Summary
B0700502
Building Permit - Residential
Voided
NETTERVILLE ROBERT T & LINDA L
ADD/ALTER SINGLE FAMILY
HOME RENOVATIONS
03/16/2007
03/16/2007
09/12/2007
01/14/2008
Locations
Contacts
BOB NETTERVILLE, Address:3646 NE BEECHWOOD  
TOTAL HOME SERVICES, Address:1941 N 45TH  
BRICOBE MECHANICAL SERVICE CO, Address:2421 NE OLD PAINT RD  
SUMMIT ELECTRICAL & MECHANICAL LLC, Address:PO BOX 1573  
NETTERVILLE ROBERT T & LINDA L, Address:3646 NE BEECHWOOD DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 09/12/2007 10/29/2010
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - The holder of this permit agrees and understands that only persons authorized per LSCO 7-130 are permitted to perform electrical, plumbing or mechanical work authorized by this permit.
Correction

In a combined effort with both the R-4, and the R-7 School Districts the City of Lee's Summit is working together to educate the development community on a new program, the "Lee's Summit Voluntary Residential Development Surcharge". This is a program, which will help raise capital to build new schools for our community. Brochures are available at the front counter of both the Planning and Development and the Codes Administration departments. You can also find more information on the City of Lee's Summit web site at lees-summit.mo.us. (For more information please contact the Board of Education at 986-2400).
Correction

CA - The holder of this permit agrees and understands that the work authorized by this permit shall be performed in accordance with the 2003 International Residential Code as amended by Chapter 7 of the Lee's Summit Code of Ordinances.
Correction

All residential projects applied for after May 6, 2006 shall have a maximum stair rise of 7-3/4 inches and a minimum tread depth of 10". This project was applied for after May 6, 2006 and therefore must comply with this requirement.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-122 - Any excavation for foundations and/or footings of buildings and structures shall be backfilled within twenty-eight (28) days from the date of permit issuance unless otherwise approved by the building official.
Correction

CA - LSCO 7-128 (a)1 - Retaining walls which are over 4 feet in height measured from the bottom of the footing to the top of the wall of the wall shall be designed and sealed by a professional engineer or architect registered in the State of Missouri. In addition, the building official may waive the requirements for a permit or engineered drawings for walls over 4 feet in height if it is deemed unnecessary to require such submittals due to the location and type of wall to be installed.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-168 A - Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94; the concrete need not be on the job.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

CA - LSCO 7-930 - All dwellings shall have a controlled method of water disposal from the roofs that will collect and discharge all roof drainage to the ground at least 3 feet from the foundation walls or to an approved drainage system.
Correction

Codes Administration - 2003 IRC 311.5.2 - Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
Correction

Codes Administration - 2003 IRC 401.3 - Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation wall shall fall a minimum of 6 inches with the first 10 feet. Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be provided to ensure drainage away from the structure.
Correction

Codes Administration - 2003 IRC 403.1.6 - Foundation anchorage. When braced wall panels are supported directly on continous foundations, the wall wood sill plate or cold-formed steel bottom track shall be anchored to the foundation in accordance with this section. The wood sole plate at exterior walls in monolithic slabs and wood sill plate shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet (1829 mm) on center. There shall be a minimum of two bolts per plate section with one bolt located not more than 12 inches (305 mm) or less than seven bolt diameters from each end of the plate section. In Seismic Design Categories D1 and D2, anchor bolts shall also be spaced at 6 feet (1829 mm) on center and located with 12 inches (305 mm) from the ends of the plate section at interior braced wall lines when required by Section R602.10.9 to be supported on a continous foundation. Bolts shall be at least 1/2 inch (12.7 mm) in diameter and shall extend a minimum of 7 inches (178 mm) into masonry or concrete. Interior bearing wall sole plates on monolithic slab foundations shall be positively anchored with approved fasteners. A nut and washer shall be tightened on each bolt to the plate. Sills and sole plates shall be protected against decay and termites wher required by Sections R318 and R319. Cold-formed steel framing systems shall be fastened to the wood sill plates or anchored directly to the foundation as required in Section R505.3.1 or R603.1.1. Exceptions: 1. Foundation anchor straps, space as required to provide equivalent anchorage to 1/2-inch-diameter (12.7 mm) anchor bolts. 2. Walls 24 inches total in length or shorter connecting offset braced wall panels shall be anchored to the foundation with a minimum of one anchor bolt located in the center third of the plate section and shall be attached to adjacent braced wall panels per Figure R602.10.5 at corners. 3. Walls 12 inches total length or shorter connecting offset braced wall panels shall be permitted to be connected to the foundation without anchor bolts. The wall shall be attached to adjacent braced wall panels per Figure 602.10.5. As amended by the City of Lee's Summit.
Correction

Codes Administration - 2003 IRC 407.1.7.3 - Foundation elevation. On graded sites, the top of any exterior foundation shall extend aboe the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus 2 percent. Alternate elevations are permitted sublect to the approval of the building official, provided it can be demonstrated tha required drainage to the point of discharge and away from the structure is provided at all locations on the site.
Correction

Codes Administration - 2003 IRC 405.1 - Concrete or masonry foundations. Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the area to be protected and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend at least 1 foot beyond the outside edge of the footing and 6 inches above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper, and the drainage tiles or perforated pipe shall be placed on a mimum of 2 inches of washed gravel or crushed rock at lease on sieve size larger than the tile joint openings or perforation and covered with not less than 6 inches of the same material.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $95.93 $95.93 Paid 03/16/2007
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 04/10/2007
Correction
Corrective Action Required
04/10/2007
MISC TRIMMER STUD @ LEFT JAMB OF SOUTH WINDOW DISCONTINUOUS MUST BE ONE PIECE
Correction
Corrective Action Required
04/10/2007
MISC NUMBER OF JACK STUDS SUPPORTING HEADERS SEE IRC TABLES 502.5: (1) & (2) BLDG WIDTH / LOADS / SPAN NOT DOUBLED WHERE REQUIRED
Correction
Corrective Action Required
04/10/2007
MISC BEARING OF HEADERS ON JACK STUDS SHIM ALL TIGHT FOR SOLID BEARING MANY HAVE GAPS AT TOP OF JACK STUD
Correction
Corrective Action Required
04/10/2007
MISC GROUNDING ELECTRODE TERMINATION AT WATER LINE CLEAN PIPE UNDER CLAMP TO PROVIDE CLEAN TERMINATION
Correction
Corrective Action Required
04/10/2007
MISC CONTINUITY OF GROUNDING ELECTRODE CONDUCTOR NEC 250-50 SPLIT BOLT CONNECTOR NOT IRREVERSIBLE CONNECTION
Correction
Corrective Action Required
04/10/2007
MISC CONDITION OF FLOOR JOISTS SOME COMPLETELY SEVERED. REPLACE, SISTER, OR REINFORCE TO RESTORE STRENGTH TO FLOOR SYSTEM. CALL TO DISCUSS IF NECESSARY. SOME OVER-NOTCHED OR HOLES > 1/3 DEPTH OR
Correction
Corrective Action Required
04/10/2007
MISC INSTALLATION AND VENTING OF WATER HEATER MUST BE COMPLIANT WITH IFGC SECTION 503.6.4 WORK IN PROGRESS OFFSETS IN VENTING
Correction
Corrective Action Required
04/10/2007
MISC EXISTING MASONRY FIREPLACE PER BUILDING OWNER/PERMIT HOLDER. CONFORMANCE REQUIREMENTS FOR OPERATING FIREPLACE WILL THEN BE WAIVED. TO BE PERMANENTLY SEALED WITH GAS PIPING REMOVED
Correction
Corrective Action Required
04/10/2007
MISC PLUMBING VENT STACK INSTALLATION USE APPROVED 1/16" THICK HARDENED STEEL REINFORCING PLATES @ 16" MINIMUM LENGTH TO RESTORE CONTINUITY OF TOP PLATE AND TO PROTECT PVC PIPE FROM PENETRATION. TOP PLATE SEVERED NO SHIELD PLATING
Correction
Corrective Action Required
04/10/2007
MISC FLASHING AT TOP OF PROJECTING TRIM REQUIRED OVER ALL HORZIONTAL WINDOW / DOOR / FRIEZE TRIM EXCEPT IMMEDIATELY UNDER SOFFIT (W/I 1/2 OF SOFFIT PROJECTION)) NOT FOUND
All Rough Inspection - Residential Failed 04/26/2007
Correction
Resolved
04/26/2007
MISC TRIMMER STUD @ LEFT JAMB OF SOUTH WINDOW
Correction
Resolved
04/26/2007
MISC NUMBER OF JACK STUDS SUPPORTING HEADERS
Correction
Resolved
04/26/2007
MISC BEARING OF HEADERS ON JACK STUDS
Correction
Resolved
04/26/2007
MISC GROUNDING ELECTRODE TERMINATION AT WATER LINE
Correction
Resolved
04/26/2007
MISC CONTINUITY OF GROUNDING ELECTRODE CONDUCTOR
Correction
Resolved
04/26/2007
MISC CONDITION OF FLOOR JOISTS
Correction
Resolved
04/26/2007
MISC INSTALLATION AND VENTING OF WATER HEATER
Correction
Resolved
04/26/2007
MISC PLUMBING VENT STACK INSTALLATION
Correction
Partial Correction
04/26/2007
MISC ACCESSIBILITY OF ATTIC ACCESS MAY BE SAFETY HAZARD TO USER CAUTION TO PROPERTY OWNER LOCATION OF EXSTG ACCESS
Correction
Resolved
04/26/2007
MISC INSULATION & GYPSUM WALLBOARD WHEN READY OK TO INSULATE OK TO INSTALL GWB
Correction
Corrective Action Required
04/26/2007
MISC EXISTING STAIRWELL TO BASEMENT LACKS GUARD. HANDRAIL NOT FULL RUN OF STAIR. NON-CONFORMING CAUTION TO PROPERTY OWNER
Electrical Service Inspection Passed 04/26/2007
Correction
Resolved
04/26/2007
MISC ELECTRICAL SERVICE INSTALLATION RELEASE SERVICE
All Rough Inspection - Residential Failed 07/30/2007
Occupancy Inspection - Codes Residential Failed 08/01/2007
Correction
Corrective Action Required
08/01/2007
FD Approval Receive Fire Department approval IF QUESTIONS SEE REPORT PROVIDED CONTACT CPT JOE DIR
Correction
Resolved
08/01/2007
W/U Approval Receive Water Utilities Approval BACKFLOW PREVENTION DEVICE NOT REQUIRED DUE TO ANTICIPATED LOW USEAGE. NO ISSUES PRESENTLY DUE TO SMALL BUILDING
Correction
Corrective Action Required
08/01/2007
MISC FIXTURES IN RESTROOM WATER CLOSET MUST BE COMMERCIAL TYPE WITH ELONGATED BOWL AND OPEN FRONT SEAT. CAULK TO FLOOR. PROVIDE COMMERCIAL GRAB BARS PER ADA. NOT YET INSTALLED SUBJECT TO APPROVAL
Correction
Corrective Action Required
08/01/2007
MISC ELECTRICAL RECEPTACLE AT COFFEE COUNTER < 6' FROM SINK WALL NOT GFCI PROTECTED
Correction
Corrective Action Required
08/01/2007
MISC HOSE CONNECTION AT BASEMENT REQUIRES VACUUM BREAKER TO PREVENT BACKFLOW
Correction
Corrective Action Required
08/01/2007
MISC INSTALLATION OF FURNACE INSTALL VENT/INTAKE PIPING PER MANUFACTURER APPEARS INCOMPLETE PROVIDE MFGR INSTRUCTIONS
Correction
Corrective Action Required
08/01/2007
MISC USE / OCCUPANCY APPROVAL STATUS IBC 110.1: PRIOR TO APPROVAL DO NOT OCCUPY NOR PLACE PERSONAL PROPERTY
All Rough Inspection - Residential Passed 08/01/2007
Correction
Resolved
08/01/2007
MISC EXISTING MASONRY FIREPLACE SAFETY IS UNCERTAIN PROPERTY OWNER ENSURE FIREPLACE CANNOT BE USED
Correction
Resolved
08/01/2007
MISC FLASHING AT TOP OF PROJECTING TRIM REQUIREMENT WAVED TO AVOID DAMAGE TO SIDING
Correction
Resolved
08/01/2007
MISC ACCESSIBILITY OF ATTIC ACCESS NEW ACCESS HATCH INSTALLED AT RESTROOM
Correction
Resolved
08/01/2007
MISC EXISTING STAIRWELL TO BASEMENT LACKS GUARD. HANDRAIL NOT FULL RUN OF STAIR. NON-CONFORMING CAUTION TO PROPERTY OWNER
Occupancy Inspection - Codes Residential Failed 11/14/2007
Correction
Corrective Action Required
11/14/2007
MISC IDENTIFICATION OF CONTRACTORS NOT ON RECORD
Occupancy Inspection - Codes Residential Failed 11/14/2007
Occupancy Inspection - Codes Residential Not Ready 11/21/2007
Correction
Corrective Action Required
11/21/2007
FD Approval Receive Fire Department approval SEE REPORT PROVIDED CONTACT CPT JOE DIR
Correction
Corrective Action Required
11/21/2007
W/U Approval Receive Water Utilities Approval CONTACT BEN HASKAMP PHONE 816-969-1930
Correction
Corrective Action Required
11/21/2007
MISC FIXTURES IN RESTROOM PAD PIPING BELOW SINK & 42" MAX TO MIRROR BOTTOM
Correction
Corrective Action Required
11/21/2007
MISC HOSE CONNECTION AT BASEMENT ALSO, PROVIDE PRESSURE REGULATOR ON WATER SERVICE LINE REQUIRES VACUUM BREAKER TO PREVENT BACKFLOW
Correction
Corrective Action Required
11/21/2007
MISC IDENTIFICATION OF CONTRACTORS HVAC & PLUMBING MUST BE LICENSED
Correction
Corrective Action Required
11/21/2007
PW Approval Receive Public Works Approval CONTACT SHAWN GRAFF PHONE 816-969-1827
Correction
Corrective Action Required
11/21/2007
PD Approval Receive Planning & Development Approval CONTACT TOM SCANNELL PHONE 816-969-1603
Correction
Corrective Action Required
11/21/2007
MISC EVALUATION OF USE OF BUILDING FINAL INSPECTION TO FOLLOW RECEIPT AND ACCEPTANCE OF EVALUATION BY INDEPENDENT A/E. SUBMIT TO CODES ADMIN PREPARED BY LICENSED A/E
Correction
Corrective Action Required
11/21/2007
MISC ENTRANCE STEPS AT EAST ENTRANCE NO HANDRAILS PROVIDED
Correction
Corrective Action Required
11/21/2007
MISC EXPOSED NON-METALLIC ELECTRICAL CABLE SE EXTERIOR BLDG CORNER
Correction
Corrective Action Required
11/21/2007
MISC PENETRATIONS/HOLES IN EXTERIOR WALL IRC R703.1: SOUTH BUILDING WALL: SEAL HOLES / ANNULAR SPACES NOT SEALED PIPE, CONDUIT, CABLES#
Correction
Corrective Action Required
11/21/2007
MISC HANDICAPPED RAMP AT BUILDING EXTERIOR SLOPE, GUARD HEIGHT, ELEVATION TRANSITION TO GRADE SEE A/E EVALUATION RE ADA REQUIREMENTS
Correction
Corrective Action Required
11/21/2007
MISC HANDRAILS AT STEPS TO HANDICAPPED RAMP LANDING @ SE NOT INSTALLED
Correction
Corrective Action Required
11/21/2007
MISC STAIRS @ FRONT ENTRANCE E.G... HANDRAIL HEIGHT ABOVE TREAD NOSING 34" TO 38" MIN / MAX MUST COMPLY WITH IBC RE COMMERICIAL STAIRS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home