2007
R602.8 Fireblocking (IRC)
Correction
Corrective Action Required
11/06/2007
R807.1 Attic Access (IRC) PROVIDE ATTIC ACCESS PROTECT WIRING WITHIN 6' - UNIT 803, 805 803 - 805
Correction
Resolved
11/06/2007
M1601.3.2 Duct Support (IRC)
Correction
Corrective Action Required
11/06/2007
NONE None 801 - 803 - 805 - 807: OK TO INSULATE 801 - 803 - 805 - 807: DO NOT ROCK
Correction
Corrective Action Required
11/06/2007
R602.8 Fireblocking (IRC) FIRE BLOCK CEILING AT NAT. GAS PENETRATION TO FIRE PLACE Basement 801 - 803 - 805 - 807
Electrical Service Inspection Failed 11/06/2007
Correction
Resolved
11/06/2007
MISC PANEL BONDING
Electrical Service Inspection Passed 11/14/2007
Correction
Resolved
11/14/2007
E3507.1 System Service Ground (IRC)
All Rough Inspection - Residential Failed 11/14/2007
Correction
Resolved
11/14/2007
R802.10 Roof Truss Design Drawings (IRC) APPROVED PER LETTER DATED 11/7/07
Correction
Corrective Action Required
11/14/2007
MISC COMPLETE WATER PIPING Basement 801 - 803 - 805 - 807
Correction
Resolved
11/14/2007
MISC TALL WALL APPROVAL APPROVED PER LETTER DATED 11/7/07
Correction
Resolved
11/14/2007
E3304.9 Prevent Physical Damage (IRC)
Correction
Resolved
11/14/2007
R602.8 Fireblocking (IRC)
Correction
Resolved
11/14/2007
R807.1 Attic Access (IRC)
Correction
Partial Correction
11/14/2007
NONE None ALL UNITS: OK TO INSULATE OK TO ROCK (CONTINGENT UPON LEAVING OPEN SPACE FOR INSPECTION OF ATTIC SEPARATION)
Correction
Corrective Action Required
11/14/2007
R602.8 Fireblocking (IRC) FIRE BLOCK CEILING AT NAT. GAS PENETRATION TO FIRE PLACE Basement 801 - 803 - 805 - 807
All Rough Inspection - Residential Failed 11/29/2007
Correction
Corrective Action Required
11/29/2007
R602.8 Fireblocking (IRC) 1. FB GAPS AT TRUSSES, PVC LINES, HVAC VENTS 2. SEAL(WITH FIRETAPE) AT SEAMS. 807, 805, 803, 801 Attic Separartion
All Rough Inspection - Residential Failed 12/14/2007
Correction
Resolved
12/14/2007
R602.8 Fireblocking (IRC)
Driveway Inspection Passed 03/24/2008
Sidewalk Inspection Partial 04/16/2008
Erosion Control Inspection Residential Failed 04/29/2008
Correction
Corrective Action Required
04/29/2008
LSCO 5029 XX Erosion Control INADEQUATE EROSION CONTROL. NO FURTHER INSPECTIONS UNTIL COMPLIANT 2ND NOTICE
Correction
Corrective Action Required
04/29/2008
LSCO5029XX2 Tracking Mud, Debris STREET CLEANUP REQUIRED. CLEAN OUT STORM INLETS. NO FURTHER INSPECTIONS UNTIL COMPLIANT 2ND NOTICE
Erosion Control Inspection Residential Passed 07/25/2008
Correction
Resolved
07/25/2008
LSCO 5029 XX Erosion Control
Correction
Resolved
07/25/2008
LSCO5029XX2 Tracking Mud, Debris
All Rough Inspection - Residential Passed 07/25/2008
Correction
Resolved
07/25/2008
MISC COMPLETE WATER PIPING MOVED TO FINAL
Correction
Resolved
07/25/2008
LSCO 7-905 Glazing at Hazardous Locations (IRC) MOVED TO FINAL
Correction
Resolved
07/25/2008
NONE None ALL UNITS: OK TO INSULATE OK TO ROCK
Correction
Resolved
07/25/2008
R602.8 Fireblocking (IRC) MOVED TO FINAL
Occupancy Inspection - Codes Residential Failed 07/25/2008
Correction
Corrective Action Required
07/25/2008
MISC PROVIDE DECK PERMITS ALL UNITS
Correction
Corrective Action Required
07/25/2008
R401.3 Grading (IRC) GRADE AROUND WATER METERS TO COMPLETELY COVER BELL AND NOT BE ABLE TO HOLD WATER. REPAIR METER PIT AT UNIT 803. MAINTAIN 14-18" METER TO LID CLEARANCE. PROVIDE SPLASH BLOCK IN FRONT OF UNIT 807 (BY GARAGE) Exterior ALL UNITS
Correction
Corrective Action Required
07/25/2008
LSCO 7-216 Guards (IBC) GUARD AT FRONT PORCH NOT TO ALLOW PASSAGE OF 4" SPHERE Exterior UNIT 801
Correction
Corrective Action Required
07/25/2008
R321.3.1 Through Penetrations (IRC) CAULK/SEAL ALL EXTERIOR PENETRATIONS INCLUDING, BUT NOT LIMITED TO: - AROUND SCONCES - ABOVE A/C DISCONNECT SWITCHES - STUCCO PENETRATIONS - LOW VOLTAGE WIRING - NAT. GAS ENTRIES - AROUND FRONT GFCI RECEPTACLES Exterior ALL UNITS
Correction
Corrective Action Required
07/25/2008
MISC WIRING SUPPORT SECURE A/C CONDUIT TO STRUCTURE WITHIN 12" OF DISC. SWITCH Exterior ALL UNITS
Correction
Corrective Action Required
07/25/2008
MISC ELECTRICAL FINISH COMPLETELY INSTALL METER BOX COVER Exterior EAST
Correction
Corrective Action Required
07/25/2008
MISC LABEL GAS METERS PER UNIT Exterior EAST
Correction
Corrective Action Required
07/25/2008
LSCO 7-907 Garage Separation (IRC) PROVIDE FIRE CAULK IN CEILING PENETRATION AT OVERHEAD DOOR CONTROLS Garage 801, 803, 805, 807
Correction
Corrective Action Required
07/25/2008
MISC VOLTAGE SEPARATION PROVIDE PLATE TO SEPARATE 120V FROM 24V WIRING Living Room 801, 803, 805, 807
Correction
Corrective Action Required
07/25/2008
MISC CONDUCTOR PROXIMITY TO COMBUSTIBLES PROVIDE SPARK RING AT RECEPTACLE ABOVE FIRE PLACE Living Room 801, 807
Correction
Corrective Action Required
07/25/2008
MISC ISSUE FROM ALL-ROUGH FIRE BLOCK NAT. GAS PENETRATION UNDER FIRE PLACES Basement 801, 803, 805, 807
Correction
Corrective Action Required
07/25/2008
E3806.9 Outlet Box Covers & Faceplates (IRC) PROVIDE COVERPLATE AT RECEPTACLE NEAR STAIRS Basement UNIT 801
Correction
Corrective Action Required
07/25/2008
MISC PLUMBING FINISH SECURE BOTTOM OF PEX PIPING USED AS WATER HEATER P&T RELIEF (PER PEX MANUFACTURER'S INSTRUCTIONS - TO BE SUPPORTED MAX. 32" SPACING) Basement 801, 803, 805, 807
Correction
Corrective Action Required
07/25/2008
LSCO 7-914 Handrails (IRC) INSTALL HANDRAILS Stairway
Correction
Corrective Action Required
07/25/2008
E4109.3 Hydromassage Bathtub Access (IRC) MOTOR MUST BE ABLE TO BE REMOVED. PROVIDE ADDITIONAL OR LARGER ACCESS. Master Bathroom 803 & 805
Correction
Corrective Action Required
07/25/2008
MISC LIGHT FIXTURE REQUIREMENTS LIGHT FIXTURE MAY NOT BE INSTALLED WITHIN 12" OF SHELF Front Bedroom Closet UNIT 803
Correction
Corrective Action Required
07/25/2008
MISC OVERCURRENT PROTECTION A/C UNIT BREAKER OVERSIZED. REPLACE WITH 25-40 AMP Basement 803, 805
Correction
Corrective Action Required
07/25/2008
MISC STAIR PROFILE MAX. RISER TO BE 7-3/4". RISERS TO BE CONSISTENT WITHIN 3/8" Stairway TO BASEMENT 803, 805
Correction
Corrective Action Required
07/25/2008
MISC GFCI PROTECTION RECEPTACLE IN WALL SERVING HYDRO TUB NON-FUNCTIONAL. Master Bathroom
Correction
Corrective Action Required
07/25/2008
E4109.3 Hydromassage Bathtub Access (IRC) REMOVE ACCESS PANEL FOR INSPECTION. Master Bathroom UNIT 807
Correction
Corrective Action Required
07/25/2008
LSCO 7-914 Handrails (IRC) INSTALL HANDRAIL Stairway UNIT 807
Correction
Corrective Action Required
07/25/2008
E3806.9 Outlet Box Covers & Faceplates (IRC) COVER OPEN BLANKS IN PANEL Basement UNIT 807
Correction
Corrective Action Required
07/25/2008
NONE None NOTE: UNIT 801 OCCUPIED PRIOR TO APPROVAL. ALL SUBSEQUENT INSPECTIONS IN THIS UNIT REQUIRED TO BE ESCORTED. DO NOT OCCUPY ALL UNITS
Occupancy Inspection - Codes Residential Failed 08/22/2008
Correction
Resolved
08/22/2008
R401.3 Grading (IRC)
Correction
Resolved
08/22/2008
LSCO 7-216 Guards (IBC)
Correction
Resolved
08/22/2008
R321.3.1 Through Penetrations (IRC)
Correction
Resolved
08/22/2008
MISC WIRING SUPPORT
Correction
Resolved
08/22/2008
MISC ELECTRICAL FINISH
Correction
Resolved
08/22/2008
LSCO 7-907 Garage Separation (IRC)
Correction
Resolved
08/22/2008
MISC VOLTAGE SEPARATION
Correction
Resolved
08/22/2008
MISC CONDUCTOR PROXIMITY TO COMBUSTIBLES
Correction
Resolved
08/22/2008
MISC ISSUE FROM ALL-ROUGH
Correction
Resolved
08/22/2008
E3806.9 Outlet Box Covers & Faceplates (IRC)
Correction
Resolved
08/22/2008
MISC PLUMBING FINISH
Correction
Resolved
08/22/2008
LSCO 7-914 Handrails (IRC)
Correction
Resolved
08/22/2008
E4109.3 Hydromassage Bathtub Access (IRC)
Correction
Resolved
08/22/2008
MISC LIGHT FIXTURE REQUIREMENTS
Correction
Resolved
08/22/2008
MISC OVERCURRENT PROTECTION
Correction
Corrective Action Required
08/22/2008
MISC STAIR PROFILE MAX. RISER TO BE 7-3/4". RISERS TO BE CONSISTENT WITHIN 3/8" Stairway TO BASEMENT 803, 805
Correction
Resolved
08/22/2008
MISC GFCI PROTECTION
Correction
Resolved
08/22/2008
E4109.3 Hydromassage Bathtub Access (IRC)
Correction
Resolved
08/22/2008
LSCO 7-914 Handrails (IRC)
Correction
Resolved
08/22/2008
E3806.9 Outlet Box Covers & Faceplates (IRC)
Correction
Resolved
08/22/2008
NONE None
Occupancy Inspection - Codes Residential Failed 09/17/2008
Correction
Corrective Action Required
09/17/2008
MISC PROVIDE DECK PERMITS -SHALL SUBMIT A VACATION OF EASEMENT APPLICATION IN ORDER TO VACATE THE PORTION OF THE 30-FOOT EASEMENT ALONG THE REAR PROPERTY LINE. -SHALL SUBMIT A VARIANCE APPLICATION FOR THE ENCROACHMENT INTO THE 30-FOOT SETBACK. -OBTAIN PERMIT ALL UNITS
Correction
Resolved
09/17/2008
MISC LABEL GAS METERS PER UNIT
Correction
Corrective Action Required
09/17/2008
MISC STAIR PROFILE MAX. RISER TO BE 7-3/4". RISERS TO BE CONSISTENT WITHIN 3/8" Stairway TO BASEMENT 803, 805
Occupancy Inspection - Codes Residential Failed 05/19/2009
Occupancy Inspection - Codes Residential Failed 06/24/2009
Correction
Corrective Action Required
06/24/2009
MISC PROVIDE DECK PERMITS -OBTAIN PERMIT ALL UNITS
Occupancy Inspection - Codes Residential Passed 08/18/2009
Correction
Resolved
08/18/2009
MISC PROVIDE DECK PERMITS
Correction
Resolved
08/18/2009
MISC STAIR PROFILE
Sidewalk Inspection Passed 08/25/2009
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home