Summary
B0600427
Building Permit - Commercial
Certificate of Occupancy
PARK RIDGE COMMUNITY IMPROVEMENT DIST
NEW COMMERCIAL
HOUSE CONVERSION TO CLUBHOUSE
03/27/2006
06/01/2006
03/25/2008
10/01/2007
Locations
Contacts
DAVIDSON DESIGN GROUP, Address:11301STRANG LINE ROAD  
CAPITAL CONSTRUCTION SERVICES, Address:2642 NE HAGAN RD  
PARK RIDGE COMMUNITY IMPROVEMENT DIST, Address:3215 NE CARNEGIE DR  
PARK RIDGE COMMUNITY IMPROVEMENT DIST, Address:3170 NE CARNEGIE DR STE 400  
Reviews
Review Type Outcome Est. Completion Date Completed
Internal Plan Review (Res) Approved 11/28/2006 10/29/2010
Correction

Codes Administration - 2003 IBC 1008.1.5 - Landings at doors. Landings shall have a width not less than the width of the stairway or the door, whichever is the greater. Doors in the fully open position shall not reduce a required dimension by more than 7 inches (178 mm). When the landing serves an occupant load of 50 or more, doors in any position shall not reduce the landings to less than one-half its required width. Landings shall have a length measured in the direction of travel of not less than 44 inches (1118 mm).
Correction

Codes Administration - 2003 IBC 1008.1.4 - Floor elevation. There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit veritical in 12 units horizontal (2-percent slope).
Correction

Codes Administration - 2003 IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be proivided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Exit access corridors, passageways and aisles in rooms and spaces which require two or more means of egress. 2. Exit access corridors and exit stairways locate in buildings required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1023.1, in buildings required to have two or more exits. 5. The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702.
Correction

Codes Administration - 2003 IBC 1009.3 - Stair treads and risers. Stair riser heights shall be 7 inches (178 mm) maximum and 4 inches (102 mm) minimum. Stair tread depths shall be 11 inches (279 mm) minimum. The riser height shall be measured vertically between the leading edges of adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 0.375 inch 99.5 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 0.375 inch (9.5 mm). Winder treads shall have a minimum tread depth of 11 inches (279 mm) measured at a right angle to the tread's leading edge at a point 12 inches (305 mm) fron the side where the treads are narrower and a minimum tread depth of 10 inches (254 mm). The greatest winder tread depth at the 12 inch (305 mm) walk line within any flight of stairs shall not exceed the smallest by more than 0.375 inch (9.5 mm).
Correction

Codes Administration - 2003 IBC 1012.1 - Where required. Guards shall be located along open-sided walking surfaces, mezzanines, industrial equipment platforms, stairways, ramps and landings which are located more than 30 inches (762 mm) above the floor or grade below. Guards shall be adequate in strength and attachment in accordance with Section 1607.7. Guards shall also be located along glazed sides of stairways, ramps and landings that are located more than 30 inches (762 mm) above the floor or grade below where the glazing provided does not meet the strength and attachment requirements in Section 1607.7. In addition, guards are required at retaining walls over 30" above grade when walking surfaces are within ten (10) feet of the high side of the retaining wall. (As amended by the City of Lee's Summit)
Correction

Codes Administration - 2003 IBC 1109.4 - Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible in accordance with ICC A117.1.
Correction

Codes Administration - 2003 IBC 302.1.1.1 - Separation. Where Table 302.1.1 requires a fire-resistance-rated separation, the incidental use area shall be separated fron the remainder of the building with a fire barrier. Where Table 302.1.1 permits an automatic fire-extinguishing system without a fire barrier, the incidential use area shall be separated by construction capable of resisting the passage of smoke. The partitions shall extend fron the floor to the underside of the fire-resistance-rated floor/ceiling assembly or fire-resistance-rated roof/ceiling assembly or to the underside of the floor or roof deck above. Doors shall be self-closing or automatic-closing upon detection of smoke. Doors shall not have air transfer openings and shall not be undercut in excess of the clearance permitted in accordance with NFPA 80.
Correction

Fire Department- Egress doors shall be readily openable from the egress side without the use of akey or special knowledge or effort. Exit doors shall not be locked, chained, barred, latched or otherwise rendered unusable. All locking devises shall be of an approved type.
Correction

Fire Department. Construction documents for fire protection systems shall be submitted for review and approval prior to system installation. The plans and specifications shall bear a State of Missouri licensed engineers seal. This includes fire sprinkler systems, grease hood and duct suppression systems as well as other fire suppression systems.
Correction

Fire Department: Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service main and all other fire protection systems and appurteances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the code official. The code official shall be notified before any required acceptance testing. NOTE: Acceptance testing shall be scheduled at least 48 hours in advance by calling (816) 969-1300.
Correction

Fire Department- IFC 1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent.
Correction

Codes Administration - The project cost has not been provided. This amount is required for permit fee calculation.
Correction

Codes Administration - A analysis of the structural systems was not provided with the permit application.
Correction

Codes Administration - A site plan has not been provided for this project.
Correction

Codes Administration - The plans indicate that there is an existing one-hour fire separation between the garage and the rest of the structure. If the wall was constructed to the residential requirements for separation between a U and R-1 occupancy it does not meet the requirements of a one-hour fire-resistive assembly as it will only have 5/8 inch type x gypsum board on the garage and an unlisted door. This is also true of the floor/ceiling above between the garage and the proposes office space.
Correction

Codes Administration - The plans show the storage area in the lower level as being separated with a one-hour fire-resistive assembly. The plans do not indicate how it is being separated from the space above.
Correction

Codes Administration - The plans only indicate hardware types on a portion of the doors.
Correction

Codes Administration - The permit application does not indicate how this facility is to be used.
Correction

Codes Administration - The secod floor of this space is not shown as accessible.
Correction

Codes Administration - Per the Lee's Summit Design and Construction Manual, a reduced-pressure principle backflow assembly is required on the domestic service of all commercial buildings.
Correction

Codes Administration - The plans indicate that the door from Serving Area 109 is an egress door. This existing door does not meet the requirements for door swing or clear width.
Correction

Fire Department- The revised drawings show the public hydrant at the street being removed and a private hydrant installed. The backflow valve and main going to the hydrant shall be a minimum of 6".
Correction

CA - The disposal of demolition waste is regulated by the Department of Natural Resources under Chapter 260 RSMO. Such waste, in types and quantities established by the department, shall be taken to a demolition landfill or a sanitary landfill for disposal.
Correction

CA - A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit.
Correction

CA - The occupancy and or final inspection shall be scheduled with the Codes Administration Department and requires a minimum of two (2) working days notice. Codes Administration will contact the appropriate city departments and will notify the applicant of the date and time the inspection will be performed.
Correction

CA - Any deviation from the approved plans shall be approved by the City of Lee's Summit. This shall include but is not limited to building layout, facilities provided, building materials and equipment, finishes used, landscaping and site improvements. Information about the changes shall be submitted to the Codes Administration Department for review and a determination will be provided within five (5) working days.
Correction

CA - The Final Development Plan must be approved prior to issuing full building permits.
Correction

Fire Department;A site plan depicting proposed fire apparatus access, location of fire lanes and parking areas and for fire hydrant locations shall be submitted to the fire department for review and approval prior to construction.
Correction

Fire Department; New and existing buildings shall have approved address numbers, building numbers, placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background.
Correction

Fire Department; The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly.
Correction

Fire Department; Portable fire extinguishers shall be installed in occupancies and locations as set forth in the IFC Sec. 906 and as required by the Code Offical. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
Correction

Fire Department; Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Documents shall bear a State of Missouri architect/engineers seal..Construction documents shall include, but not be limited to, all of the following: 1. A floor plan. 2. Locations of alarm-initiating and notification appli- ances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing informa- tion for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions.
Correction

CA - LSCO Chapter7, Section 117 - Materials, equipment, and devices approved by the building official shall be constructed and installed in accordance with such approval.
Correction

CA - LSCO 7-134 - Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Permits for exterior work, i.e., walls, fences, decks, patios, patio covers and similar type work requiring permits, as well as permits for residential room additions and remodels shall be limited to 180 days duration. Permits for other new construction shall be limited to one-year duration. The building official official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.
Correction

CA - LSCO 7-162 - It shall be the duty of the holder of the permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspection of such work for any inspections that are required by this code. Inspection requests shall be made in advance and in accordance with the most current written policies of the Codes Administration Department.
Correction

CA - LSCO7-168 - The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.
Correction

Codes Administration - 2003 IMC 501.2 - Outdoor discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space.
Correction

P & D - Sign permits must be obtained for all signs prior to installation. All signs shall comply with the sign requirements outlined in the UDO, Article 13.
Correction

CA - Erosion control devices shall be installed and maintained throughout the construction process in accordance with the City of Lee's Summit Design and Construction Manual. Failure to install or maintain erosion control devices may result in inspections not being performed, stop work orders being issued or court charges/action may be taken.
Correction

CA - No merchandise, stock, interior furnishings or supplies shall be placed in this facility without approval from the City of Lee's Summit.
Correction

CA - Each structure shall have the address of that structure visibly posted on the jobsite throughtout the construction process.
Fees
Paid Fees Amount Paid Owing Date Paid
0120 Building Permit Fee $902.50 $902.50 Paid 06/01/2006
84 Water Meters $625.00 $625.00 Paid 06/01/2006
85 Water Taps $13,670.00 $13,670.00 Paid 06/01/2006
89 Sewer Tap Fees $990.00 $990.00 Paid 06/01/2006
Right of Way Permit $35.00 $35.00 Paid 06/01/2006
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Failed 06/21/2006
Correction
Corrective Action Required
06/21/2006
Premises Identification (IRC) PROPERTY MUST BE IDENTIFIABLE FROM STREET.
Underslab Plumbing Inspection - Commercial Passed 06/21/2006
Underground Plumbing Inspection - Commercial Request Complete 7/19/2006 7/20/2006 07/20/2006
Sewer Service Inspection Passed 08/02/2006
Sewer Service Inspection - Commercial Request Complete 8/2/2006 8/2/2006 08/02/2006
Water Service Inspection Partial 08/10/2006
Correction
Partial Correction
08/10/2006
None APPROVED FROM TEE AT CLUBHOUSE TO 60' TOWARDS MAIN. DO NOT COVER TEE OR PIPE THROUGH FOUNDATION.
Water Service Inspection Passed 08/11/2006
Correction
Resolved
08/11/2006
None
Water Service Inspection - Commercial Request Complete 8/11/2006 8/11/2006 08/11/2006
All Rough Inspection - Commercial Failed 09/19/2006
Correction
Partial Correction
09/19/2006
None OK TO INSULATE DO NOT ROCK
Correction
Corrective Action Required
09/19/2006
COMMENTS 1- CONNECT MAIN SYSTEM SERVICE GROUND CONDUCTOR TO WATER LINE 2- SCHEDULE ELECTRICAL SERVICE INSPECTION AT A TIME WHEN ELECTRICAL CONTRACTOR IS AVAILABLE. CALL OFFICE BEFORE 8:30am TO COORDINATE Basement STORAGE AREA
Correction
Corrective Action Required
09/19/2006
Fireblocking (IRC) FIRE BLOCK AT CEILING LINE Basement LIVING ROOM
Correction
Corrective Action Required
09/19/2006
Drilling & Notching (Engineered) (IRC) PROVIDE SEALED ENGINEER'S APPROVAL OR FIX FOR NOTCHED LAM BEAM Basement POOL ROOM
Correction
Corrective Action Required
09/19/2006
Metal Boxes (grounding) (IRC) GROUND METAL J-BOX IN CEILING Basement BILLIARDS ROOM
Correction
Corrective Action Required
09/19/2006
RESTROOMS (CONTINUED) 4- PROVIDE GRAB BAR REINFORCEMENT 5- PROVIDE HEADERS ABOVE DOORS 6- PROVIDE EXHAUST FAN CUT SHEETS TO VERIFY BACKDRAFT PROTECTION 1ST & 2ND FLOORS
Correction
Corrective Action Required
09/19/2006
RESTROOMS 1- FIRE BLOCK ALL: RETURN AIR PENETRATIONS, TOP PLATES, BOTTOM PLATES, HORIZONTAL-VERTICAL SPACES AT CEILING LINES 2- ISOLATE JUNCTION BOX FROM RETURN AIR PATH (BASEMENT) 3- PROVIDE NAIL PROTECTION AT ALL PLUMBING W/IN 1.5" OF NAILING SURFACE. 1ST & 2ND FLOORS
All Rough Inspection - Commercial Passed 09/21/2006
Correction
Resolved
09/21/2006
RESTROOMS
Correction
Resolved
09/21/2006
RESTROOMS (CONTINUED)
Correction
Resolved
09/21/2006
Metal Boxes (grounding) (IRC)
Correction
Resolved
09/21/2006
Drilling & Notching (Engineered) (IRC)
Correction
Resolved
09/21/2006
Fireblocking (IRC)
Correction
Resolved
09/21/2006
COMMENTS Basement
Correction
Resolved
09/21/2006
None OK TO INSULATE OK TO ROCK
Miscellaneous Inspection Passed 11/30/2006
Correction
Resolved
11/30/2006
Premises Identification (IRC) MOVED TO FINAL
Occupancy Inspection - Codes Commercial Failed 11/30/2006
Correction
Corrective Action Required
11/30/2006
None DO NOT OCCUPY OK TO FURNISH
Correction
Corrective Action Required
11/30/2006
FIRE BLOCKING FIRE BLOCK ALL FLOOR-TO-FLOOR AND CEILING-TO-ATTIC PENETRATIONS INCLUDING, BUT NOT LIMITED TO: - WEST OFFICE CLOSET - UPPER NORTH MIDDLE BEDROOM CLOSET VARIES
Correction
Corrective Action Required
11/30/2006
INTERIOR ELECTRIC ALL KITCHEN RECEPTACLES MUST BE GFCI PROTECTED Kitchen
Correction
Corrective Action Required
11/30/2006
INTERIOR STAIRS & HANDRAILS 1- STAIRS FROM CORRIDOR INTO ROOM TO HAVE MAX. 7-3/4" RISE, MIN. 11" TREADS & HANDRAILS WITH EXTENSIONS 2- STAIRS FROM STORAGE ROOM INTO BASEMENT REQUIRE HANDRAILS WITH EXTENSIONS NOTE: ALL HANDRAILS MUST RETURN TO A WALL OR TERMINATE AT A POST MAIN LEVEL EAST STORAGE
Correction
Corrective Action Required
11/30/2006
EXTERIOR ELECTRICAL 1- GFCI RECPTACLES AT MAIN LEVEL REAR PATIO NON-FUNCTIONAL 2- SECURE A/C CONDUITS TO STRUCTURE
Correction
Corrective Action Required
11/30/2006
Through Penetrations (IRC) CAULK/SEAL ALL EXTERIOR PENETRATIONS EXTERIOR
Correction
Corrective Action Required
11/30/2006
EXTERIOR STEPS & HANDRAILS 1- FRONT STEPS TO BE MAX. 7-3/4" HIGH & CONSISTENT WITHIN 3/8" & REQUIRE HANDRAILS 2- PROVIDE HANDRAIL AT REAR RAMP 3- ALL HANDRAILS (IN & OUT) TO HAVE EXTENSIONS AT TOP & BOTTOM.
Correction
Corrective Action Required
11/30/2006
Grading (IRC) PROVIDE FINAL GRADE, SOD & SPLASHBLOCKS EXTERIOR
Correction
Corrective Action Required
11/30/2006
Receive Water Utilities Approval UNDER SEPARATE COVER
Correction
Corrective Action Required
11/30/2006
Receive Public Works Approval UNDER SEPARATE COVER
Correction
Corrective Action Required
11/30/2006
Receive Planning & Development Approval UNDER SEPARATE COVER
Correction
Resolved
11/30/2006
Receive Fire Department approval
Occupancy Inspection - Codes Commercial Failed 12/05/2006
Correction
Resolved
12/05/2006
Receive Water Utilities Approval
Occupancy Inspection - Codes Commercial Failed 01/04/2007
Correction
Corrective Action Required
01/04/2007
Receive Public Works Approval UNDER SEPARATE COVER NO ISSUES PRESENTED
Correction
Resolved
01/04/2007
EXTERIOR STEPS & HANDRAILS
Correction
Corrective Action Required
01/04/2007
Through Penetrations (IRC) CAULK/SEAL ALL EXTERIOR PENETRATIONS EXTERIOR
Correction
Resolved
01/04/2007
EXTERIOR ELECTRICAL SECURE A/C CONDUITS TO STRUCTURE
Correction
Resolved
01/04/2007
INTERIOR STAIRS & HANDRAILS
Correction
Resolved
01/04/2007
INTERIOR ELECTRIC
Correction
Resolved
01/04/2007
FIRE BLOCKING
Correction
Resolved
01/04/2007
None 90 DAY TCO
Occupancy Inspection - Codes Commercial Failed 04/12/2007
Correction
Corrective Action Required
04/12/2007
Receive Planning & Development Approval UNDER SEPARATE COVER
Correction
Resolved
04/12/2007
Receive Public Works Approval
Correction
Resolved
04/12/2007
Grading (IRC)
Correction
Resolved
04/12/2007
Through Penetrations (IRC)
Occupancy Inspection - Codes Commercial Passed 09/28/2007
Correction
Resolved
09/28/2007
Receive Planning & Development Approval
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home