Permit Application Status

B0603689


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0603689
Building Permit - Commercial
Certificate of Occupancy
HSM WDC PINETREE LLC
CHANGE OF TENANT
JAMES KOPPANG AGENCY TENANT FINISH
12/29/2006
01/22/2007
07/21/2007
03/07/2007
Locations
Contacts
JAMES KOPPANG AGENCY, Address:1320 NE WINDSOR DR  
HSM WDC PINETREE LLC, Address:12700 HILLCREST RD STE 125  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 07/18/2007 10/29/2010
Correction

Codes Administration - 2003 IBC 1109.4 - Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC A117.1.
Correction

Codes Administration - 2003 IBC 602.1 - General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. The building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire-resistance rating not less than that specified in Table 602.
Correction

Codes Administration - The project data indicates of zoning of GB for general business. The actual zoning of this property is CP-2.
Correction

Codes Administration - Information on the electrical and plumbing installation has not been provided.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor cove-ings, nor shall such cords be subject to environmental damage or physical impact.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IMC 602.2.1 - Materials exposed within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.5, materials exposed within plenums shall be noncombustible or shall have a flame spread index of not more than 25 and an smoke-developed index of not more than 50 when tested in accordance with ASTM E 84.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $81.70 $81.70 Paid 01/22/2007
89 Sewer Tap Fees $30.00 $30.00 Paid 01/22/2007
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Electrical Inspection - Commercial Failed 02/13/2007
Correction
Corrective Action Required
02/13/2007
IN-WALL ELECTRICAL -GROUND BOX OUTSIDE BATH
Correction
Corrective Action Required
02/13/2007
PATCH TENANT SEPARATION WALL HOLES/PENETRATIONS
Correction
Corrective Action Required
02/13/2007
ABOVE CEILING NOT READY FOR INSPECTION CALL FOR ABOVE CEILING WHEN READY, PROVIDE FULL VISUAL ACCESS NOTES: -NM CABLES NOT SECURELY FASTEN WITHIN 6 FT OF LUMINAIRES AND 12" OF ELECTRICAL BOXES -SUPPORT LUMINAIRES -BATHFAN NOT EXHAUST TO OUTSIDE -ETC
Rough Electrical Inspection - Commercial Failed 02/16/2007
Correction
Resolved
02/16/2007
IN-WALL ELECTRICAL
Correction
Resolved
02/16/2007
PATCH TENANT SEPARATION WALL HOLES/PENETRATIONS
Correction
Corrective Action Required
02/16/2007
ABOVE CEILING NOT READY FOR INSPECTION SUPPORT REQUIRED ON 2' X 4' LIGHTS IN CEILING.
Above Ceiling Inspection Failed 02/16/2007
Correction
Corrective Action Required
02/16/2007
None SUPPORT 2' X 4' LIGHT FIXTURES IN CEILING GRID.
Rough Electrical Inspection - Commercial Passed 02/23/2007
Correction
Resolved
02/23/2007
IN-WALL ELECTRICAL
Correction
Resolved
02/23/2007
PATCH TENANT SEPARATION WALL HOLES/PENETRATIONS
Correction
Resolved
02/23/2007
ABOVE CEILING NOT READY FOR INSPECTION
Above Ceiling Inspection Passed 02/23/2007
Correction
Resolved
02/23/2007
None RECOMMEND: 1) REMOVE FLAMABLE FACE OF ROOF INSULATION (SEE MANUFACTURER WARNING ON PAPER) 2) ENSURE ALL ELECTRICAL CABLE IN RETRUN AIR CEILING PLENUM IS PLENUM RATED. SEE RECOMMENDATIONS BELOW OK TO COVER WHEN READY
Occupancy Inspection - Codes Commercial Passed 03/06/2007
Correction
Resolved
03/06/2007
Receive Fire Department approval PER JOE DIR 3/6/07
Correction
Resolved
03/06/2007
CODES ADMINISTRATION FINAL INSPECTION NO ISSUES FOUND
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home