Permit Application Status

B0700091


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0700091
Building Permit - Commercial
Certificate of Occupancy
SAINT LUKES EAST HOSPITAL
NEW TENANT FINISH
TENANT FINISH
01/12/2007
02/27/2007
01/22/2008
07/30/2007
Locations
Contacts
ACI BOLAND, Address:11229 NALL SUITE 140  
A D JACOBSON CO INC, Address:16210 W 108TH ST  
A D JACOBSON CO INC, Address:16210 W 108TH ST  
A D JACOBSON CO INC, Address:16210 W 108TH ST  
A D JACOBSON CO INC, Address:16210 W 108TH ST  
JE DUNN, Address:929 HOLMES  
STACO ELECTRIC CONST. CO., INC., Address:3920 E. 137TH TERR  
SAINT LUKES EAST HOSPITAL, Address:100 NW SAINT LUKES BOULEVARD  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/16/2007 10/29/2010
Correction

CA - A Certificate of Occupancy will not be issued for a tenant finish until a minimum of a Temporary Occupancy has been issued for the shell building.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression system.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

Codes Administration - 2003 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Tale 403.1 shall be considered individually by the code official. The number of occupants shall be deetermined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-1300.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $6,531.01 $6,531.01 Paid 02/27/2007
89 Sewer Tap Fees $870.00 $870.00 Paid 02/27/2007
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Plumbing Inspection - Commercial Failed 04/10/2007
Correction
Corrective Action Required
04/10/2007
ADDITIONS/MODIFICATIONS TO ROOF DRAIN SYSTEM FIRST FLOOR LEVEL PORTIONS BELOW APPROVED:
Correction
Corrective Action Required
04/10/2007
ADDITIONS/MODIFICATIONS TO DWV SYSTEM FIRST FLOOR LEVEL PORTIONS BELOW APPROVED:
All Rough Inspection - Commercial Partial 04/27/2007
Correction
Partial Correction
04/27/2007
WALL FRAMING + IN-WALL SYSTEMS 219; 221; 224; 226; 231-264; 266; 268-274; 295-298; 299 N1/2; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
All Rough Inspection - Commercial Partial 05/04/2007
Correction
Partial Correction
05/04/2007
WALL FRAMING + IN-WALL SYSTEMS 212-213; 215-216; 218-219; 221; 224; 226; 227-228; 230; 231-264; 265; 266; 267; 268-274; 276-293; 295-299; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
All Rough Inspection - Commercial Partial 05/10/2007
Correction
Partial Correction
05/10/2007
WALL FRAMING + IN-WALL SYSTEMS 212-213; 215-216; 218-219; 221; 224; 226; 227-228; 230; 231-264; 265; 266; 267; 268-274; 276-293; 295-299; X-RAY ROOMS 220/223/225; 208 S WALL; 217; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Rated Assembly Inspection Partial 05/11/2007
Correction
Partial Correction
05/11/2007
UL RATED WALLS SPACE 242 ALL WALLS BOTH FACES; OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
All Rough Inspection - Commercial Partial 05/11/2007
Correction
Partial Correction
05/11/2007
WALL FRAMING + IN-WALL SYSTEMS 208 S WALL; 209-210-211; 212-213; 214; 215-228; 230-274; 276-293; 295-299; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Rough Framing Inspection - Commercial Request Complete 5/10/2007 5/11/2007 05/11/2007
All Rough Inspection - Commercial Partial 05/17/2007
Correction
Partial Correction
05/17/2007
WALL FRAMING + IN-WALL SYSTEMS 207E S&W WALLS; 208 S WALL; 209-228; X-RAY SHIELD WING WALL @ 220; 230-274; 275; 276-293; 295-299; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Rated Assembly Inspection Partial 05/21/2007
Correction
Partial Correction
05/21/2007
UL RATED WALLS 216; 242; 259 ALL WALLS BOTH FACES OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Above Ceiling Inspection Failed 06/12/2007
Correction
Partial Correction
06/12/2007
None RMS # - 2E225, 2E222, 2E223, 2E220 X-RAY ROOMS OK TO COVER
Above Ceiling Inspection Not Ready 06/18/2007
Correction
Corrective Action Required
06/18/2007
READINESS FOR INSPECTION HVAC DUCT AND INSULATION NOT COMPLETED WORK REQUESTED FOR INSP NOT COMPLETED
Correction
Partial Correction
06/18/2007
ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS 220; 222; 223; 225; OK TO COVER WHEN READY SPACES LISTED BELOW:
Correction
Resolved
06/18/2007
None
Above Ceiling Inspection Partial 06/29/2007
Correction
Resolved
06/29/2007
READINESS FOR INSPECTION
Correction
Partial Correction
06/29/2007
ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS ALL SPACES EXCEPT 260; 261 OK TO COVER WHEN READY SPACES LISTED BELOW:
Above Ceiling Inspection Passed 07/10/2007
Correction
Resolved
07/10/2007
ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS ALL SPACES INCLUDING 260; 261 OK TO COVER WHEN READY SPACES LISTED BELOW:
All Rough Inspection - Commercial Passed 07/10/2007
Correction
Resolved
07/10/2007
WALL FRAMING + IN-WALL SYSTEMS
Rated Assembly Inspection Passed 07/10/2007
Correction
Resolved
07/10/2007
UL RATED WALLS
Rough Plumbing Inspection - Commercial Passed 07/10/2007
Correction
Resolved
07/10/2007
ADDITIONS/MODIFICATIONS TO ROOF DRAIN SYSTEM
Correction
Resolved
07/10/2007
ADDITIONS/MODIFICATIONS TO DWV SYSTEM
Miscellaneous Inspection Passed 07/12/2007
Miscellaneous Inspection Passed 07/13/2007
Miscellaneous Inspection Partial 07/17/2007
Correction
Partial Correction
07/17/2007
PRE-FINAL INSPECTION/OBSERVATION
Erosion Control Inspection Residential Passed 07/17/2007
Miscellaneous Inspection Passed 07/19/2007
Correction
Resolved
07/19/2007
PRE-FINAL INSPECTION/OBSERVATION
Rough Framing Inspection - Commercial Passed 07/19/2007
Rough Framing Inspection - Commercial Request Complete 7/18/2007 7/19/2007 07/19/2007
Occupancy Inspection - Codes Commercial Failed 07/20/2007
Correction
Corrective Action Required
07/20/2007
LADDER TO ROOF LOW VOLTAGE CABLE INTERFERES W/ HANDHOLD
Correction
Corrective Action Required
07/20/2007
USE / OCCUPANCY APPROVAL STATUS IBC 110.1: PRIOR TO APPROVAL DO NOT OCCUPY NOR PLACE PERSONAL PROPERTY
Correction
Corrective Action Required
07/20/2007
UNUSED OPENING AT ELECT PANEL E2-4-LC NOT PLUGGED
Correction
Corrective Action Required
07/20/2007
CONDITION OF ROOF COVERING EAST / SOUTHEAST CORNER NOT ADHERED
Correction
Corrective Action Required
07/20/2007
CLEANING / CLEARING OF ROOFTOP REMOVE DEBRIS / MATERIAL ESPECIALLY METAL
Correction
Corrective Action Required
07/20/2007
EXTERIOR RECEPTACLES AT ROOF NOT HOT FOR TEST + ONE BROKEN COVER
Correction
Corrective Action Required
07/20/2007
CIRCUIT BREAKER POSITION NUMBERS NOT PERMANENT MARKED E2-4-LC; E2-7-LN
Correction
Corrective Action Required
07/20/2007
ELECTRICAL PANEL DP-E2-5-HA PLACE PERMANENT LABELS AT SWITCHES
Correction
Corrective Action Required
07/20/2007
ELECTRICAL PANEL DP-E2-10-XRAY PERMANENT SWITCH LABELS + LATCH NOT HOLDING
Correction
Corrective Action Required
07/20/2007
ELECTRICAL WALL BOXES SOME NOT CLOSED SPACES 275; 289; 293;...
Correction
Corrective Action Required
07/20/2007
BACKFLOW PREVENTION AT ICE MAKER(S) DEMONSTRATE DEVICE IN PLACE / LISTED
Correction
Corrective Action Required
07/20/2007
SMOKE DETECTOR DUST COVERS REMOVE PER FIRE DEPT
Correction
Corrective Action Required
07/20/2007
TESTING OF EMERGENCY ELECTRICAL CIRCUITS SCHEDULE TEST
Correction
Corrective Action Required
07/20/2007
RATED DOORS SMOKE SEALS + CLOSERS
Correction
Corrective Action Required
07/20/2007
SET-BACK OF ELECTRICAL RECEPTACLE/SWITCH BOXES CHECK ALL RESTROOMS & NURSE STATIONS FLUSH IN COMBUSTIBLE <= 1/4" @ NON-COMBUSTIBLE
Correction
Corrective Action Required
07/20/2007
Receive Fire Department approval
Occupancy Inspection - Codes Commercial Failed 07/23/2007
Occupancy Inspection - Codes Commercial Failed 07/23/2007
Correction
Corrective Action Required
07/23/2007
SET-BACK OF ELECTRICAL RECEPTACLE/SWITCH BOXES CHECK ALL NURSE STATIONS MUST BE FLUSH @ FACE IN COMBUSTIBLE SURFACES
Correction
Resolved
07/23/2007
RATED DOORS
Correction
Resolved
07/23/2007
SMOKE DETECTOR DUST COVERS
Correction
Resolved
07/23/2007
BACKFLOW PREVENTION AT ICE MAKER(S)
Correction
Resolved
07/23/2007
ELECTRICAL WALL BOXES
Correction
Resolved
07/23/2007
ELECTRICAL PANEL DP-E2-10-XRAY
Correction
Resolved
07/23/2007
ELECTRICAL PANEL DP-E2-5-HA
Correction
Resolved
07/23/2007
CIRCUIT BREAKER POSITION NUMBERS
Correction
Resolved
07/23/2007
EXTERIOR RECEPTACLES AT ROOF
Correction
Resolved
07/23/2007
CLEANING / CLEARING OF ROOFTOP
Correction
Resolved
07/23/2007
UNUSED OPENING AT ELECT PANEL E2-4-LC
Correction
Resolved
07/23/2007
LADDER TO ROOF
Occupancy Inspection - Codes Commercial Failed 07/24/2007
Occupancy Inspection - Codes Commercial Failed 07/25/2007
Correction
Resolved
07/25/2007
SET-BACK OF ELECTRICAL RECEPTACLE/SWITCH BOXES
Correction
Corrective Action Required
07/25/2007
INSTALLATION OF LIGHTED SIGN SUBJECT TO NATIONAL 2005 ELECTRICAL CODE. IF INTERNALLY LIGHTED, MUST BE UL SHOP-LABELED PER 600-3. INSTALL NO NON-LISTED SIGN. SUBJECT TO APPROVAL. PER NEC 600-3
Occupancy Inspection - Codes Commercial Passed 07/27/2007
Correction
Resolved
07/27/2007
Receive Fire Department approval PER JOE DIR 7/27/07
Correction
Resolved
07/27/2007
TESTING OF EMERGENCY ELECTRICAL CIRCUITS TESTED OK 7/27/07
Correction
Resolved
07/27/2007
CONDITION OF ROOF COVERING RESOLUTION IN PROGRESS BY JED + ROOFING CONTR
Correction
Resolved
07/27/2007
USE / OCCUPANCY APPROVAL STATUS
Correction
Resolved
07/27/2007
INSTALLATION OF LIGHTED SIGN SUBJECT TO NATIONAL 2005 ELECTRICAL CODE. IF INTERNALLY LIGHTED, MUST BE UL SHOP-LABELED PER 600-3. INSTALL NO NON-LISTED SIGN. P&D PERMIT REQUIRED PRIOR TO INSTALLATION
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home