Summary
B0603213
Building Permit - Commercial
Final Completion
SNUGBEE LEES SUMMIT LLC
NEW SHELL BUILDING
NEW COMMERCIAL SHELL BUILDING
11/01/2006
02/08/2007
08/07/2007
08/29/2007
Locations
Contacts
HOLLIS & MILLER GROUP INC, Address:220 NW EXECUTIVE WAY  
UNITED HEATING & COOLING, Address:301 DUCK RD  
DAN HENRY CONSTRUCTION, Address:12302 JOHNSON DR  
MARTIN ELECTRIC LLC, Address:1542 E SPRUCE  
SCHOELLER PLUMBING INC, Address:1816 KATHLEEN WAY  
SNUGBEE LEES SUMMIT LLC, Address:7206 SILVER LODE LN  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 08/01/2007 10/29/2010
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the code official.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department- 907.12 Duct smoke detectors. Duct smoke detectors shall be connected to the building’s fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open area detection. Exceptions: 1. The supervisory signal at a constantly attended location is not required where duct smoke detectors activate the building’s alarm notification appliances. 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. 3. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

Codes Administration - The possible tenant address for this building are 1130, 1134, 1138 and 1142 NE Douglas St from south to north.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - Tenant finish plans shall be submitted to the Codes Administration Department prior to any interior alteration or improvments. Permits shall be obtained prior to any performing any work which requires permits.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

Lee's Summit Code of Ordinance - Sec.17-309 - Smoking. A. "No Smoking" signs or the international "No Smoking" symbol (consisting of a pictorial representation of a burning cigarette enclosed in a red circle with a red bar across it) shall be clearly and conspicicuously posted at every public place and place of emplyment where smoking is prohibited by this Article, by the owner, operator, manager, or other person in control of that place. B. Every public place and place of employment where smoking is prohibited by this Article shall have posted at every entrance a conspicuous sign clearly stating that smoking is prohibited.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $1,910.20 $1,910.20 Paid 02/08/2007
84 Water Meters $600.00 $600.00 Paid 02/08/2007
85 Water Taps $6,835.00 $6,835.00 Paid 02/08/2007
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Failed 03/05/2007
Correction
Corrective Action Required
03/05/2007
CONNECTION OF SE CONDUIT TO METER CABINET KNOCKOUT TEARING OUT CONNECTION NOT SECURE
Correction
Corrective Action Required
03/05/2007
RECEPTACLES ONE COVER MISSING + OPENINGS NOT PLUGGED
Correction
Corrective Action Required
03/05/2007
OPENINGS AT REAR OF PANEL BOARD ENCLOSURE NOT WEATHER-SEALED
Correction
Corrective Action Required
03/05/2007
MOUNTING OF PANEL BOARD TO POST NOT FULLY SECURED
Correction
Corrective Action Required
03/05/2007
SETTING OF MOUNTING POST NOT TAMPED-IN SOLID
Electrical Service Inspection Partial 03/08/2007
Correction
Partial Correction
03/08/2007
TEMPORARY ELECTRICAL SERVICE INSTALLATION 60 AMPS RELEASE SERVICE
Correction
Resolved
03/08/2007
CONNECTION OF SE CONDUIT TO METER CABINET
Correction
Resolved
03/08/2007
RECEPTACLES
Correction
Resolved
03/08/2007
OPENINGS AT REAR OF PANEL BOARD ENCLOSURE
Correction
Resolved
03/08/2007
MOUNTING OF PANEL BOARD TO POST
Correction
Resolved
03/08/2007
SETTING OF MOUNTING POST
Sewer Service Inspection Not Ready 03/09/2007
Correction
Corrective Action Required
03/09/2007
READINESS FOR INSPECTION REQUEST RE-SCHEDULED
Sewer Service Inspection Passed 03/12/2007
Correction
Resolved
03/12/2007
SANITARY SEWER SERVICE INSTALLATION FROM CONNECTION AT STUB TO 10'FROM BLDG ENTRY +CO
Correction
Resolved
03/12/2007
READINESS FOR INSPECTION
Sewer Service Inspection - Commercial Request Complete 3/9/2007 3/12/2007 03/12/2007
Water Service Inspection Passed 03/13/2007
Correction
Resolved
03/13/2007
WATER SERVICE INSTALLATION OK TO COVER WHEN READY FROM TAP; METER / PIT TO 5' FROM B/L
Water Service Inspection - Commercial Request Complete 3/13/2007 3/13/2007 03/13/2007
Footing Inspection - Commercial Partial 03/27/2007
Correction
Partial Correction
03/27/2007
PERIMETER GRADE BEAM + INTEGRAL COLUMN FOOTINGS STUB FOOTING GROUND JUMPER TO ABOVE POUR OK TO POUR WHEN READY ENTIRE PERIMETER
Water Service Inspection Partial 04/02/2007
Correction
Corrective Action Required
04/02/2007
WATER SERVICE INSTALLATION OK FROM TAP; METER / PIT TO 5' FROM B/L KINKED AT BUILDING ENTRY REPLACE BAD SECTION
Underground Plumbing Inspection - Commercial Passed 04/02/2007
Correction
Resolved
04/02/2007
INSTALLATION OF BUILDING DRAIN LINE OK TO COVER WHEN READY W/ CLEANOUTS & STUB-UPS AT EACH PLANNED SUITE
Water Service Inspection Passed 04/09/2007
Correction
Resolved
04/09/2007
WATER SERVICE INSTALLATION OK FROM TAP; METER / PIT TO 5' FROM B/L; ENTRY INTO BUILDING KINKED SECTION REPLACED OK TO COVER WHEN READY
Water Service Inspection - Commercial Request Complete 4/9/2007 4/9/2007 04/09/2007
Underground Electrical Inspection - Commercial Partial 04/17/2007
Correction
Partial Correction
04/17/2007
BURIED CONDUIT FOR SITE ELECTRICAL TWO E-W TRENCH RUNS FOR MONUMENT SIGN + 2 L.P.'S NEAR S PROP LINE; OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Underground Electrical Inspection - Commercial Request Complete 4/17/2007 4/17/2007 04/17/2007
Underground Electrical Inspection - Commercial Partial 04/19/2007
Correction
Partial Correction
04/19/2007
BURIED CONDUIT FOR SITE ELECTRICAL TWO E-W TRENCH RUNS FOR MONUMENT SIGN + 2 L.P.'S NEAR S PROP LINE; 2 BOLLARD LIGHTS @ SE BLDG CORNER; 2 L.P.'S @ N PROP LINE; FROM S.E. CORNER TO N.E. CORNER OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Underground Electrical Inspection - Commercial Request Complete 4/18/2007 4/19/2007 04/19/2007
Underground Electrical Inspection - Commercial Request Complete 4/19/2007 4/19/2007 04/19/2007
Underground Electrical Inspection - Commercial Partial 05/18/2007
Correction
Partial Correction
05/18/2007
BURIED CONDUIT FOR SITE ELECTRICAL TWO E-W TRENCH RUNS FOR MONUMENT SIGN + 2 L.P.'S NEAR S PROP LINE; 2 BOLLARD LIGHTS @ SE BLDG CORNER; 2 L.P.'S @ N PROP LINE; FROM S.E. CORNER TO N.E. CORNER; FINAL 12' FEEDING MONUMENT SIGN OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Underground Electrical Inspection - Commercial Request Complete 5/18/2007 5/18/2007 05/18/2007
Underslab Electrical Inspection - Commercial Passed 05/24/2007
Correction
Resolved
05/24/2007
UNDER-FLOOR ELECTRICAL CONDUIT OK TO COVER WHEN READY MATERIAL & WORKMANSHIP NO ISSUES FOUND
Underground Electrical Inspection - Commercial Partial 05/24/2007
Correction
Partial Correction
05/24/2007
BURIED CONDUIT FOR SITE ELECTRICAL TWO E-W TRENCH RUNS FOR MONUMENT SIGN + 2 L.P.'S NEAR S PROP LINE; 2 BOLLARD LIGHTS @ SE BLDG CORNER; 2 L.P.'S @ N PROP LINE; FROM S.E. CORNER TO N.E. CORNER; FINAL 12' FEEDING MONUMENT SIGN; L.P. FEEDERS COMPLETE WEST OF BLDG OK TO COVER WHEN READY PORTIONS LISTED BELOW:
Underground Electrical Inspection - Commercial Request Complete 5/24/2007 5/24/2007 05/24/2007
Underslab Plumbing Inspection - Commercial Partial 06/13/2007
Correction
Partial Correction
06/13/2007
None CONTRACTOR HAS INSTALLED PIPING FOR BATHROOMS, SERVICE SINK ON THE EAST SIDE OF STORE AND THE CLEANOUT ON THE EAST SIDE OF STORE *CONTRACTOR STATED THAT SUBWAY'S PERMIT WILL INCLUDE UTILITY AND GREASE TRAP* SUBWAY FINISH OK TO POUR
All Rough Inspection - Commercial Partial 06/26/2007
Correction
Partial Correction
06/26/2007
WALL FRAMING + IN-WALL SYSTEMS STARBUCKS (SOUTHERNMOST) SUITE {NORTH WALL INSIDE FACE ONLY}; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Rated Assembly Inspection Partial 06/28/2007
Correction
Partial Correction
06/28/2007
UL 412 RATED NORTH WALL OF STARBUCKS SUITE SOUTH FACE 1ST LAYER; OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Rated Assembly Inspection Partial 07/05/2007
Correction
Partial Correction
07/05/2007
UL 412 RATED NORTH WALL OF STARBUCKS SUITE SOUTH FACE 1ST LAYER; SOUTH FACE 2ND LAYER OK TO TAPE, MUD, AND FIRE-BLOCK OK TO COVER WHEN READY COMPONENTS LISTED BELOW:
Gas Piping Inspection - Commercial Passed 07/05/2007
Correction
Resolved
07/05/2007
VISUAL INSPECTION OF PIPING PIPING COMPLETE TO RTU-1; RTU-2; RTU-4; RTU-4; RTU-5 + STUBS FROM ROOF DOWN INTO SUITES FOR STARBUCKS AND SUBWAY EXTENT IN PLACE PRESENTLY SCOPE OF SHELL PERMIT
Gas Service Inspection - Commercial Partial 07/05/2007
Correction
Partial Correction
07/05/2007
PRESSURE TEST ON PIPING TO RTU-1; RTU-2; RTU-3; RTU-4; RTU-5 PRESSURE TEST APPROVED ON RTU-1; RTU-2; RTU-4; RTU-5, BUT NOT TO BE RELEASED UNTIL TENANT FINISH WORK PROCEEDS AND RELEASE IS REQUESTED AND APPROVED. PIPING FOR RTU-3 NOT READY FOR PRESSURE TEST. HELD STEADY AT >= 10 PSI FOR >=10 MIN
Underground Electrical Inspection - Commercial Partial 07/10/2007
Correction
Partial Correction
07/10/2007
PREP TO POUR CONCRETE LIGHT POLE BASES #3; 4; 5; OK TO POUR WHEN READY FOLLOWING L.P. BASES:
Correction
Corrective Action Required
07/10/2007
GROUNDING OF SITE LIGHT POLES NOT READY FOR INSPECTION
Underground Electrical Inspection - Commercial Request Complete 7/10/2007 7/10/2007 07/10/2007
Underground Electrical Inspection - Commercial Partial 07/12/2007
Correction
Resolved
07/12/2007
BURIED CONDUIT FOR SITE ELECTRICAL
Correction
Resolved
07/12/2007
PREP TO POUR CONCRETE LIGHT POLE BASES #1; 2; 3; 4; 5; 6;7 OK TO POUR WHEN READY FOLLOWING L.P. BASES:
Underground Electrical Inspection - Commercial Request Complete 7/12/2007 7/12/2007 07/12/2007
All Rough Inspection - Commercial Partial 07/18/2007
Correction
Partial Correction
07/18/2007
WALL FRAMING + IN-WALL SYSTEMS STARBUCKS SUITE PERIMETER WALLS; SUBWAY SUITE EAST & WEST WALLS + IN-WALL ELECTRICAL ONLY @ RESTROOMS; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Rated Assembly Inspection Partial 07/19/2007
Correction
Resolved
07/19/2007
UL 412 RATED NORTH WALL OF STARBUCKS SUITE
Correction
Partial Correction
07/19/2007
UL 412 RATED WALLS IN SUBWAY SUITE NORTH & SOUTH DEMISING WALLS 1ST LAYER 5/8" TYPE X GWB; OK TO COVER WHEN READY COMPONENTS LISTED BELOW
Underground Electrical Inspection - Commercial Partial 07/19/2007
Correction
Resolved
07/19/2007
BURIED CONDUIT & BOXES FOR DIRECTIONAL SIGNS OK TO COVER WHEN READY
Rated Assembly Inspection Passed 07/20/2007
Correction
Resolved
07/20/2007
UL 412 RATED WALLS IN SUBWAY SUITE 2ND LAYER 5/8" TYPE X GWB OK TO TAPE/MUD/FIRE-CAULK
Rough Plumbing Inspection - Commercial Not Ready 07/20/2007
Correction
Corrective Action Required
07/20/2007
READINESS FOR INSPECTION CALL FOR INSPECTION AFTER PREPARATION IS COMPLETE WORK REQUESTED FOR INSP NOT COMPLETED
All Rough Inspection - Commercial Failed 07/23/2007
Correction
Corrective Action Required
07/23/2007
PROTECTION OF COPPER & PVC PIPING FROM PENETRATION IPC 305.8: HARDENED STEEL PLATES PER CODE < 1-1/2" FROM FACE OF STUDS / TRACKS
All Rough Inspection - Commercial Partial 07/24/2007
Correction
Partial Correction
07/24/2007
WALL FRAMING + IN-WALL SYSTEMS STARBUCKS SUITE PERIMETER WALLS; SUBWAY SUITE EAST & WEST WALLS; + IN-WALL + ABOVE-CEILING @ SUBWAY SUITE RESTROOMS; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Correction
Resolved
07/24/2007
PROTECTION OF COPPER & PVC PIPING FROM PENETRATION
Underground Electrical Inspection - Commercial Passed 07/25/2007
Correction
Resolved
07/25/2007
GROUNDING OF SITE LIGHT POLES AT SEVEN POLES OK TO COVER WHEN READY
Footing Inspection - Commercial Passed 07/25/2007
Correction
Resolved
07/25/2007
PERIMETER GRADE BEAM + INTEGRAL COLUMN FOOTINGS
Underslab Plumbing Inspection - Commercial Passed 07/25/2007
Correction
Resolved
07/25/2007
None
Rough Plumbing Inspection - Commercial Passed 07/25/2007
Correction
Resolved
07/25/2007
READINESS FOR INSPECTION
Underground Electrical Inspection - Commercial Request Complete 7/25/2007 7/25/2007 07/25/2007
Gas Service Inspection - Commercial Partial 07/30/2007
Correction
Partial Correction
07/30/2007
PRESSURE TEST ON PIPING TO RTU-1; RTU-2; RTU-3; RTU-4; RTU-5 PRESSURE TEST APPROVED ON RTU-1; RTU-2; RTU-3; RTU-4; RTU-5, BUT NO SERVICES TO BE RELEASED UNTIL STARBUCKS ADDRESS # IS CONFIRMED AND RELEASE IS REQUESTED AND APPROVED FOR THAT SUITE SERVICE ONLY. HELD STEADY AT >= 10 PSI FOR >=10 MIN
Gas Piping Inspection - Commercial Passed 07/30/2007
Gas Service Inspection - Commercial Passed 08/01/2007
Correction
Resolved
08/01/2007
PRESSURE TEST ON PIPING TO RTU-1; RTU-2; RTU-3; RTU-4; RTU-5 RELEASE SERVICE FOR STARBUCKS SUITE 1130 ONLY PRESS TEST APPROVED PIPING TO FIVE RTU'S
All Rough Inspection - Commercial Partial 08/01/2007
Correction
Partial Correction
08/01/2007
WALL FRAMING + IN-WALL SYSTEMS STARBUCKS SUITE PERIMETER WALLS; SUBWAY SUITE EAST & WEST WALLS; + IN-WALL + ABOVE-CEILING @ SUBWAY SUITE RESTROOMS; SPACE 102/102A EAST & SOUTH WALLS ONLY; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Correction
Corrective Action Required
08/01/2007
STUDS CUT AT 102/102A NORTHWEST FOR COPPER PIPING REINFORCE STUDS @ CUTS
Correction
Corrective Action Required
08/01/2007
ISOLATION OF COPPER PIPING & STEEL STUDS SPACE 102/102A NORTHWEST ISOLATE DISSIMILAR METALS
Correction
Corrective Action Required
08/01/2007
MOUNTING ELECTRICAL BOXES TO FULL DEPTH OF WALLS SPACE 102/102A N&W WALLS EXTEND STAND-OFFS
Rough Electrical Inspection - Commercial Passed 08/02/2007
All Rough Inspection - Commercial Partial 08/02/2007
Correction
Partial Correction
08/02/2007
WALL FRAMING + IN-WALL SYSTEMS STARBUCKS SUITE PERIMETER WALLS; SUBWAY SUITE EAST & WEST WALLS; + IN-WALL + ABOVE-CEILING @ SUBWAY SUITE RESTROOMS; SPACE 102/102A PERIMETER WALLS COMPLETE EXCEPT 4' AT NW CORNER; OK TO COVER WHEN READY WALLS@SPACES LISTED BELOW
Correction
Resolved
08/02/2007
MOUNTING ELECTRICAL BOXES
Rated Assembly Inspection Partial 08/06/2007
Correction
Partial Correction
08/06/2007
UL 412 RATED SOUTH DEMISING WALL IN 102/102A OK TO COVER WHEN READY 1ST LAYER 5/8" TYPE X GWB
Electrical Service Inspection Partial 08/08/2007
Correction
Resolved
08/08/2007
TEMPORARY ELECTRICAL SERVICE INSTALLATION
Correction
Resolved
08/08/2007
CONNECTION OF PRIMARY TO BUILDING SERVICE EQUIPMENT OK TO SCHEDULE W/ AQUILA
Correction
Partial Correction
08/08/2007
ELECTRICAL SERVICE INSTALLATION SUITE 1130 (STARBUCKS) ONLY; RELEASE SERVICE AT METERS LISTED BELOW:
All Rough Inspection - Commercial Passed 08/08/2007
Correction
Resolved
08/08/2007
WALL FRAMING + IN-WALL SYSTEMS
Correction
Resolved
08/08/2007
STUDS CUT AT 102/102A NORTHWEST
Correction
Resolved
08/08/2007
ISOLATION OF COPPER PIPING & STEEL STUDS
Electrical Service Inspection Passed 08/10/2007
Correction
Resolved
08/10/2007
ELECTRICAL SERVICE INSTALLATION 1130H (HOUSE); SUITE 1130 (STARBUCKS); 1134 (SUBWAY) ; 1138 (FUTURE); 1142 (FUTURE) RELEASE SERVICE AT METERS LISTED BELOW:
Electrical Service Inspection Passed 08/10/2007
Correction
Resolved
08/10/2007
ELECTRICAL SERVICE INSTALLATION 1130H (HOUSE); SUITE 1130 (STARBUCKS); 1134 (SUBWAY) RELEASE SERVICES AT METERS LISTED BELOW:
Electrical Service Inspection Passed 08/13/2007
Correction
Resolved
08/13/2007
ELECTRICAL SERVICE INSTALLATION RELEASE SERVICE 1130H (HOUSE)
Rated Assembly Inspection Passed 08/14/2007
Correction
Resolved
08/14/2007
UL 412 RATED WALLS IN SUBWAY SUITE 2ND LAYER 5/8" TYPE X GWB
Correction
Resolved
08/14/2007
UL 412 RATED SOUTH DEMISING WALL IN 102/102A OK TO TAPE/MUD/FIRE-CAULK OK TO COVER WHEN READY 2 LAYERS 5/8" TYPE X GWB
Electrical Service Inspection Passed 08/15/2007
Correction
Resolved
08/15/2007
CONNECTION OF PRIMARY TO BUILDING SERVICE EQUIPMENT
Correction
Resolved
08/15/2007
ELECTRICAL SERVICE INSTALLATION 1142 RELEASE SERVICE 1130H (HOUSE)
Occupancy Inspection - Codes Commercial Failed 08/23/2007
Correction
Corrective Action Required
08/23/2007
Receive Fire Department approval
Correction
Corrective Action Required
08/23/2007
EXTERIOR LABLE GAS METERS
Correction
Corrective Action Required
08/23/2007
Receive Water Utilities Approval
Correction
Corrective Action Required
08/23/2007
Receive Planning & Development Approval
Correction
Corrective Action Required
08/23/2007
Receive Public Works Approval
Occupancy Inspection - Codes Commercial Failed 08/27/2007
Correction
Resolved
08/27/2007
Receive Planning & Development Approval OK PER T SCANNELL 8/23/07
Occupancy Inspection - Codes Commercial Passed 08/28/2007
Correction
Resolved
08/28/2007
Receive Water Utilities Approval PER BEN HASKAMP 8/27/07
Correction
Resolved
08/28/2007
Receive Public Works Approval PER RAY SCHICK 8/28/07
Correction
Resolved
08/28/2007
Receive Fire Department approval PER MARK HARDING
Correction
Resolved
08/28/2007
EXTERIOR
Final Inspection - Commercial Passed 08/28/2007
Correction
Resolved
08/28/2007
CLOSE SHELL PERMIT
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home