Permit Application Status

B0600738


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
B0600738
Building Permit - Commercial
Certificate of Occupancy
PARK RIDGE COMMUNITY IMPROVEMENT DIST
NEW OTHER
PARK RIDGE POOL HOUSE
05/10/2006
08/02/2006
01/29/2007
10/09/2007
Locations
Contacts
ARCHER ENGINEERS, Address:3731 NE TROON DR  
CAPITAL CONSTRUCTION SERVICES, Address:2642 NE HAGAN RD  
CLEARLINE PLUMBING, Address:14922 KNORPP RD  
BLUE SPRINGS ELECTRICAL, Address:3402 LAKESHORE DR  
DAVIDSON DESIGN GROUP, Address:11301STRANG LINE ROAD  
UNITED HEATING & COOLING, Address:301 DUCK RD  
PARK RIDGE COMMUNITY IMPROVEMENT DIST, Address:3215 NE CARNEGIE DR  
PARK RIDGE COMMUNITY IMPROVEMENT DIST, Address:3170 NE CARNEGIE DR STE 400  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 01/28/2007 10/29/2010
Correction

Codes Administration - The project cost has not been provided.
Correction

Codes Administration - LSCO Section 7-1011 - Fencing. The area which a swiming pool, sauna, hot tub, or jacuzzi is located shall be entirely enclosed and separated from adjoining property by a protective fence or other permanent structure not less than four (4) feet in height, measured from grade. The enclosure shall be so constructed that a sphere six (6) inches in diamter cannot pass through. Fence posts shall be decay or corrosion-resistant and shall be set in concrete bases. Such protective enclosure shall be provided with gates equipped with self-closing and self-latchig devices placed at the top of the gate; provided, however, that above-grade structures of four (4) feet or greater in height that are equipped with a ladder that can manually be lifted and locked shall not be required to have a protective enclosure. Said ladder shall be locked when the swimming pool, hot tub sauna or jacuzzi is not attended.
Correction

Codes Administration - The plumbing riser diagram shows water being ran to WH-1 which is an electric wall heater.
Correction

Codes Administration - The water piping plans show a line being ran to the pool.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Codes Administration - 2003 IBC 1004.1 - Design occupant load. In determining means of egress requirements, the number of occupants for whom meansof egress facilities shall be provided shall be established by the largest number computed in accordance with Sections 1004.1.1 through 1004.1.3.
Correction

Codes Administration - 2003 IBC 1014.1 - Exit or exit access doorways required. Two exits or exit access doorways from any space shall be provided where one of the following conditions exists: 1. The occupant load of the space exceeds the value in Table 1014.1. 2. The common path of egress travel exceeds the limitations of Section 1013.3. 3. Where required by Sections 1014.3, 1014.4 and 1014.5.
Correction

Codes Administration - LSCO 7-1012 - Steps or ladders. Two (2) or more means of egress in the form of steps or ladders shall be provided for all swimming pools. At least one (1) such means of egress shall be located on a side of the pool at both the deep end and shallow end of the pool. Treads of steps and ladders shall be constructed of nonslip material and at least three (3) inches wide for their full length. Steps and ladders shall have a handrail on both sides.
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

CA - LSCO Chapter 7, Section 7-1018 - Every swimming pool shall be equipped with one (1) or more throwing ring buoys not more than fifteen (15) inches in diameter and having sixty (60) feet of three-sixteenths-inch manila line attached, and one (1) or more light but strong poles with blunt ends and not less than twelve (12) feet in length, for making reach assists or rescues.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

All proposed hose bibb connections must have an approved (vacuum breaker) backflow preventer.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $162.29 $162.29 Paid 08/02/2006
89 Sewer Tap Fees $150.00 $150.00 Paid 08/02/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection Partial 08/03/2006
Correction
Partial Correction
08/03/2006
None APPROVED TO POOL HOUSE. CONNECTION AT POOL HOUSE NOT COMPLETE. EXPOSE FOR SUBSEQUENT INSPECTION.
Sewer Service Inspection - Commercial Request Complete 8/3/2006 8/3/2006 08/03/2006
Water Service Inspection Partial 08/10/2006
Correction
Partial Correction
08/10/2006
None APPROVED FROM TEE AT CLUBHOUSE TO UNDER ENTRY OF POOL HOUSE. COMMON METER WITH CLUBHOUSE. PIPE AT POOLHOUSE TO BE EXPOSED FOR INSPECTION OF CONNECTION AT LATER DATE.
Water Service Inspection - Commercial Request Complete 8/10/2006 8/10/2006 08/10/2006
Underground Electrical Inspection - Commercial Partial 09/25/2006
Correction
Partial Correction
09/25/2006
SITE LIGHTING CONDUITS SERVING (5) POLE LIGHTS APPROVED TO COVER. LIGHT BASES NOT YET INSPECTED
Underground Electrical Inspection - Commercial Request Complete 9/25/2006 9/25/2006 09/25/2006
Underground Electrical Inspection - Commercial Partial 09/27/2006
Correction
Partial Correction
09/27/2006
SITE LIGHTING CONDUITS SERVING (5) POLE LIGHTS APPROVED TO COVER. 3 NORTH POLES APPROVED TO COVER
Miscellaneous Inspection Failed 10/09/2006
Correction
Corrective Action Required
10/09/2006
Premises Identification (IRC) PROPERTY MUST BE IDENTIFIABLE FROM STREET
Footing Inspection - Commercial Partial 10/09/2006
Correction
Partial Correction
10/09/2006
None FOOTINGS APPROVED TO POUR. PIER NOT READY
Underground Electrical Inspection - Commercial Partial 11/01/2006
Correction
Partial Correction
11/01/2006
SITE LIGHTING CONDUITS SERVING (5) POLE LIGHTS APPROVED TO COVER. ALL POLES APPROVED TO COVER
Underground Electrical Inspection - Commercial Request Complete 11/1/2006 11/1/2006 11/01/2006
Miscellaneous Inspection Failed 11/13/2006
Correction
Corrective Action Required
11/13/2006
Premises Identification (IRC) PROPERTY MUST BE IDENTIFIABLE FROM STREET NO FURTHER INSPECTIONS UNTIL COMPLIANT 2ND NOTICE
Underslab Plumbing Inspection - Commercial Passed 11/13/2006
Pool Steel/Bonding - Commercial Partial 11/15/2006
Correction
Partial Correction
11/15/2006
LIGHT NICHES (4) LIGHT NICHE BONDINGS APPROVED.
Miscellaneous Inspection Passed 12/04/2006
Correction
Resolved
12/04/2006
Premises Identification (IRC)
Footing Inspection - Commercial Passed 12/04/2006
Correction
Resolved
12/04/2006
None
Piers/Caissons Inspection - Commercial Passed 12/04/2006
All Rough Inspection - Commercial Failed 12/28/2006
Correction
Corrective Action Required
12/28/2006
PROVIDE ACCESS TO ABOVE SOFFIT PROVIDE ACCESS FOR INSPECTION
Correction
Corrective Action Required
12/28/2006
WATER PIPING INCOMPLETE
Correction
Corrective Action Required
12/28/2006
None DO NOT INSULATE DO NOT ROCK
Correction
Corrective Action Required
12/28/2006
Roof Framing (Details) (IRC) SUPPORT HIP RAFTERS AT RIDGE Attic Area
Correction
Corrective Action Required
12/28/2006
Fireblocking (IRC) FIRE BLOCK TOP PLATES THROUGHOUT
Correction
Corrective Action Required
12/28/2006
Bathroom ventilation (IRC) EXHAUST FANS TO EXHAUST TO EXTERIOR Restroom
Correction
Corrective Action Required
12/28/2006
Water/DWV Preotection Against Physical Damage (IRC) PROVIDE NAIL GUARDS AND BOCA PLATES THROUGHOUT
Correction
Corrective Action Required
12/28/2006
Flashings and Sealing (IRC) PROVIDE PIPE BOOTS Roof
Correction
Corrective Action Required
12/28/2006
Foundation Anchor Bolts (IRC) PROVIDE FOUNDATION ANCHOR BOLTS THROUGHOUT
Electrical Service Inspection Passed 12/28/2006
Electrical Service Inspection Failed 01/24/2007
Correction
Corrective Action Required
01/24/2007
PROVIDE PANEL COVER
Electrical Service Inspection Passed 01/26/2007
Correction
Resolved
01/26/2007
PROVIDE PANEL COVER
All Rough Inspection - Commercial Failed 02/23/2007
Correction
Resolved
02/23/2007
Foundation Anchor Bolts (IRC)
Correction
Resolved
02/23/2007
Flashings and Sealing (IRC)
Correction
Corrective Action Required
02/23/2007
Water/DWV Preotection Against Physical Damage (IRC) PROVIDE NAIL GUARDS AND BOCA PLATES THROUGHOUT
Correction
Resolved
02/23/2007
Bathroom ventilation (IRC)
Correction
Resolved
02/23/2007
Fireblocking (IRC)
Correction
Corrective Action Required
02/23/2007
Roof Framing (Details) (IRC) SUPPORT HIP RAFTERS AT RIDGE Attic Area
Correction
Partial Correction
02/23/2007
None OK TO INSULATE DO NOT ROCK
Correction
Resolved
02/23/2007
WATER PIPING INCOMPLETE
Correction
Corrective Action Required
02/23/2007
Wiring Installation and Support (IRC) 1- SECURE #10 ROMEX BENEATH BOX TO STRUCTURE WITHIN 8" OF BOX 2- BOND BOX PUMP ROOM AT RELAY BOX
Correction
Corrective Action Required
02/23/2007
Stud Drilling and Notching (IRC) REPAIR/REPLACE OVERNOTCHED STUD AT RELAY BOX CONDUIT (ADDING ADJACENT STUD SIDEWAYS WOULD BE SUFFICIENT) PUMP ROOM
Correction
Corrective Action Required
02/23/2007
CAN LIGHT RATING PROVIDE VERIFICATION THAT RECESSED CAN LIGHTS IN CANOPY ARE RATED FOR INSULATION CONTACT. CANOPY
All Rough Inspection - Commercial Failed 03/01/2007
Correction
Corrective Action Required
03/01/2007
Water/DWV Preotection Against Physical Damage (IRC) PROVIDE NAIL GUARDS AND BOCA PLATES THROUGHOUT
Correction
Resolved
03/01/2007
Roof Framing (Details) (IRC)
Correction
Partial Correction
03/01/2007
None OK TO INSULATE OK TO ROCK CONTINGENT UPON PROVIDING BOCA PLATES AT REQUIRED LOCATIONS. (PHOTOS ARE ACCEPTABLE)
Correction
Resolved
03/01/2007
PROVIDE ACCESS TO ABOVE SOFFIT
Correction
Resolved
03/01/2007
CAN LIGHT RATING
Correction
Resolved
03/01/2007
Stud Drilling and Notching (IRC)
Correction
Resolved
03/01/2007
Wiring Installation and Support (IRC)
Pool Steel/Bonding - Commercial Passed 03/20/2007
Correction
Resolved
03/20/2007
LIGHT NICHES (4) LIGHT NICHE BONDINGS APPROVED.
Correction
Resolved
03/20/2007
DECK DECK BONDING APPROVED. 3 ENTRY HANDRAILS - NO OTHER BONDED DEVICES
Underground Electrical Inspection - Commercial Passed 03/20/2007
Correction
Resolved
03/20/2007
SITE LIGHTING CONDUITS SERVING (5) POLE LIGHTS APPROVED TO COVER. ALL POLES APPROVED TO COVER
Correction
Resolved
03/20/2007
POOL AREA LIGHTING CONDUITS SERVING LIGHTS AT POOL PERIMETER APPROVED
All Rough Inspection - Commercial Passed 04/30/2007
Correction
Resolved
04/30/2007
Water/DWV Preotection Against Physical Damage (IRC)
Correction
Resolved
04/30/2007
None OK TO INSULATE OK TO ROCK
Water Service Inspection Passed 06/01/2007
Correction
Resolved
06/01/2007
None
Occupancy Inspection - Codes Commercial Failed 06/01/2007
Correction
Corrective Action Required
06/01/2007
GATE TO BE SELF-CLOSING, SELF LATCHING
Correction
Corrective Action Required
06/01/2007
PROVIDE NO-SMOKING SIGNAGE
Correction
Corrective Action Required
06/01/2007
Through Penetrations (IRC) CAULK/SEAL AROUND GFCI'S IN STUCCO
Correction
Corrective Action Required
06/01/2007
BACKFLOW DRAIN PIPE BACKFLOW PREVENTER DRAIN TO FLOOR DRAIN. UNCOVER FLOOR DRAIN PUMP ROOM
Correction
Resolved
06/01/2007
30 DAY TCO
Correction
Corrective Action Required
06/01/2007
Receive Water Utilities Approval UNDER SEPARATE COVER
Correction
Corrective Action Required
06/01/2007
Receive Public Works Approval UNDER SEPARATE COVER
Correction
Partial Correction
06/01/2007
Receive Planning & Development Approval OK FOR TCO PENDING CODES APPROVAL PER TOM SCANNELL UNDER SEPARATE COVER
Correction
Resolved
06/01/2007
Receive Fire Department approval
Sewer Service Inspection Passed 06/01/2007
Correction
Resolved
06/01/2007
None
Occupancy Inspection - Codes Commercial Failed 09/28/2007
Correction
Resolved
09/28/2007
Receive Planning & Development Approval
Correction
Resolved
09/28/2007
GATE TO BE SELF-CLOSING, SELF LATCHING
Correction
Resolved
09/28/2007
PROVIDE NO-SMOKING SIGNAGE
Correction
Resolved
09/28/2007
Through Penetrations (IRC)
Correction
Resolved
09/28/2007
BACKFLOW DRAIN
Occupancy Inspection - Codes Commercial Passed 10/08/2007
Correction
Resolved
10/08/2007
Receive Public Works Approval
Correction
Resolved
10/08/2007
Receive Water Utilities Approval
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home