Summary
B0600759
Building Permit - Commercial
Certificate of Occupancy
REORGANIZED SCHOOL DIST NO 7
ADDITION COMMERCIAL
TITAN ATHLETIC COMPLEX ADDITION
05/15/2006
07/03/2006
12/30/2006
11/22/2006
Locations
Contacts
BRUNER CONTRACTING CO LLC, Address:218 DELAWARE ST STE 211  
DLR GROUP, Address:7421 W 129TH STREET SUITE 100  
DLR GROUP, Address:7421 W 129TH STREET SUITE 100  
DLR GROUP, Address:7290 W 133RD ST  
DLR GROUP, Address:7290 W 133RD ST  
REORGANIZED SCHOOL DIST NO 7, Address:301 NE Tudor Rd, Phone:(816) 986-1000  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/20/2006 10/29/2010
Correction

Fire Department- 907.3 Where required—retroactive in existing buildings and structures. An approved manual, automatic or manual and automatic fire alarm system shall be installed in existing buildings and structures in accordance with Sections 907.3.1 through 907.3.1.8. Where automatic sprinkler protection is provided in accordance with Section 903.3.1.1 or 903.3.1.2 and connected to the building fire alarm system, automatic heat detection required by this section shall not be required.
Correction

Codes Administration - The existing building was classified as a type B Occupancy. This application has the building classifed as an E Occupancy.
Correction

Codes Administration - The existing building was classified as a Type VB construction. This application has the building classifed as an Type IIIB construction.
Correction

Codes Administration - 2003 IBC 1006.1 - Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Codes Administration - Copies of the engineered truss package were not provided at the time of permit application.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; Required means of egress components shall be maintained during construction and demolition.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - All exterior mechanical equipment, whether roof mounted or ground mounted, shall be screened from view from off the property. The appearance of screens shall be coordinated with the building to maintain a unified appearance.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $2,224.03 $2,224.03 Paid 07/03/2006
89 Sewer Tap Fees $60.00 $60.00 Paid 07/03/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Failed 07/24/2006
Correction
Partial Correction
07/24/2006
Footing support (IRC) PER CHANGES ON SHOP DRAWINGS - SEND CHANGES TO OFFICE RM 101 NORTH AND EAST SIDES
Correction
Partial Correction
07/24/2006
Footing support (IRC) EXCLUDES STOOPS AND GRADE BEAM RM 100 FOOTING APPROVED
Footing Inspection - Commercial Failed 07/25/2006
Correction
Partial Correction
07/25/2006
Footing support (IRC) PER CHANGES ON SHOP DRAWINGS - SEND CHANGES TO OFFICE RM 101 NORTH AND EAST SIDES
Correction
Partial Correction
07/25/2006
Footing support (IRC) EXCLUDES AND GRADE BEAM RM 100 FOOTING APPROVED
Correction
Partial Correction
07/25/2006
Footing support (IRC) RM 101 - EXTERIOR FOOTING PENDING SHOP DRAWING APPROVAL RM 101-100 STOOP BOX INSTALLATION INSTALLED PER PLANS
Underslab Plumbing Inspection - Commercial Not Ready 07/28/2006
Correction
Corrective Action Required
07/28/2006
None NOT READY
Underslab Plumbing Inspection - Commercial Passed 07/31/2006
Correction
Resolved
07/31/2006
None INSIDE OF BUILDING WALLS - AN UNDERGROUND PLUMBING WILL NEED TO BE CALLED IN LATER
Gas Piping Inspection - Commercial Passed 07/31/2006
Gas Service Inspection - Commercial Passed 07/31/2006
Rough Plumbing Inspection - Commercial Passed 09/07/2006
Correction
Resolved
09/07/2006
None IN WALL - PLUMBING AND VENT APPROVED
Above Ceiling Inspection Passed 10/10/2006
Correction
Resolved
10/10/2006
None OK TO COVER
Occupancy Inspection - Codes Commercial Passed 11/17/2006
Correction
Resolved
11/17/2006
Receive Fire Department approval SEE SEPERATE COVER
Correction
Resolved
11/17/2006
Receive Public Works Approval SEE SEPERATE COVER
Correction
Resolved
11/17/2006
None C OF O
Footing Inspection - Commercial Passed 11/21/2006
Correction
Resolved
11/21/2006
Footing support (IRC) PER CHANGES ON SHOP DRAWINGS - SEND CHANGES TO OFFICE RM 101 NORTH AND EAST SIDES
Correction
Resolved
11/21/2006
Footing support (IRC) EXCLUDES AND GRADE BEAM RM 100 FOOTING APPROVED
Correction
Resolved
11/21/2006
Footing support (IRC) RM 101 - EXTERIOR FOOTING PENDING SHOP DRAWING APPROVAL RM 101-100 STOOP BOX INSTALLATION INSTALLED PER PLANS
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home